Literature DB >> 19050883

Five-year DEXA study of 88 hips with cemented femoral stem.

Georgios Digas1, Johan Kärrholm.   

Abstract

We performed repeated dual-energy X-ray absorptiometry (DEXA) measurements over five years in a homogeneous patient population to study the effect of a cemented stem on proximal femoral bone remodelling. Data from 88 patients (88 hips) implanted with total hip arthroplasty (THA) prostheses were extracted from three randomised studies. Femoral bone mineral density (BMD) was measured using a Lunar DPX-IQ densitometer for five years postoperatively. At one year the BMD changes had decreased between -2.0% [region of interest (ROI) 1] and -11.5% (ROI 7). During the follow-up period the BMD initially increased during the second year and thereafter decreased again in ROIs 5, 6 and 7. The loss of BMD at five years was more pronounced in region 7 (12.9%) and decreased with increasing age, total hip replacement (THR) on the right side and decreasing weight of the patient. We found that after the initial phase of early bone loss a period of recovery follows. Thereafter the BMD decreases again, which probably reflects the normal ageing of bone after uncomplicated cemented THA.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19050883      PMCID: PMC2899162          DOI: 10.1007/s00264-008-0699-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  27 in total

1.  Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty.

Authors:  B J Kiratli; J P Heiner; A A McBeath; M A Wilson
Journal:  J Orthop Res       Date:  1992-11       Impact factor: 3.494

Review 2.  Quantitative computer-assisted osteodensitometry in total hip arthroplasty.

Authors:  R P Pitto; L A Mueller; K Reilly; R Schmidt; J Munro
Journal:  Int Orthop       Date:  2006-10-17       Impact factor: 3.075

3.  Quantitative CT-assisted osteodensitometry of femoral adaptive bone remodelling after uncemented total hip arthroplasty.

Authors:  Rocco P Pitto; Aknaksha Bhargava; Salil Pandit; Cameron Walker; Jacob T Munro
Journal:  Int Orthop       Date:  2007-06-20       Impact factor: 3.075

4.  Quantifying bone loss from the proximal femur after total hip arthroplasty.

Authors:  C K McCarthy; G G Steinberg; M Agren; D Leahey; E Wyman; D T Baran
Journal:  J Bone Joint Surg Br       Date:  1991-09

Review 5.  Bone density at the proximal femur after total hip arthroplasty.

Authors:  H Kröger; P Venesmaa; J Jurvelin; H Miettinen; O Suomalainen; E Alhava
Journal:  Clin Orthop Relat Res       Date:  1998-07       Impact factor: 4.176

6.  Radiostereometry of hip prostheses. Review of methodology and clinical results.

Authors:  J Kärrholm; P Herberts; P Hultmark; H Malchau; B Nivbrant; J Thanner
Journal:  Clin Orthop Relat Res       Date:  1997-11       Impact factor: 4.176

7.  Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: precision of the method and effect of operation on bone mineral density.

Authors:  H Kröger; H Miettinen; I Arnala; E Koski; N Rushton; O Suomalainen
Journal:  J Bone Miner Res       Date:  1996-10       Impact factor: 6.741

8.  Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty.

Authors:  T Nishii; N Sugano; K Masuhara; T Shibuya; T Ochi; S Tamura
Journal:  Clin Orthop Relat Res       Date:  1997-06       Impact factor: 4.176

9.  Variation between femurs as measured by dual energy X-ray absorptiometry (DEXA).

Authors:  M L Hall; J Heavens; P J Ell
Journal:  Eur J Nucl Med       Date:  1991

10.  Continuous bone loss around a tapered uncemented femoral stem: a long-term evaluation with DEXA.

Authors:  Henrik S G Bodén; Olof G Sköldenberg; Mats O F Salemyr; Hans-Jerker Lundberg; Per Y Adolphson
Journal:  Acta Orthop       Date:  2006-12       Impact factor: 3.717

View more
  8 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Femoral bone density changes after total hip arthroplasty with uncemented taper-design stem: a five year follow-up study.

Authors:  Rocco P Pitto; Annabel Hayward; Cameron Walker; Vickie B Shim
Journal:  Int Orthop       Date:  2009-11-28       Impact factor: 3.075

3.  Peri-prosthetic bone remodeling and change in bone mineral density in the femur after cemented polished tapered stem implantation.

Authors:  Toshiki Iwase; Daigo Morita; Genta Takemoto; Hiroshi Fujita; Naoyuki Katayama; Hiromi Otsuka
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-03-08

4.  Periprosthetic bone mineral density with a cementless triple tapered stem is dependent on daily activity.

Authors:  Shinya Hayashi; Takayuki Nishiyama; Takaaki Fujishiro; Noriyuki Kanzaki; Shingo Hashimoto; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2011-11-30       Impact factor: 3.075

5.  Bone mineral density as a marker of hip implant longevity: a prospective assessment of a cementless stem with dual-energy X-ray absorptiometry at twenty years.

Authors:  Giuseppe Sessa; Luciano Costarella; Calogero Puma Pagliarello; Antonio Di Stefano; Andrea Sessa; Gianluca Testa; Vito Pavone
Journal:  Int Orthop       Date:  2018-10-03       Impact factor: 3.075

6.  Knee flexion influences periprosthetic BMD measurement in the tibia. Suggestions for a reproducible clinical scan protocol.

Authors:  Maiken Stilling; Kjeld Søballe; Kristian Larsen; Niels Trolle Andersen; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

7.  Less periprosthetic bone loss following the anterolateral approach to the hip compared with the direct lateral approach.

Authors:  Terje O Ugland; Glenn Haugeberg; Svein Svenningsen; Stein H Ugland; Øystein H Berg; Are Hugo Pripp; Lars Nordsletten
Journal:  Acta Orthop       Date:  2017-10-17       Impact factor: 3.717

8.  Stro-1-positive BMSCs predict postoperative periprosthetic bone mineral density outcomes in uncemented total hip arthroplasty patients.

Authors:  Yi Shen; Xiaomiao Li; Yurun Ding; Weiping Ren; Weili Wang
Journal:  Med Sci Monit       Date:  2014-03-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.