Literature DB >> 19161164

Gradient moment compensated magnetic resonance spectroscopic imaging.

Dong-Hyun Kim1, Meng Gu, Daniel M Spielman.   

Abstract

Spectroscopic imaging applications outside of the brain can suffer from artifacts due to inherent long scan times and susceptibility to motion. A fast spectroscopic imaging sequence has been devised with reduced sensitivity to motion. The sequence uses oscillating readout gradients and acquires k-space data in a spiral out-in fashion, which allows fast k-space coverage. We show that a spiral out-in readout acquisition is characterized by small gradient moments, reducing sensitivity to motion-induced artifacts. Data are acquired comparing the sequence to normal phase encoded spectroscopic imaging and conventional spiral spectroscopic imaging protocols. In addition, in vivo data are acquired from the liver, demonstrating potential usage as a multivoxel fat/water spectroscopic imaging tool. Results indicate that in the presence of motion, ghosting effects are reduced while metabolite signal increases of approximately 10% can be achieved. Copyright 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19161164      PMCID: PMC2835400          DOI: 10.1002/mrm.21832

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Simple analytic spiral K-space algorithm.

Authors:  G H Glover
Journal:  Magn Reson Med       Date:  1999-08       Impact factor: 4.668

2.  Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference.

Authors:  G Helms; A Piringer
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

3.  Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts.

Authors:  G H Glover; C S Law
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  Reversed spiral MR imaging.

Authors:  P Börnert; B Aldefeld; H Eggers
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

5.  Out-and-in spiral spectroscopic imaging in rat brain at 7 T.

Authors:  Bassem Hiba; Bérengère Faure; Laurent Lamalle; Michel Décorps; Anne Ziegler
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

6.  Rapid proton fat-water spectroscopy for the characterization of non-CNS lesions in vivo.

Authors:  Gerard Riedy
Journal:  Clin Imaging       Date:  2003 May-Jun       Impact factor: 1.605

7.  Spiral readout gradients for the reduction of motion artifacts in chemical shift imaging.

Authors:  Dong-Hyun Kim; Elfar Adalsteinsson; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

8.  Measurement and correction of respiration-induced B0 variations in breast 1H MRS at 4 Tesla.

Authors:  Patrick J Bolan; Pierre-Gilles Henry; Eva H Baker; Sina Meisamy; Michael Garwood
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

9.  Effects of physiologic motion of the human brain upon quantitative 1H-MRS: analysis and correction by retro-gating.

Authors:  J Felblinger; R Kreis; C Boesch
Journal:  NMR Biomed       Date:  1998-05       Impact factor: 4.044

10.  On the reliability of quantitative clinical magnetic resonance spectroscopy of the human brain.

Authors:  T Schirmer; D P Auer
Journal:  NMR Biomed       Date:  2000-01       Impact factor: 4.044

View more
  4 in total

Review 1.  Magnetic resonance spectroscopy imaging of the newborn brain--a technical review.

Authors:  Duan Xu; Daniel Vigneron
Journal:  Semin Perinatol       Date:  2010-02       Impact factor: 3.300

2.  Motion correction methods for MRS: experts' consensus recommendations.

Authors:  Ovidiu C Andronesi; Pallab K Bhattacharyya; Wolfgang Bogner; In-Young Choi; Aaron T Hess; Phil Lee; Ernesta M Meintjes; M Dylan Tisdall; Maxim Zaitzev; André van der Kouwe
Journal:  NMR Biomed       Date:  2020-07-20       Impact factor: 4.044

3.  Whole-Slab 3D MR Spectroscopic Imaging of the Human Brain With Spiral-Out-In Sampling at 7T.

Authors:  Morteza Esmaeili; Bernhard Strasser; Wolfgang Bogner; Philipp Moser; Zhe Wang; Ovidiu C Andronesi
Journal:  J Magn Reson Imaging       Date:  2020-11-12       Impact factor: 5.119

4.  An integrated RF-receive/B0-shim array coil boosts performance of whole-brain MR spectroscopic imaging at 7 T.

Authors:  Morteza Esmaeili; Jason Stockmann; Bernhard Strasser; Nicolas Arango; Bijaya Thapa; Zhe Wang; Andre van der Kouwe; Jorg Dietrich; Daniel P Cahill; Tracy T Batchelor; Jacob White; Elfar Adalsteinsson; Lawrence Wald; Ovidiu C Andronesi
Journal:  Sci Rep       Date:  2020-09-14       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.