An evaluation of knot integrity when tied robotically and conventionally.

Tyler Muffly1, T Chad McCormick, Julianne Dean, Aaron Bonham, Richard F C Hill.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the knot integrity of 3 commonly used sutures in sacrocolpopexy that were tied conventionally (by hand) and robotically. STUDY
DESIGN: Knots were tied with polyglactin 910, polypropylene, and polyester, with 5-6 knots tied, depending on the suture used. We compared the knots that were subjected to tensile force until the suture broke or untied.
RESULTS: The mean force that was required for the suture to untie was 47.7 +/- 18.8 (SD) Newtons and was seen only among the robotically tied polyglactin 910 knots. Robotically tied polyglactin 910 knots were significantly weaker than all other robotic and conventional knots that were tested (P < .05). The tying modality and material interaction was significant (P < .001), which suggests that the effect of suture material varied, depending on the tying modality.
CONCLUSION: Knot failure rates for conventional or robotically tied suture varied based on the suture material that was used.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19111718     DOI: 10.1016/j.ajog.2008.08.058

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  10 in total

Review 1.  Robot-assisted surgery:--impact on gynaecological and pelvic floor reconstructive surgery.

Authors:  O E O'Sullivan; B A O'Reilly
Journal:  Int Urogynecol J       Date:  2012-05-26       Impact factor: 2.894

2.  Two cases of post-coital vaginal cuff dehiscence with small bowel evisceration after robotic-assisted laparoscopic hysterectomy.

Authors:  My-Linh T Nguyen; Monica Kapoor; Tana S Pradhan; Tarah L Pua; Sean S Tedjarati
Journal:  Int J Surg Case Rep       Date:  2013-04-10

3.  Beyond the square knot: a novel knotting technique for surgical use.

Authors:  Chunfeng Zhao; Chung-Chen Hsu; Tamami Moriya; Andrew R Thoreson; Steven S Cha; Steven L Moran; Kai-Nan An; Peter C Amadio
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

4.  Robotic-assisted laparoscopic mesh sacrocolpopexy.

Authors:  Jason P Gilleran; Matthew Johnson; Andrew Hundley
Journal:  Ther Adv Urol       Date:  2010-10

5.  Knot integrity using different suture types and different knot-tying techniques for reconstructive pelvic floor procedures.

Authors:  Omar F Dueñas-Garcia; Gina M Sullivan; Katherine Leung; Kristen L Billiar; Michael K Flynn
Journal:  Int Urogynecol J       Date:  2017-06-20       Impact factor: 2.894

6.  Surgical knot tightening: how much pull is necessary?

Authors:  Stefan Neuhofer; Karl Wieser; Georg Lajtai; Daniel Müller; Christian Gerber; Dominik C Meyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-14       Impact factor: 4.342

7.  Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice.

Authors:  Xytilis Avoine; Bertrand Lussier; Vladimir Brailovski; Karine Inaekyan; Guy Beauchamp
Journal:  Can J Vet Res       Date:  2016-04       Impact factor: 1.310

8.  Long-term outcomes of robotic mesh sacrocolpopexy.

Authors:  Karen Jong; Ted Klein; Philippe E Zimmern
Journal:  J Robot Surg       Date:  2017-10-04

9.  Vaginal cuff dehiscence with bowel evisceration after robotic hysterectomy.

Authors:  Ali Akdemir; Enes Taylan; Ahmet Mete Ergenoğlu; Ahmet Özgür Yeniel; Fatih Şendağ; Mehmet Kemal Öztekin
Journal:  Turk J Obstet Gynecol       Date:  2014-12-15

10.  Vaginal cuff dehiscence in robotic-assisted total hysterectomy.

Authors:  Shabnam Kashani; Taryn Gallo; Anita Sargent; Karim Elsahwi; Dan-Arin Silasi; Masoud Azodi
Journal:  JSLS       Date:  2012 Oct-Dec       Impact factor: 2.172

  10 in total