Literature DB >> 19219815

Bone remodelling in THA: A comparative DXA scan study between conventional implants and a new stemless femoral component. A preliminary report.

C V Albanese1, M Rendine, F De Palma, A Impagliazzo, F Falez, F Postacchini, C Villani, R Passariello, F S Santori.   

Abstract

Periprosthetic bone loss is a major cause for concern in patients undergoing total hip arthroplasty (THA). There are many different factors that may determine the pattern of bone loss and bone remodelling following THA, such as the quality of the bone before the hip replacement, skeletal bone mass at the time of the operation, material and method of fixation and implant design. Recent developments in dual-energy X-ray absorptiometry (DXA) have made it possible to quantify bone mineral density (BMD) to evaluate changes around the prosthesis and to measure bone stock and bone density redistribution after a total hip replacement. In this cross-sectional multicentre clinical study the DXA method was used to compare bone mass after uncemented THA of a custom-made stemless design with five groups of conventional cementless implants (Alloclassic, Mayo, CFP, IPS, ABG). The adaptive bone changes of the proximal femur three years after implantation were evaluated. Periprosthetic BMD was measured in 130 subjects in the seven regions of interest (ROI) based on Gruen zones. Significant differences were found between the stemless implant and the other five groups in zones 1, 4 and 7. The CFP, IPS, and ABG groups showed decreased BMD in ROI 1, and the Mayo, IPS and Alloclassic in ROI 7. An increased BMD in ROI 4 was observed in the Mayo, IPS, ABG and Alloclassic groups. The results of the present study suggest that a conservative stemless implant with complete proximal load transfer produces a homogeneous and more physiological redistribution of bone density, allowing maintenance of proximal periprosthetic bone stock.

Entities:  

Year:  2006        PMID: 19219815     DOI: 10.1177/112070000601603S03

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   1.756


  23 in total

1.  Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study.

Authors:  Matthias Lerch; Annelene von der Haar-Tran; Henning Windhagen; Bernd A Behrens; Patrick Wefstaedt; Christina M Stukenborg-Colsman
Journal:  Int Orthop       Date:  2011-09-21       Impact factor: 3.075

2.  Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesis.

Authors:  Daniel Briem; Michael Schneider; Nicole Bogner; Nadine Botha; Matthias Gebauer; Thorsten Gehrke; Bernd Schwantes
Journal:  Int Orthop       Date:  2010-05-02       Impact factor: 3.075

3.  [Short-stemmed endoprostheses in total hip arthroplasty].

Authors:  J Gulow; R Scholz; G Freiherr von Salis-Soglio
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

4.  Long-term results and bone remodeling after THA with a short, metaphyseal-fitting anatomic cementless stem.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim; Jun-Seok Kang
Journal:  Clin Orthop Relat Res       Date:  2013-10-26       Impact factor: 4.176

5.  Outcome of short versus conventional stem for total hip arthroplasty in the femur with a high cortical index: a five year follow-up prospective multicentre comparative study.

Authors:  Francesco Pogliacomi; Paolo Schiavi; Guido Grappiolo; Francesco Ceccarelli; Enrico Vaienti
Journal:  Int Orthop       Date:  2019-04-24       Impact factor: 3.075

6.  Densitometric evaluation of periprosthetic bone remodeling.

Authors:  Paolo Domenico Parchi; Valentina Cervi; Nicola Piolanti; Gianluca Ciapini; Lorenzo Andreani; Iacopo Castellini; Andrea Poggetti; Michele Lisanti
Journal:  Clin Cases Miner Bone Metab       Date:  2014-09

7.  Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review.

Authors:  Shuang G Yan; Patrick Weber; Arnd Steinbrück; Xingyi Hua; Volkmar Jansson; Florian Schmidutz
Journal:  Int Orthop       Date:  2017-11-27       Impact factor: 3.075

8.  Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances.

Authors:  William Blakeney; Yann Beaulieu; Benjamin Puliero; Marc-Olivier Kiss; Pascal-André Vendittoli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-14       Impact factor: 4.342

9.  Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems: 37 patients followed for 3 years.

Authors:  Carlina V Albanese; Francesco S Santori; Laura Pavan; Ian D Learmonth; Roberto Passariello
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

10.  Perspectives on metaphyseal conservative stems.

Authors:  F Falez; F Casella; G Panegrossi; F Favetti; C Barresi
Journal:  J Orthop Traumatol       Date:  2008-03-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.