[Metal artefact on head and neck cone-beam CT images].

Miklós Kovacs1, Pál Fejérdy, Nagy Csaba Dobó.   

Abstract

There are only a few factors, where the properties of the CBCT is inferior compared to conventional CT. One of these properties is the low contrast resolution, which has an importance in the discrimination of different soft tissues. Another difference is the image quality degrading effect by metal objects. This latter factor has much higher importance in head and neck region CBCT application. The metal artifact is closely related to other types of artifacts, like beam-hardening and x-ray photon scattering artifacts. In some of the cases, metal artifacts can be avoided by the proper adjustment of the scanning parameters, but sometimes the problem overgrows the possibilities. The current pre- and post-processing algorithms used for the correction of different artifacts can improve the image quality, but these algorithms are not the ultimate solution to the problem. The introduction of iterative reconstruction algorithms into the CBCT market will effectively reduce the most CT artifacts, however, the spread of this algorithms are set back because of the insufficient computational power of today's PCs. Another advantage of the use of iterative algorithms is that the patient dose could be significantly reduced.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19039918

Source DB:  PubMed          Journal:  Fogorv Sz        ISSN: 0015-5314


  6 in total

1.  Regional 3D superimposition to assess temporomandibular joint condylar morphology.

Authors:  J Schilling; L C R Gomes; E Benavides; T Nguyen; B Paniagua; M Styner; V Boen; J R Gonçalves; L H S Cevidanes
Journal:  Dentomaxillofac Radiol       Date:  2013-10-29       Impact factor: 2.419

2.  Cone-beam CT to assess bony fusion following anterior cervical interbody fusion.

Authors:  Jan Erik Vandevenne; Dieter Peuskens; Leen Wijnen; Jan Wuyts
Journal:  Eur Spine J       Date:  2015-09-28       Impact factor: 3.134

3.  Spectral CT with monochromatic imaging and metal artifacts reduction software for artifacts reduction of ¹²⁵I radioactive seeds in liver brachytherapy.

Authors:  Qiuxia Yang; Sheng Peng; Jing Wu; Xiaohua Ban; Mingyan He; Chuanmiao Xie; Rong Zhang
Journal:  Jpn J Radiol       Date:  2015-10-11       Impact factor: 2.374

4.  Sinus Floor Elevation via an Osteotome Technique without Biomaterials.

Authors:  Rodrigo Andrés-García; José Vicente Ríos-Santos; Mariano Herrero-Climent; Pedro Bullón; Javier Fernández-Farhall; Alberto Gómez-Menchero; Ana Fernández-Palacín; Blanca Ríos-Carrasco
Journal:  Int J Environ Res Public Health       Date:  2021-01-27       Impact factor: 3.390

5.  Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography.

Authors:  Fusong Yuan; Litong Chen; Xiaofei Wang; Yong Wang; Peijun Lyu; Yuchun Sun
Journal:  Sci Rep       Date:  2016-05-17       Impact factor: 4.379

6.  Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT.

Authors:  J K Dusseldorp; H C Stamatakis; Y Ren
Journal:  Clin Oral Investig       Date:  2016-05-21       Impact factor: 3.573

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.