Literature DB >> 32562075

Sealer penetration: effect of separated file's cross-section, taper and motion characteristics.

Ayhan Eymirli1, Emel Uzunoğlu Özyürek2, Ahmet Serper1.   

Abstract

OBJECTIVES: The separated root canal instruments may affect the quality of root canal filling, hence the success of endodontic treatment. The aim of this study was to evaluate the effects of separated file fragments of nickel-titanium rotary systems with different cross-section, taper and motion characteristics on the apical sealer penetration in oval-shaped root canals via confocal laser scanning microscope (CLSM).
MATERIALS AND METHODS: Distal roots of 60 mandibular molars with oval-shaped root canals were randomly divided into 4 groups as follows: group 1, FlexMaster Nickel Titanium Rotary File System (NTRFS) (separated instrument: 30/.06); group 2, ProTaper Next NTRFS (X3); group 3, ProTaper Universal NTRFS (F3); group 4, Revo-S NTRFS (AS30/.06). Root canals were filled with gutta-percha and AH plus labelled with 0.1% rhodamine B using a warm vertical compaction technique. Each specimen was horizontally sectioned at 1st, 3rd and 5th mm from apical foramen. Amount of maximum and average penetration depths, penetration percentage and sealer penetrated area were measured and analysed with one-way repeated measures of ANOVA and the Bonferroni post hoc tests. p < 0.05 was considered significant.
RESULTS: The penetration depth, percentage and penetrated area of the sealer increased from apical to coronal in all systems. The maximum and average penetration depths and penetration areas were higher in FlexMaster and Revo-S groups at the 3rd mm (p < 0.05). At the 5th mm, the Revo-S group had a higher penetration percentage, when compared with ProTaper Next and ProTaper Universal groups (p < 0.05).
CONCLUSIONS: In the 1st mm, separated fragments of any system did not allow the penetration of the sealer, while it was observed that the files with constant taper showed more positive results in terms of sealer penetration at apical 3rd and 5th mm. CLINICAL RELEVANCE: In the presence of a separated file, the taper of the file might significantly affect the amount of penetrated sealer into the dentinal tubules as compared with the cross-section and motion characteristics of the file.

Entities:  

Keywords:  AH plus; Confocal laser scanning microscopy; Nickel-titanium rotary systems; Separated file; Tubule penetration

Mesh:

Substances:

Year:  2020        PMID: 32562075     DOI: 10.1007/s00784-020-03404-3

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  41 in total

1.  Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases.

Authors:  Jeff R Ward; Peter Parashos; Harold H Messer
Journal:  J Endod       Date:  2003-11       Impact factor: 4.171

2.  Success rates for removing or bypassing fractured instruments: a prospective clinical study.

Authors:  Giselle Nevares; Rodrigo Sanches Cunha; Mário Luis Zuolo; Carlos Eduardo da Silveira Bueno
Journal:  J Endod       Date:  2012-01-09       Impact factor: 4.171

3.  The impact of instrument fracture on outcome of endodontic treatment.

Authors:  Peter Spili; Peter Parashos; Harold H Messer
Journal:  J Endod       Date:  2005-12       Impact factor: 4.171

Review 4.  Rotary NiTi instrument fracture and its consequences.

Authors:  Peter Parashos; Harold H Messer
Journal:  J Endod       Date:  2006-11       Impact factor: 4.171

5.  SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use.

Authors:  Satish B Alapati; William A Brantley; Timothy A Svec; John M Powers; John M Nusstein; Glenn S Daehn
Journal:  J Endod       Date:  2005-01       Impact factor: 4.171

6.  Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy.

Authors:  Jintao Wu; Gang Lei; Ming Yan; Yan Yu; Jinhua Yu; Guangdong Zhang
Journal:  J Endod       Date:  2011-04-02       Impact factor: 4.171

7.  A survey of adoption of endodontic nickel-titanium rotary instrumentation part 2: community and hospital dental practitioners in Wales.

Authors:  M B Thomas; M Locke; P M H Dummer
Journal:  Br Dent J       Date:  2013-02       Impact factor: 1.626

Review 8.  Management of intracanal separated instruments.

Authors:  Ahmad A Madarati; Mark J Hunter; Paul M H Dummer
Journal:  J Endod       Date:  2013-03-15       Impact factor: 4.171

9.  Complications associated with fractured file removal using an ultrasonic technique.

Authors:  Nigel J Souter; Harold H Messer
Journal:  J Endod       Date:  2005-06       Impact factor: 4.171

Review 10.  Clinical decision-making after endodontic instrument fracture.

Authors:  M B McGuigan; C Louca; H F Duncan
Journal:  Br Dent J       Date:  2013-04       Impact factor: 1.626

View more
  1 in total

1.  Microleakage of five separated nickel-titanium rotary file systems in the apical portion of the root canal.

Authors:  Seyed Mohsen Hasheminia; Alireza Farhad; Hamidreza Davoudi; Dorna Sarfaraz
Journal:  Dent Res J (Isfahan)       Date:  2022-06-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.