Literature DB >> 10776940

Radiographic and digital imaging in periodontal practice.

E Hausmann1.   

Abstract

This review defines terms such as accuracy, validity, and reliability, which are used to describe the quality of methods for taking x-rays and for analyzing digital images. Values for these parameters are described for techniques of taking standardized x-rays such as ear-rod fixation and fixation by use of teeth with a dental impression. In addition, values are given for linear measurements on digitized images and for quantitative image subtraction. Differences are addressed between quantitative subtraction with a reference ramp and relative subtraction using the computer-assisted densitometric image analysis (CADIA) system. The relationship between radiographic bone height and clinical attachment level is also discussed. Finally, present and future use in the periodontal office of linear radiographic measurements on digital images and digital subtraction is discussed.

Entities:  

Mesh:

Year:  2000        PMID: 10776940     DOI: 10.1902/jop.2000.71.3.497

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  17 in total

1.  Repeatability and accuracy of a paralleling technique for radiographic evaluation of distal bone healing after impacted third molar surgery.

Authors:  A Inocêncio Faria; M Gallas Torreira; M López Ratón
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

3.  Radiographic outcomes following treatment of intrabony defect with guided tissue regeneration in aggressive periodontitis.

Authors:  Thanasak Rakmanee; Gareth S Griffiths; Gita Auplish; Ulpee Darbar; Aviva Petrie; Irwin Olsen; Nikolaos Donos
Journal:  Clin Oral Investig       Date:  2015-10-10       Impact factor: 3.573

4.  Three-dimensional micro-computed tomographic imaging of alveolar bone in experimental bone loss or repair.

Authors:  Chan Ho Park; Zachary R Abramson; Mario Taba; Qiming Jin; Jia Chang; Jaclynn M Kreider; Steven A Goldstein; William V Giannobile
Journal:  J Periodontol       Date:  2007-02       Impact factor: 6.993

5.  A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery.

Authors:  Faria-Inocencio Ana; Gallas-Torreira Mercedes
Journal:  Imaging Sci Dent       Date:  2011-09-15

6.  Pose determination of a cylindrical (dental) implant in three-dimensions from a single two-dimensional radiograph.

Authors:  R K W Schulze
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

7.  Effectiveness of a personalized device in the evaluation of mandibular second molar periodontal healing after surgical extraction of adjacent third molar.

Authors:  Roberto Pippi
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

8.  Influence of image filters on the reproducibility measurements of alveolar bone loss.

Authors:  Wivian Eiras Garcia Wong Alves; Evelise Ono; Jefferson Luis Oshiro Tanaka; Titular Edmundo Medici Filho; Luiz César de Moraes; Mari Eli Leonelli de Moraes; Julio Cezar de Melo Castilho
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

Review 9.  Choice of diagnostic and therapeutic imaging in periodontics and implantology.

Authors:  Swarna Chakrapani; K Sirisha; Anumadi Srilalitha; Moogala Srinivas
Journal:  J Indian Soc Periodontol       Date:  2013-11

10.  Correlation of the interdental and the interradicular bone loss: A radiovisuographic analysis.

Authors:  Vishakha Grover; Ranjan Malhotra; Anoop Kapoor; Chahat Singh Mankotia; Rupika Bither
Journal:  J Indian Soc Periodontol       Date:  2014-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.