Literature DB >> 26416520

Cone-beam CT to assess bony fusion following anterior cervical interbody fusion.

Jan Erik Vandevenne1,2, Dieter Peuskens3, Leen Wijnen4, Jan Wuyts3.   

Abstract

PURPOSE: Assessment of bony fusion following anterior cervical interbody fusion (ACIF) is usually done by plain film or CT. We present the first clinical application of Cone-Beam CT (CBCT) to evaluate bony fusion after ACIF.
METHODS: A 56-year-old man with disc herniation at C6-C7 underwent ACIF surgery using a compressed nanocrystalline hydroxyapatite interbody device (nanOss-C, Pioneer Surgical Marquette, MI, USA) and a nanocrystalline hydroxyapatite bone graft filler (nanOss Bioactive, Pioneer Surgical Marquette, MI, USA). Imaging follow-up was performed by CBCT (NewTom 5G, QR Srl, Verona, Italy) at 1 day, 6 weeks, 3 and 9 months post-operatively. Two independent assessors quantitatively measured the greyscale changes of the bone graft filler and qualitatively evaluated the bony fusion process.
RESULTS: Quantitative analysis of the images showed a steadily increasing matrix density of the bone graft filler over the 9 months follow-up, suggesting increasing calcification. Qualitative evaluation demonstrated different stages of the bone fusion process within the disc space around the cage, at the interface between cage and endplates, and at the interface between bone graft filler and the endplates.
CONCLUSIONS: CBCT provides high-resolution cross-sectional imaging of the cervical spine after ACIF. For the first time, in vivo evaluation of the bone graft filler within the centre of the circumferentially radiodense cage and detailed cross-sectional evaluation of bone fusion was achieved. Confirmation of these promising outlooks of CBCT in a large cohort of ACIF patients is needed with regard to routine clinical application and evaluation of different interbody devices.

Entities:  

Keywords:  ACIF procedure; Cone-beam CT; Fusion; Greyscale

Mesh:

Substances:

Year:  2015        PMID: 26416520     DOI: 10.1007/s00586-015-4248-8

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  14 in total

Review 1.  Follow-up radiographs to detect callus formation after fractures.

Authors:  D W McKinley; M L Chambliss
Journal:  Arch Fam Med       Date:  2000-04

Review 2.  Dental cone beam CT and its justified use in oral health care.

Authors:  R Jacobs
Journal:  JBR-BTR       Date:  2011 Sep-Oct

3.  Effective dose range for dental cone beam computed tomography scanners.

Authors:  Ruben Pauwels; Jilke Beinsberger; Bruno Collaert; Chrysoula Theodorakou; Jessica Rogers; Anne Walker; Lesley Cockmartin; Hilde Bosmans; Reinhilde Jacobs; Ria Bogaerts; Keith Horner
Journal:  Eur J Radiol       Date:  2010-12-31       Impact factor: 3.528

Review 4.  [Metal artefact on head and neck cone-beam CT images].

Authors:  Miklós Kovacs; Pál Fejérdy; Nagy Csaba Dobó
Journal:  Fogorv Sz       Date:  2008-10

5.  Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications.

Authors:  M Loubele; R Bogaerts; E Van Dijck; R Pauwels; S Vanheusden; P Suetens; G Marchal; G Sanderink; R Jacobs
Journal:  Eur J Radiol       Date:  2008-07-18       Impact factor: 3.528

6.  Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.

Authors:  John B Ludlow; Marija Ivanovic
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-05-27

7.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

8.  In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography.

Authors:  Goran I Benic; Manuel Sancho-Puchades; Ronald E Jung; Hans Deyhle; Christoph H F Hämmerle
Journal:  Clin Oral Implants Res       Date:  2012-10-29       Impact factor: 5.977

9.  Micro-computed tomography assessment of fracture healing: relationships among callus structure, composition, and mechanical function.

Authors:  Elise F Morgan; Zachary D Mason; Karen B Chien; Anthony J Pfeiffer; George L Barnes; Thomas A Einhorn; Louis C Gerstenfeld
Journal:  Bone       Date:  2008-10-25       Impact factor: 4.398

10.  Relationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT.

Authors:  Tahmineh Razi; Mahdi Niknami; Fakhri Alavi Ghazani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-06-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.