Literature DB >> 19169917

Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients.

F Holmquist1, K Hansson, F Pasquariello, J Björk, U Nyman.   

Abstract

BACKGROUND: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used.
PURPOSE: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser.
MATERIAL AND METHODS: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR >or=50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 micromol/l from baseline.
RESULTS: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGy x cm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN.
CONCLUSION: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM doses compared with common routine practice, which should be to the benefit of patients at risk of CIN.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19169917     DOI: 10.1080/02841850802657269

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  16 in total

1.  Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Authors:  Maninderpal Kaur Gill; Anushya Vijayananthan; Gnana Kumar; Kasthoori Jayarani; Kwan-Hoong Ng; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2015-08

2.  Individually tailored contrast enhancement in CT pulmonary angiography.

Authors:  Babs M F Hendriks; Madeleine Kok; Casper Mihl; Sebastiaan C A M Bekkers; Joachim E Wildberger; Marco Das
Journal:  Br J Radiol       Date:  2016-01-22       Impact factor: 3.039

3.  Application of intelligent optimal kV scanning technology (CARE kV) in dual-source computed tomography (DSCT) coronary angiography.

Authors:  Jun Zhang; Shaolei Kang; Dan Han; Xiaojie Xie; Yaming Deng
Journal:  Int J Clin Exp Med       Date:  2015-10-15

4.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

5.  High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume.

Authors:  Guang Ming Lu; Song Luo; Felix G Meinel; Andrew D McQuiston; Chang Sheng Zhou; Xiang Kong; Yan E Zhao; Ling Zheng; U Joseph Schoepf; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2014-08-07       Impact factor: 5.315

6.  Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights.

Authors:  Zsolt Szucs-Farkas; Boglarka Megyeri; Andreas Christe; Peter Vock; Johannes T Heverhagen; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

7.  Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol.

Authors:  Chun-Ling Ma; Xiao-Xia Chen; Yu-Xin Lei; Xi-Rong Zhang; Yong-Jun Jia; Xin Tian; Qian Tian
Journal:  Br J Radiol       Date:  2016-03-31       Impact factor: 3.039

8.  Determination of lowest possible contrast volume in computed tomography pulmonary angiography by using pulmonary transit time.

Authors:  Koray Kilic; Gonca Erbas; Murat Ucar; Koray Akkan; Nil Tokgoz; Mehmet Arac; Sedat Isik
Journal:  Jpn J Radiol       Date:  2014-01-05       Impact factor: 2.374

9.  Accuracy of low-dose chest CT in intensive care patients.

Authors:  Joakim Börjesson; Ali Latifi; Ola Friman; Mats O Beckman; Anders Oldner; Fausto Labruto
Journal:  Emerg Radiol       Date:  2010-08-06

10.  Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration.

Authors:  Jae-Yeon Hwang; Ki Seok Choo; Yoon Young Choi; Jin Hyeok Kim; Hwaseong Ryu; Junhee Han; Yong-Woo Kim; Ung Bae Jeon; Kyung Jin Nam
Journal:  Pediatr Radiol       Date:  2017-02-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.