Dose assessment from an online kilovoltage imaging system in radiation therapy.

Ernest K Osei1, Bryan Schaly, Andre Fleck, Paule Charland, Rob Barnett.   

Abstract

We have investigated the dosimetric properties of a commercial kilovoltage cone beam computerised tomography (kV-CBCT) system. The kV-CBCT doses were measured in 16 and 32 cm diameter standard cylindrical Perspex computerised tomography (CT) and Rando anthropomorphic phantoms using 125 kVp and 1.0-2.0 mA s per projection. We also measured skin doses using thermoluminescence dosimeters placed on the skin surfaces of prostate cancer patients undergoing kV-kV image matching for daily set-up. The skin doses from kV-kV image matching of prostate cancer patients on the anterior and lateral skin surfaces ranged from 0.03 +/- 0.01 to 0.64 +/- 0.01 cGy depending on the beam filtration and technique factors employed. The mean doses on the Rando phantom ranged from 3.0 +/- 0.1 to 5.1 +/- 0.3 cGy for full-fan scans and from 3.8 +/- 0.1 to 6.6 +/- 0.2 cGy for half-fan scans using 125 kVp and 2 mA s per projection. The isocentre cone beam dose index (CBDI) in the 16 and 32 cm Perspex phantoms is 4.65 and 1.81 cGy, respectively (using a 0.6 cm(3) Capintec PR06C Farmer chamber) for full-fan scans, and the corresponding normalised CBDIs are 0.72 and 0.28 cGy/100 mA s, respectively. The mean weighted CBDIs are 4.93 and 2.14 cGy, and the normalised weighted CBDIs are 0.76 and 0.33 cGy/100 mA s for the 16 and 32 cm phantoms, respectively (full-fan scans). The normalised weighted CBDI for the half-fan scan is 0.41 cGy/100 mA s for the 32 cm diameter phantom. All measurements of the CBDI using the 0.6 cm(3) Farmer chamber are within 2-5% of measurements taken with the 100 mm CT chamber. The CBDI technique and definitions can be used to benchmark CBCT systems and to provide estimates of imaging doses to patients undergoing on-board imager (OBI)/CBCT image guided radiation therapy.

Entities:  

Mesh:

Year:  2009        PMID: 19225181     DOI: 10.1088/0952-4746/29/1/002

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  7 in total

1.  Risk factors related to interfractional variation in whole pelvic irradiation for locally advanced pelvic malignancies.

Authors:  W S Yoon; D S Yang; J A Lee; S Lee; Y J Park; C Y Kim
Journal:  Strahlenther Onkol       Date:  2012-02-10       Impact factor: 3.621

2.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

3.  Dosimetry challenges for implementing emerging technologies.

Authors:  Fang-Fang Yin; Mark Oldham; Jing Cai; Qiuwen Wu
Journal:  J Phys Conf Ser       Date:  2010

4.  PCXMC cone beam computed tomography dosimetry investigations.

Authors:  Aaron Fetin; Lucy Cartwright; Jonathan Sykes; Alicja Wach
Journal:  Phys Eng Sci Med       Date:  2022-01-24

5.  An evaluation of the stability of image-quality parameters of Varian on-board imaging (OBI) and EPID imaging systems.

Authors:  Dennis N Stanley; Nikos Papanikolaou; Alonso N Gutierrez
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

6.  COMP report: CPQR technical quality control guidelines for accelerator-integrated cone-beam systems for verification imaging.

Authors:  Jean-Pierre Bissonnette
Journal:  J Appl Clin Med Phys       Date:  2018-03-06       Impact factor: 2.102

7.  An evaluation of the stability of image quality parameters of Elekta X-ray volume imager and iViewGT imaging systems.

Authors:  Dennis N Stanley; Karl Rasmussen; Neil Kirby; Nikos Papanikolaou; Alonso N Gutiérrez
Journal:  J Appl Clin Med Phys       Date:  2018-03-09       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.