Literature DB >> 12483406

Clinical validation of simultaneous dual-isotope myocardial scintigraphy.

Pierre Weinmann1, Marc Faraggi, Jean Luc Moretti, Pascal Hannequin.   

Abstract

Simultaneous dual-isotope (rest thallium-201/stress technetium-99m sestamibi) myocardial single-photon emission tomography (SPET) would be an ideal procedure; however, (99m)Tc cross-talk on the (201)Tl window hampers its routine use. Photon energy recovery (PER) is a spectral deconvolution technique validated for scatter and cross-talk removal in phantom studies and a limited series of patients. In this study we aimed to validate the technique in 295 patients within a context of clinical routine practice. Conventional separate rest (201)Tl myocardial SPET data sets were visually compared with simultaneous dual-isotope data sets corrected by PER. Conventional separate rest (201)Tl data sets were identical to dual PER-corrected (201)Tl data sets in 173 (58.6%) patients. As dual PER (201)Tl data sets are corrected for (99m)Tc cross-talk but also for (201)Tl scatter, they were compared with separate rest (201)Tl data sets corrected by PER in the 122 discordant patients. No difference was found in 77 (26.1%) patients. In 26 (8.8%) patients, the difference consisted in the presence of a defect on dual PER (201)Tl data sets only, mirroring an ischaemic defect on (99m)Tc-sestamibi data sets. This difference can be attributed to the influence of stress on the kinetics of (201)Tl injected at rest. In the remaining 19 (6.4%) patients, the difference between separate and simultaneous PER-corrected data sets was scored as mild in 11 and moderate in eight patients and seemed to be related to multiple methodological factors. It is concluded that PER correctly removes (99m)Tc cross-talk. With the addition of an appropriate attenuation correction, the PER technique may allow the routine use of simultaneous dual-isotope myocardial scintigraphy in the near future.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12483406     DOI: 10.1007/s00259-002-0995-y

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  9 in total

Review 1.  Multiplexed imaging in cancer diagnosis: applications and future advances.

Authors:  Hisataka Kobayashi; Michelle R Longmire; Mikako Ogawa; Peter L Choyke; Satomi Kawamoto
Journal:  Lancet Oncol       Date:  2010-03-24       Impact factor: 41.316

2.  Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

Authors:  Simona Ben-Haim; Krzysztof Kacperski; Sharon Hain; Dean Van Gramberg; Brian F Hutton; Kjell Erlandsson; Tali Sharir; Nathaniel Roth; Wendy A Waddington; Daniel S Berman; Peter J Ell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-04-11       Impact factor: 9.236

3.  Dual isotope and multidetector camera: The best choices for a specific end-point.

Authors:  Roberta Assante; Wanda Acampa
Journal:  J Nucl Cardiol       Date:  2016-05-19       Impact factor: 5.952

4.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential.

Authors:  Moshe Bocher; Ira M Blevis; Leonid Tsukerman; Yigal Shrem; Gil Kovalski; Lana Volokh
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-29       Impact factor: 9.236

5.  Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride.

Authors:  Celine Meyer; Pierre Weinmann
Journal:  J Nucl Cardiol       Date:  2016-04-20       Impact factor: 5.952

6.  Impact of photon energy recovery on the assessment of left ventricular volume using myocardial perfusion SPECT.

Authors:  Alain Manrique; Anne Hitzel; Pierre Véra
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

7.  Intra-patient reproducibility of myocardial SPECT imaging with 201Tl.

Authors:  Barbra E Backus; Frederik A Verburg; R Leo Romijn; Mark W Konijnenberg; Freek J Beekman; J Fred Verzijlbergen
Journal:  J Nucl Cardiol       Date:  2009-01-20       Impact factor: 5.952

8.  Optimisation of simultaneous tl-201/tc-99m dual isotope reconstruction with monte-carlo-based scatter correction.

Authors:  Tuija Kangasmaa; Jyrki Kuikka; Antti Sohlberg
Journal:  Int J Mol Imaging       Date:  2012-11-19

Review 9.  The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI.

Authors:  Monique R Bernsen; Pieter E B Vaissier; Roel Van Holen; Jan Booij; Freek J Beekman; Marion de Jong
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05       Impact factor: 9.236

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.