Surgical removal of fractured endodontic instrument in the periapex of mandibular first molar.

Adil Gandevivala1, Bandish Parekh2, Gaurav Poplai2, Aliya Sayed3.   

Abstract

The purpose of this article is to present the surgical removal of a broken endodontic file from the periapical region of the distal root of a mandibular first molar. The methods of diagnosis and measurement of the distance of the instrument to the adjacent vital structures in the periapical region was done with simple means and in an economical manner.

Entities:  

Keywords:  Fractured endodontic instrument; mandibular first molar; periapical surgery

Year:  2014        PMID: 25214740      PMCID: PMC4148581     

Source DB:  PubMed          Journal:  J Int Oral Health        ISSN: 0976-1799


Introduction

Fracture of root canal instruments is one of the most troublesome incidents in endodontic therapy. Several studies focused on factors influencing defects of endodontic instruments after clinical use, and some recommendations were given to minimize the risk of instrument breakage.1-3 It is reported that the prevalence of broken instruments ranges from 0.5% to 5%.4-7 If the broken file impedes adequate cleaning of the canal beyond the obstruction, prognosis might be adversely affected.8 Many a times, this lead to failure of root canal therapy and burdened the patients with anxiety.9,10 Strindberg found a statistically significant 19% higher failure frequency for cases in which there was instrument breakage compared with cases without breakage.11 Therefore, the best option in the management of root canal instrument fracture is removal.12 Several techniques and devices have been used for the removal of broken instruments.13-15 Difficult cases are occasionally encountered in which the separated file cannot be retrieved from the canal.8 Intentionally leaving a fragment in the root canal might be considered when non-surgical removal has been attempted without success.16 In addition, vigorous reduction of the dentinal walls of the root canal space might cause perforation of the canal wall. This can adversely affect the prognosis of teeth.17 Endodontic instruments rarely separate beyond the apical foramen. The fractured segment, always accompanied with bacteria and dentine debris, is a foreign object and might cause inflammation.18,19 Moreover, patients often regard the fractured segment as “a broken needle” and suffer psychologically. Therefore, an attempt to remove the segment from such cases with a surgical approach is often necessary. Before surgery, the precise position and size of the fractured instrument should be understood as well as its relation to the root apex and surrounding anatomic structures.20 The aim of the article is to present a case that used RVG to locate and successfully remove a fractured endodontic instrument partially beyond the apical foramen using a surgical approach.

Case Report

A 32-year-old Indian female patient came to the Department of Conservative Dentistry and Endodontics at our institute with a complaint of pain in the lower left posterior region. On clinical and radio graphical examination, it was diagnosed as a case of irreversible pulpitis due to a deep carious lesion involving the pulp and it was indicated for root canal treatment. Medical history was unremarkable. After access opening, cleaning and shaping was initiated. Rotary protapers (Dentsply Maillefer, Ballaigues, Switzerland) were used with a 64:1 reduction gear Rotary endodontic hand piece (NSK, Nakanishi, Japan). In the process of cleaning and shaping, a 5 mm segment of F2 rotary protaper got fractured in the apical 1/3rd of the distal canal (Figure 1). A decision to remove the instrument non-surgically was undertaken with the consent of the patient.
Figure 1

Broken instrument in the apical third.

Broken instrument in the apical third. In an attempt to remove the file using microsonics, the file got accidentally pushed into the canal such that 2/3rd of the file was beyond the periapex and 1/3rd inside the canal (Figure 2).
Figure 2

Instrument got pushed beyond to the periapex measurement with radiographic marker (10 mm).

Instrument got pushed beyond to the periapex measurement with radiographic marker (10 mm). The tooth was temporized and the patient was informed regarding the mishap and kept under observation for a week. During the recall, the patient gave a positive history for pain on mastication and a decision was made to surgically remove the fragment.

Pre-operative preparations

A 19 gauge wire of a known length (10 mm) was used as a radiographic marker and was taped to the sensor, while taking the RVG. The radiographic marker was then measured on the RVG to calculate any elongation or shortening of the image (Figure 2). The RVG was taken to measure: (1) The exact size of the fractured instrument, (2) the distance from the reference point (Distobuccal cusp) to the apex of the tooth, and (3) the distance from the reference point to the upper border inferior alveolar canal. The actual size of the marker was compared with the size of the marker on the RVG and the above mentioned measurements were made. In our case, the pre-determined length of the radiographic marker coincided with its length on the RVG. Therefore all measurements were directly carried out using the RVG software.

Procedure

The procedure was performed under local anesthesia 2% lignocaine with 1:2,00,000 adrenaline. A crevicular incision was given from the mesial aspect of the mandibular left first pre-molar till the distal aspect of the mandibular left second molar and a distal releasing incision extending into the vestibule was taken to raise a triangular flap. Subperiosteal reflection was done. A 5 mm bony window was prepared through the buccal cortex corresponding to the distal root apex of the molar at the previously calculated length (Figure 3). The instrument was carefully visualized and then removed with a mosquito forceps. A post-operative radiograph was taken to confirm complete removal of the fractured segment (Figure 4). Next, the distal canal was obturated using 6% gutta-percha and 4% accessory cones and AH plus Sealer (Dentsply, Maillefer). The gutta-percha was burnished at the apical end of the distal canal with a hot burnisher. The wound was then curetted, and irrigation was done with normal saline. Demineralised freeze dried bone allograft was used to graft the surgical site and closure was done with 3-0 silk. Patient was prescribed amoxicillin 500 mg/8 h for 7 days, ibuprofen 600 mg/8 h for 3 days, and 0.12% chlorhexidine gluconate mouthwash thrice a day for 7 days. After 7 days, the patient was recalled for suture removal. Routine endodontic therapy was then carried out later under rubber dam application, and the mesial canals were obturated and a post-endodontic restoration was done. At the 6 month recall examination, the mandibular left first molar was asymptomatic with progressive regeneration of the periapical bone (Figure 5).
Figure 3

Bony window created.

Figure 4

Instrument removal done.

Figure 5

Six months postoperative radiograph.

Bony window created. Instrument removal done. Six months postoperative radiograph.

Discussion

Endodontic procedural errors, such as under-filling, over-filling, fractured instruments, and root perforations and ledges, increase the risk of post-treatment disease largely as a result of the inability to eliminate intra-radicular microorganisms from the infected root canal.19 When an instrument fractures during root canal preparation, there are three basic approaches to deal with the problem: (i) Remove it; (ii) bypass and seal it within the root canal; or (iii) block the root canal with it.21-23 A thorough history, clinical examination, and good quality periapical radiographs are essential for pre-operative diagnosis of teeth scheduled to undergo apical surgery.24 Periapical surgery in mandibular molars presents certain technical difficulties such as the close proximity of the apices to the mandibular canal, difficult access to the roots due to their posterior location and their lingual inclination and type and thickness of the buccal plate.25,26 The close proximity of the pathologic process to the mandibular canal can be a difficult surgical problem in terms of protecting this vital structure from damage. Wesson and Gale found a sensory disturbance of variable duration in the lower lip after 20%-21% of mandibular molar procedures.27 Periapical radiography is limited by the fact that information is rendered in only two dimensions. Interpretation is more difficult when the background pattern is complex.28 The use of computed tomography (CT) scans has enabled evaluation of the true extent of periapical lesions and their spatial relationship to important anatomical landmarks.29 The introduction of cone-beam CT represented an important new development in dentomaxillofacial radiology and precipitated a shift from 2 to 3 dimensional data acquisition, image reconstruction, and visualization.30

Conclusion

Precise location of the fractured segment was predicted and removed with the aid of modern gadgets and tooth was successfully treated without any complications.
  27 in total

1.  Periapical healing of mandibular molars after root-end sealing with dentine-bonded composite.

Authors:  J Rud; V Rud; E C Munksgaard
Journal:  Int Endod J       Date:  2001-06       Impact factor: 5.264

2.  Molar apicectomy with amalgam root-end filling: results of a prospective study in two district general hospitals.

Authors:  C M Wesson; T M Gale
Journal:  Br Dent J       Date:  2003-12-20       Impact factor: 1.626

3.  Modified usage of the Masserann kit for removing intracanal broken instruments.

Authors:  Takashi Okiji
Journal:  J Endod       Date:  2003-07       Impact factor: 4.171

4.  Factors affecting the long-term results of endodontic treatment.

Authors:  U Sjogren; B Hagglund; G Sundqvist; K Wing
Journal:  J Endod       Date:  1990-10       Impact factor: 4.171

Review 5.  Do procedural errors cause endodontic treatment failure?

Authors:  Louis M Lin; Paul A Rosenberg; Jarshen Lin
Journal:  J Am Dent Assoc       Date:  2005-02       Impact factor: 3.634

6.  Separation incidence of protaper rotary instruments: a large cohort clinical evaluation.

Authors:  Susan Wolcott; James Wolcott; David Ishley; Wade Kennedy; Scott Johnson; Scott Minnich; John Meyers
Journal:  J Endod       Date:  2006-09-28       Impact factor: 4.171

7.  A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study.

Authors:  Mian K Iqbal; Meetu R Kohli; Jessica S Kim
Journal:  J Endod       Date:  2006-09-25       Impact factor: 4.171

8.  Evaluating two techniques on removal of fractured rotary nickel-titanium endodontic instruments from root canals: an in vitro study.

Authors:  Khalid H Alomairy
Journal:  J Endod       Date:  2009-04       Impact factor: 4.171

9.  Ultrasonic removal of broken instruments in root canals.

Authors:  O Nagai; N Tani; Y Kayaba; S Kodama; T Osada
Journal:  Int Endod J       Date:  1986-11       Impact factor: 5.264

10.  Treatment outcome in endodontics: the Toronto study. Phases I and II: Orthograde retreatment.

Authors:  Mahsa Farzaneh; Sarah Abitbol; Shimon Friedman
Journal:  J Endod       Date:  2004-09       Impact factor: 4.171

View more
  5 in total

1.  Evaluation of the Factors and Treatment Options of Separated Endodontic Files Among Dentists and Undergraduate Students in Riyadh Area.

Authors:  Samah Samir Pedir; Abeer Hashem Mahran; Khaled Beshr; Kusai Baroudi
Journal:  J Clin Diagn Res       Date:  2016-03-01

2.  Surgical Management of a Separated Endodontic Instrument using Second Generation Platelet Concentrate and Hydroxyapatite.

Authors:  S L Satheesh; Shefali Jain; Atul Chandra Bhuyan; Lekshmy S Devi
Journal:  J Clin Diagn Res       Date:  2017-06-01

3.  Removal of a Broken Instrument from a Tooth with Apical Periodontitis Using a Novel Approach.

Authors:  Azar Heydari; Mona Rahmani; Mostafa Heydari
Journal:  Iran Endod J       Date:  2016-05-01

4.  Use of an intraoperative navigation system for retrieving a broken dental instrument in the mandible: a case report.

Authors:  Shintaro Sukegawa; Takahiro Kanno; Akane Shibata; Kenichi Matsumoto; Yuka Sukegawa-Takahashi; Kyosuke Sakaida; Yoshihiko Furuki
Journal:  J Med Case Rep       Date:  2017-01-15

5.  Nasal septal foreign body as a complication of dental root canal therapy: A case report.

Authors:  Xiao-Wan Du; Jun-Bo Zhang; Shui-Fang Xiao
Journal:  World J Clin Cases       Date:  2021-01-26       Impact factor: 1.337

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.