Literature DB >> 19226017

Assessment of accuracy of acetabular cup orientation in CT-free navigated total hip arthroplasty.

Shigeo Fukunishi1, Tomokazu Fukui, Fumiaki Imamura, Shoji Nishio.   

Abstract

We have used the Orthopilot (Aesculap AG, Tuttlingen, Germany) computed tomography (CT)-free navigation system to ensure accurate and reproducible acetabular cup orientation. In this system, cup orientation is assessed with respect to bony configuration as determined by palpation of the anatomical landmarks (the bilateral anterosuperior iliac spines and the upper margin of the pubic symphysis). In this study, intraoperative cup orientation as presented by the OrthoPilot navigation system was compared with the value obtained through postoperative radiological assessment using CT Digital Imaging and Communications in Medicine (DICOM) data and Medical Image Processing, Analysis, and Visualization (MIPAV; National Institutes of Health, US Department of Health and Human Services, Bethesda, Maryland). Intra- and postoperative results obtained from 27 consecutive navigated total hip arthroplasties (THAs) were analyzed. For cup positioning, the desired inclination and anteversion angles were set within the "safe zone" proposed by Lewinnek. In the intraoperative evaluation, the mean inclination angle as determined by the navigation system was 43.5 degrees +/- 2.17 degrees (range, 39.9 degrees to 46.6 degrees ) after the final implantation. In contrast, the mean inclination angle determined by postoperative calculation using MIPAV was 44.9 +/- 3.3 degrees (range, 38.1 degrees to 55.0 degrees ). A discrepancy of >5 degrees was observed in only 1 hip. For the anteversion, the mean intra- and postoperative values were 11.1 degrees +/- 5.6 degrees (range, 0 degrees to 17.8 degrees ) and 13.5 degrees +/- 5.9 degrees (range, 5.1 degrees to 21.6 degrees ), respectively. Again, a discrepancy of >5 degrees was observed in 1 case. Mean differences between the intra- and postoperative values were 1.9 degrees +/- 1.9 degrees and 2.6 degrees +/- 1.6 degrees for inclination and anteversion, respectively. A good agreement between the intraoperative values presented by the navigation system and those in the postoperative CT evaluation was observed, and the validity of this navigation system was confirmed.

Entities:  

Mesh:

Year:  2008        PMID: 19226017

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  10 in total

1.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Accuracy of computer navigation for acetabular component placement in THA.

Authors:  James A Ryan; Amir A Jamali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2009-07-24       Impact factor: 4.176

3.  Accuracy of combined anteversion in image-free navigated total hip arthroplasty: stem-first or cup-first technique?

Authors:  Shigeo Fukunishi; Shoji Nishio; Yuki Fujihara; Shohei Okahisa; Yu Takeda; Tomokazu Fukui; Shinichi Yoshiya
Journal:  Int Orthop       Date:  2015-05-07       Impact factor: 3.075

4.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

5.  Accuracy of acetabular cup positioning using imageless navigation.

Authors:  Erik Hohmann; Adam Bryant; Kevin Tetsworth
Journal:  J Orthop Surg Res       Date:  2011-08-10       Impact factor: 2.359

6.  Natural acetabular orientation in arthritic hips.

Authors:  S T Goudie; A H Deakin; K Deep
Journal:  Bone Joint Res       Date:  2015-01       Impact factor: 5.853

7.  Combined anteversion of the total hip arthroplasty implanted with image-free cup navigation and without stem navigation.

Authors:  Shigeo Fukunishi; Tomokazu Fukui; Shoji Nishio; Yuki Fujihara; Shohei Okahisa; Shinichi Yoshiya
Journal:  Orthop Rev (Pavia)       Date:  2012-11-28

8.  Assessment of acetabulum anteversion aligned with the transverse acetabulum ligament: cadaveric study using image-free navigation system.

Authors:  Tomokazu Fukui; Shigeo Fukunishi; Shoji Nishio; Yuki Fujihara; Okahisa Shohei; Shinichi Yoshiya
Journal:  Orthop Rev (Pavia)       Date:  2013-03-19

9.  Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims.

Authors:  Hiroshi Wada; Hajime Mishima; Tomohiro Yoshizawa; Hisashi Sugaya; Tomofumi Nishino; Masashi Yamazaki
Journal:  Open Orthop J       Date:  2016-03-22

10.  Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.

Authors:  Ken Suda; Tomoyuki Ito; Dai Miyasaka; Norio Imai; Izumi Minato; Naoto Endo
Journal:  Springerplus       Date:  2016-06-18
  10 in total