| Literature DB >> 19089111 |
Flávio Henrique Baggio Aguiar1, Thalita Regina Vieira E Oliveira, Débora Alves Nunes Leite Lima, Luis Alexandre Maffei Sartini Paulillo, José Roberto Lovadino.
Abstract
The aim of this in vitro study was to evaluate the susceptibility of a hybrid composite resin (Filtek Z250 - 3M ESPE) to staining, when light cured in four different modes and immersed in two different media. Composite resin specimens were randomly prepared and polymerized according to the experimental groups (conventional -50 mW/cm(2) / 30 seconds; soft start -300 mW/cm(2) / 10 seconds + 550 mW/cm(2) / 20 seconds; high intensity -1060 mW/cm(2)--10 seconds; pulse delay -550 mW/cm(2)--1 seconds + 60 seconds of waiting time + 550 mW/cm(2)--20 seconds) and immersed in one of two media (distilled water or absolute ethanol) for 24 h. Next, the specimens were immersed in a 2% methylene blue solution for 12 hours. Afterwards, the specimens were washed and prepared for the spectrophotometric analysis. For statistical analysis, two-way ANOVA (4X2) and Tukey's test were performed on the data at 0.05 confidence level. Soft start showed the least staining, and was statistically different from the high intensity and pulse delay light curing modes (p<0.05). Conventional light curing unit did not show statistically significant differences from any other groups (p>0.05). There were no significant differences between the two immersion media (p>0.05). The soft start polymerization mode showed lower susceptibility of the composite resin to staining than high intensity and pulse delay, irrespective of the immersion medium.Entities:
Year: 2007 PMID: 19089111 PMCID: PMC4327239 DOI: 10.1590/s1678-77572007000200006
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Experimental groups (light curing modes)
| Experimental Groups | Light Curing Intensity | Light Curing Unit |
|---|---|---|
| Conventional | 550 mW/cm2 / 30 s | XL 3000 – 3M Espe |
| Soft Start | 300mW/cm2 / 10 s + 550 mW/cm2 / 20 s | XL 3000 – 3M Espe |
| High Intensity | 1060mW/cm2 – 10 s | Optilux 501C - Demetron |
| Pulse Delay | 550mW/cm2 – 1 s + 60 s of waiting time + 550mW/cm2 – 20 s | XL 3000 – 3M Espe |
Results of staining means for the experimental groups (light curing modes) (μg/mL). Means with the same lowercase letter were not statistically different (p<0.05) for comparisons between the same medium. Means with the same uppercase letter were not statistically significant different (p<0.05) for comparisons between the same polymerization mode
| Experimental Groups | Water Media | Ethanol media |
|---|---|---|
| Conventional | 0,356 A ab | 0,372 A ab |
| Soft Start | 0,290 A a | 0,350 A a |
| High Intensity | 0,424 A b | 0,408 A b |
| Pulse Delay | 0,394 A b | 0,422 A b |
Results of 2-way ANOVA
| Source of variation | DF | SQ | MQ | F |
|---|---|---|---|---|
| Light curing modes (LCM) | 3 | .0006 | .0002 | 3.9330 |
| Immersion media (IM) | 1 | .0000 | .0000 | .8911 NS |
| LCM X IM | 3 | .0001 | .0000 | .4472 NS |
| Treatments | 7 | .0007 | .0001 | |
| Error | 32 | .0015 | .0015 |
DF – degree of freedom; SQ – Sum of squares; MQ – Mean square;
- statistically significant difference; NS - no statistically significant difference.