Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study.

J C Polf1, S Peterson, G Ciangaru, M Gillin, S Beddar.   

Abstract

In this paper, we present the results of a preliminary study of secondary 'prompt' gamma-ray emission produced by proton-nuclear interactions within tissue during proton radiotherapy. Monte Carlo simulations were performed for mono-energetic proton beams, ranging from 2.5 MeV to 250 MeV, irradiating elemental and tissue targets. Calculations of the emission spectra from different biological tissues and their elemental components were made. Also, prompt gamma rays emitted during delivery of a clinical proton spread-out Bragg peak (SOBP) in a homogeneous water phantom and a water phantom containing heterogeneous tissue inserts were calculated to study the correlation between prompt gamma-ray production and proton dose delivery. The results show that the prompt gamma-ray spectra differ significantly for each type of tissue studied. The relative intensity of the characteristic gamma rays emitted from a given tissue was shown to be proportional to the concentration of each element in that tissue. A strong correlation was found between the delivered SOBP dose distribution and the characteristic prompt gamma-ray production. Based on these results, we discuss the potential use of prompt gamma-ray emission as a method to verify the accuracy and efficacy of doses delivered with proton radiotherapy.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19131673     DOI: 10.1088/0031-9155/54/3/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

Authors:  Ben Clasie; Andrew Wroe; Hanne Kooy; Nicolas Depauw; Jay Flanz; Harald Paganetti; Anatoly Rosenfeld
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

2.  Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy.

Authors:  S W Peterson; D Robertson; J Polf
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

Review 3.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

Review 4.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

5.  The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras.

Authors:  Dennis Mackin; Jerimy Polf; Steve Peterson; Sam Beddar
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy.

Authors:  Daniel Robertson; Jerimy C Polf; Steve W Peterson; Michael T Gillin; Sam Beddar
Journal:  Phys Med Biol       Date:  2011-04-20       Impact factor: 3.609

7.  Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

Authors:  Jerimy C Polf; Rajesh Panthi; Dennis S Mackin; Matt McCleskey; Antti Saastamoinen; Brian T Roeder; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-08-06       Impact factor: 3.609

8.  3D prompt gamma imaging for proton beam range verification.

Authors:  E Draeger; D Mackin; S Peterson; H Chen; S Avery; S Beddar; J C Polf
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

9.  Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient.

Authors:  Jerimy C Polf; Dennis Mackin; Eunsin Lee; Stephen Avery; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

10.  Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy.

Authors:  Dennis Mackin; Steve Peterson; Sam Beddar; Jerimy Polf
Journal:  Phys Med Biol       Date:  2012-05-16       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.