Literature DB >> 15876665

Image reconstruction for the circle-and-arc trajectory.

Alexander Katsevich1.   

Abstract

Proposed is an exact shift-invariant filtered backprojection algorithm for the circle-and-arc trajectory. The algorithm has several important features. First, it allows for the circle to be incomplete. Second, axial truncation of the cone beam data is allowed. Third, the length of the arc is determined only by the region of interest and is independent of the size of the entire object. The algorithm is quite flexible and can be used for even more general trajectories that consist of several circular segments and arcs. The algorithm applies also in the case when the circle (or, circles) is complete. A numerical experiment with the clock phantom demonstrated good image quality.

Mesh:

Year:  2005        PMID: 15876665     DOI: 10.1088/0031-9155/50/10/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Exact Weighted-FBP Algorithm for Three-Orthogonal-Circular Scanning Reconstruction.

Authors:  Hongli Hu; Jianzhou Zhang
Journal:  Sensors (Basel)       Date:  2009-06-12       Impact factor: 3.576

2.  Exact reconstruction of volumetric images in reverse helical cone-beam CT.

Authors:  Seungryong Cho; Dan Xia; Charles A Pelizzari; Xiaochuan Pan
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

3.  Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory.

Authors:  Tingliang Zhuang; Joseph Zambelli; Brian Nett; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  Truncation correction for oblique filtering lines.

Authors:  Stefan Hoppe; Joachim Hornegger; Günter Lauritsch; Frank Dennerlein; Frédéric Noo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Image reconstruction in reduced circular sinusoidal cone-beam CT.

Authors:  Dan Xia; Seungryong Cho; Xiaochuan Pan
Journal:  J Xray Sci Technol       Date:  2009       Impact factor: 1.535

6.  Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory.

Authors:  Stefan Hoppe; Joachim Hornegger; Frank Dennerlein; Günter Lauritsch; Frédéric Noo
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-21       Impact factor: 2.924

7.  A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories.

Authors:  M W Jacobson; M D Ketcha; S Capostagno; A Martin; A Uneri; J Goerres; T De Silva; S Reaungamornrat; R Han; A Manbachi; J W Stayman; S Vogt; G Kleinszig; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2018-01-16       Impact factor: 3.609

8.  Line plus arc source trajectories and their R-line coverage for long-object cone-beam imaging with a C-arm system.

Authors:  Zhicong Yu; Adam Wunderlich; Frank Dennerlein; Günter Lauritsch; Frédéric Noo
Journal:  Phys Med Biol       Date:  2011-05-23       Impact factor: 3.609

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.