Literature DB >> 1914107

Dissolution of peripheral arterial thrombi by ultrasound.

M Ariani1, M C Fishbein, J S Chae, H Sadeghi, A D Michael, S B Dubin, R J Siegel.   

Abstract

BACKGROUND: We have previously shown that continuous-wave ultrasound can rapidly dissolve human thrombi in vitro, with 99% of all residual particles measuring less than 10 microns in diameter. To assess the effects of pulsed-wave ultrasound energy on whole blood clots, 1) in vitro studies were preformed to assess precisely the rates of clot disruption and to quantify particulate size, and 2) in vivo studies were performed to assess the efficacy and safety of catheter-delivered ultrasound for intra-arterial thrombus dissolution. METHODS AND
RESULTS: In vitro, we studied 50 samples of human whole blood clots and using an 89-cm-long wire probe, applied pulse-wave energies from 8 to 23 W. The corresponding peak-to-peak tip displacement range was 63.5 - 102 microns. We studied arterial thrombosis in vivo in 21 canine superficial femoral arteries. To produce an acute thrombosis, 200 units of thrombin followed by 2 ml of 72-hour-old autologous clot were injected into a 5-7-cm segment of femoral artery and left to coagulate for 2 hours. Ultrasound energy was intermittently applied at a frequency of 20 kHz with a prototype ultrasound wire ensheathed in a catheter and directed to clots by fluoroscopy. In nine cases, angioscopic guidance was used to put the probe into direct contact with the intra-arterial thromboses. In vitro clot dissolution times were inversely related to the ultrasound power output (r = 0.95). All in vivo canine thromboses were disrupted in 4 minutes or less. All successful recanalizations were confirmed by angiography and in nine cases by angioscopy as well. Angioscopy demonstrated that probe activation caused rapid clot disruption. Histological studies of the vessels showed no evidence of thermal or cavitation injury, occlusive distal embolization, or perforation.
CONCLUSIONS: Our findings in this experimental canine model suggest that ultrasound clot dissolution has the potential to be an effective and safe alternative to current treatment modalities for peripheral arterial thrombosis.

Entities:  

Mesh:

Year:  1991        PMID: 1914107     DOI: 10.1161/01.cir.84.4.1680

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  13 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Enhancement of fibrinolysis in vitro by ultrasound.

Authors:  C W Francis; P T Onundarson; E L Carstensen; A Blinc; R S Meltzer; K Schwarz; V J Marder
Journal:  J Clin Invest       Date:  1992-11       Impact factor: 14.808

6.  Ultrasound-enhanced tissue plasminogen activator thrombolysis in an in vitro porcine clot model.

Authors:  Christy K Holland; Sampada S Vaidya; Saurabh Datta; Constantin-C Coussios; George J Shaw
Journal:  Thromb Res       Date:  2007-09-14       Impact factor: 3.944

7.  Effectiveness of mechanical endovascular thrombectomy in a model system of cerebrovascular occlusion.

Authors:  J Y Chueh; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

8.  Effect of External Ultrasound Frequency on Thrombus Disruption In Vitro.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1996       Impact factor: 2.300

9.  Evaluation of ultrasound-assisted thrombolysis using custom liposomes in a model of retinal vein occlusion.

Authors:  Walid F Abdallah; Hitenkumar Patel; Edward G Grant; Bruno Diniz; Gerald J Chader; Mark S Humayun
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-10-05       Impact factor: 4.799

Review 10.  Perspectives on the role of ultrasonic devices in thrombolysis.

Authors:  Shaul Atar; Uri Rosenschein
Journal:  J Thromb Thrombolysis       Date:  2004-04       Impact factor: 2.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.