Literature DB >> 19034134

Corneal patch graft repair of exposed glaucoma drainage implants.

Mandeep Singh1, Paul T K Chew, Donald Tan.   

Abstract

PURPOSE: The purpose of this study was to describe a novel method of repair for exposed glaucoma drainage implants (GDIs) using corneal patch grafts.
METHODS: This is a retrospective review of patients who underwent corneal patch graft repair of exposed GDIs at 2 tertiary ophthalmic centers in Singapore from November 1, 2000, to January 31, 2006. Surgical outcome was assessed in terms of tectonic integrity of the graft over the period of follow-up. Endpoints assessed were epithelialization of graft and absence of reexposure of GDI, scleral thinning, and infection.
RESULTS: Eight eyes of 7 patients were analyzed, with a mean follow-up of 36.3 +/- 28.4 months (range 11-83 months). The mean age of patients was 57.0 +/- 20.8 years. The mean interval between GDI implantation and first occurrence of tube exposure was 22.1 +/- 26.3 months (range 1-78 months). Six (75.0%) eyes had undergone 1 or more procedures for surgical repair of tube exposure before corneal patch graft surgery, including direct closure of conjunctival defect overlying the GDI tube or repair using conjunctival autograft or donor pericardium or sclera. After corneal patch graft surgery, 7 (87.5%) eyes had stable conjunctival coverage with no epithelial breakdown over the corneal patch graft and with no reexposure of the GDI, scleral thinning, or ocular infection during follow-up.
CONCLUSIONS: Corneal patch graft repair of exposed GDIs is an effective method to provide stable GDI coverage after exposure.

Entities:  

Mesh:

Year:  2008        PMID: 19034134     DOI: 10.1097/ICO.0b013e3181814d15

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  13 in total

1.  Measurement of Gamma-Irradiated Corneal Patch Graft Thickness After Aqueous Drainage Device Surgery.

Authors:  Regina A de Luna; Ameera Moledina; Jiangxia Wang; Henry D Jampel
Journal:  JAMA Ophthalmol       Date:  2017-09-01       Impact factor: 7.389

2.  Clinical outcomes of gamma-irradiated sterile cornea in aqueous drainage device surgery: a multicenter retrospective study.

Authors:  Q Pan; H D Jampel; P Ramulu; G F Schwartz; F Cotter; D Cute; Y J Daoud; P Murakami; W J Stark
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

3.  The use of glycerol-preserved corneas in the developing world.

Authors:  Michael R Feilmeier; Geoffrey C Tabin; Lloyd Williams; Matt Oliva
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

4.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16

5.  Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft).

Authors:  Feyzahan Ekici; Marlene R Moster; Victor Cvintal; Wanda D Hu; Michael Waisbourd
Journal:  Clin Ophthalmol       Date:  2015-05-04

6.  Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Authors:  Oriel Spierer; Michael Waisbourd; Yitzhak Golan; Hadas Newman; Rony Rachmiel
Journal:  BMC Ophthalmol       Date:  2016-02-27       Impact factor: 2.209

7.  Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery.

Authors:  Ross M Passo; Zachary B Hoskins; Khoa D Tran; Corrina Patzer; Beth Edmunds; John C Morrison; Mansi Parikh; Hana L Takusagawa; Shandiz Tehrani
Journal:  Ophthalmol Ther       Date:  2019-06-06

8.  Short-Term Outcomes of KeraSys Patch Graft for Glaucoma Drainage Devices: A Case Series.

Authors:  Kundandeep S Nagi; Ricardo J Cumba; Nicholas P Bell; Lauren S Blieden; Alice Z Chuang; Kimberly A Mankiewicz; Donna Nguyen; Robert M Feldman
Journal:  J Ophthalmol       Date:  2013-03-17       Impact factor: 1.909

9.  New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

Authors:  Tamara L Berezina; Robert D Fechtner; Amir Cohen; Eliott E Kim; David S Chu
Journal:  J Curr Glaucoma Pract       Date:  2015-09-25

10.  Patch graft using collagen matrix (Ologen) for glaucoma drainage device exposure in a patient with Boston Keratoprosthesis type 1.

Authors:  Samir Jabbour; Mark R Lesk; Mona Harissi-Dagher
Journal:  Am J Ophthalmol Case Rep       Date:  2018-08-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.