Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery.

Ross M Passo1, Zachary B Hoskins2, Khoa D Tran3, Corrina Patzer3, Beth Edmunds2, John C Morrison2, Mansi Parikh2, Hana L Takusagawa2, Shandiz Tehrani2.   

Abstract

INTRODUCTION: Patch graft erosion and implant exposure is a known complication of glaucoma drainage device (GDD) surgery. Recently, electron beam (e-beam) irradiated corneal tissue ha s become available; however, limited data exist on the rates of erosion for e-beam irradiated corneal grafts compared to traditional scleral grafts after GDD surgery.
METHODS: This retrospective study examines the records of 253 eyes from 225 adult subjects who underwent GDD surgery with either e-beam irradiated corneal or scleral grafts at the Casey Eye Institute by five surgeons between April 22, 2014 and October 11, 2017. Surgical procedures and the occurrence of graft erosion were determined using billing codes and verified by manual review of electronic health records.
RESULTS: The average age at the time of surgery was 61.3 ± 17.5 years (n = 200) and 60.8 ± 16.8 years (n = 53) for the e-beam irradiated cornea and sclera groups, respectively. The average follow-up time post-surgery was 416 ± 345 days and 495 ± 343 days for the e-beam irradiated cornea and sclera groups, respectively. There were no statistically significant differences in sex, age, follow-up time, and glaucoma diagnosis between the groups; however, the e-beam irradiated cornea group was statistically more likely to have an Ahmed implant as compared to the sclera group. No erosion events were noted in either group.
CONCLUSION: e-Beam irradiated corneal grafts were used 3.8 times more frequently relative to scleral grafts, yet there were no cases of graft erosion in either group during the follow-up period.

Entities:  

Keywords:  Corneal patch graft; Glaucoma drainage device (GDD); Graft erosion; Scleral patch graft; Tube exposure

Year:  2019        PMID: 31172462      PMCID: PMC6692416          DOI: 10.1007/s40123-019-0190-x

Source DB:  PubMed          Journal:  Ophthalmol Ther


Introduction

Glaucoma drainage device (GDD) surgeries have become a mainstay for glaucoma treatment [1, 2] but carry the risk of implant exposure, a serious complication that can result in postoperative endophthalmitis [3-5]. To prevent this, a variety of materials have been used as grafts to cover and prevent exposure of drainage tubes, including sclera [6], fresh cornea [7, 8], glycerin-preserved cornea [9], pericardium [10], fascia lata [11], dura mater [12], porcine intestinal submucosa [13], and amniotic membrane [14]. More recently, electron beam (e-beam) irradiated corneal grafts have become available and widely used for ophthalmic applications such as lamellar corneal grafts and GDD patch grafts [15]. Corneal grafts have a variety of advantages over other traditional tissues. One major advantage of e-beam irradiated corneas is that they are sterile and arrive at the operating room ready to be transplanted without further reconstitution such as required with alcohol- and glycerin-preserved tissues. Furthermore, these grafts can be stored at room temperature for up to 2 years, making them suitable for both planned and emergency procedures. In addition, the clear corneal tissue allows for easy visualization of the tube following GDD surgery, as well as postsurgical inspection of suture retention and laser suture lysis [7] when desired. Finally, the clear material also makes for desirable cosmetic outcomes from a patient perspective. Over the past several years, e-beam irradiated corneal grafts used for GDD have increased in popularity and have become the second most transplanted tissue type behind corneas used for intermediate transplantation [16]. Despite this increased utility, limited data exist on the rates of erosion for e-beam irradiated corneal grafts after GDD surgery compared to gamma-irradiated scleral grafts. Thus, we performed a single-center retrospective analysis of early surgical outcomes and erosion rates for e-beam irradiated corneas and scleral patch grafts used in GDD surgery.

Methods

Inclusion Criteria and Graft Materials

All adult patients (age ≥ 18) who underwent GDD surgery at the Casey Eye Institute (Oregon Health and Science University) by five surgeons between April 22, 2014 and October 11, 2017 were included in this retrospective study. Patients were identified by billing codes for GDD surgery. Erosion events were identified as any billing code for further GDD and/or GDD revision surgery after initial GDD surgery. Once identified, electronic health records of all adult patients were retrospectively reviewed manually to confirm inclusion criteria. All corneal grafts were obtained from Lions VisionGift (halo™; Portland, OR, USA). Gamma-irradiated scleral grafts were obtained from New World Medical (Rancho Cucamonga, CA, USA). All procedures were in accordance with the Institutional Review Board of Oregon Health and Science University (FWA00000161; IRB00000471) and with the Helsinki Declaration of 1964, as revised in 2013, concerning human and animal rights. Springer’s policy concerning informed consent has been followed. Informed consent was obtained from all human subjects.

Surgical Procedure

GDD implants (Ahmed model S2, New World Medical, or Baerveldt model 350 from Advanced Medical Optics, Santa Ana, CA, USA) were surgically implanted and secured to the sclera using 8-0 nylon suture (94.5% in superotemporal, 2.8% in inferonasal, 2.0% in superonasal, and 0.8% in inferotemporal quadrant). Patch grafts were soaked in sterile balanced saline solution immediately prior to implantation and were sutured over the tube portion of the GDD with 8-0 nylon or 9-0 vicryl sutures, based on surgeon preference. All patients received subconjunctival injections of ophthalmic cefazolin and dexamethasone at the time of surgery, with the exception of patients who had a history of sensitivity/allergies to the aforementioned medications.

Follow-up

Subjects underwent routine clinical follow-up post GDD implantation, including at least 1 day, 1 week, and 1 month postoperatively, and subsequently every 3–6 months depending on the needs of the patient (except when lost to follow-up). Follow-up examinations included routine care for postsurgical glaucoma patients, including a detailed slit lamp examination of the patch graft, overlying conjunctiva, and, when accessible, the GDD implant itself. All patients received routine postoperative topical ofloxacin and prednisolone acetate taper, with the exception of patients who had a history of sensitivity/allergies to the aforementioned medications.

Statistics

Two-tailed t test was used to compare subject ages, follow-up time, and graft erosion rate. Fisher’s exact t test was used to compare subject sexes and implant type. Numerical values are shown as mean ± standard deviation, with statistical significance defined as p < 0.05.

Results

A total of 253 eyes in 225 adult patients who underwent GDD surgery between April 22, 2014 and October 11, 2017 were included in this retrospective study. Of those, 200 cases (79.1%) received e-beam irradiated corneal grafts as GDD patch grafts, while the remainder received scleral patch grafts. Mean age at time of initial GDD surgery was 61.3 ± 17.5 years and 60.8 ± 16.8 years for the e-beam irradiated cornea and sclera groups, respectively. Baseline patient characteristics between e-beam irradiated corneal graft and scleral graft recipients were not significantly different (Table 1). The average follow-up time post GDD surgery was 416 ± 345 days and 395 ± 343 days for the e-beam irradiated cornea and sclera groups, respectively. Ahmed implants were used in 221 (87.4%) cases and Baerveldt implants were used in 32 (12.6%) cases. Ahmed implants were more frequently used in the e-beam irradiated cornea group compared to the sclera group (90.0% vs. 77.4%, p = 0.02).
Table 1

Baseline characteristics and graft erosion rates of GDD surgeries using e-beam irradiated corneal grafts compared to gamma-irradiated scleral grafts

Recipient characteristicse-Beam irradiated corneal graftGamma-irradiated scleral graftp value
Age, mean ± SD61.3 ± 17.560.8 ± 16.80.86
Recipients, n20053
Female, n (%)99 (49.5)27 (50.9)1.0
Male, n (%)101 (50.5)26 (49.1)
Follow-up (days), mean ± SD416 ± 345395 ± 3430.69
Range (days)1–12021–1252
Graft erosions, n (%)0 (0.0)0 (0.0)1.0

GDD glaucoma drainage device, e-beam electron beam irradiated, SD standard deviation

Baseline characteristics and graft erosion rates of GDD surgeries using e-beam irradiated corneal grafts compared to gamma-irradiated scleral grafts GDD glaucoma drainage device, e-beam electron beam irradiated, SD standard deviation Diagnoses at the time of GDD surgery included primary open-angle glaucoma (35.2%), secondary glaucoma (28.9%), uveitic glaucoma (17.0%), neovascular glaucoma (8.3%), angle closure glaucoma (6.3%), ocular hypertension (4.0%), and other (0.4%). No statistically significant differences in glaucoma diagnoses were noted between groups receiving corneal or scleral patch grafts. There were no cases of erosion recorded in either cohort during this study period.

Discussion

Our results show that e-beam irradiated corneal grafts were used 3.8 times more frequently relative to scleral grafts in GDD surgery at a single academic institution, yet no increase in the rate of corneal graft erosion was noted relative to scleral grafts during the mean follow-up period of 412 ± 344 days (13.7 ± 11.5 months). No erosion events were noted in either corneal or scleral patch graft GDD surgery in this study. Previous studies of erosion rates after GDD surgery reported a low 1.8% erosion rate in 169 cases with a mean follow-up time of 4.8 months, and a 3.1% erosion rate in 319 cases over a mean follow-up time of 15.4 months using gamma-irradiated corneal grafts [17, 18]. Additional studies reported a 1.9% erosion rate using glycerol-preserved corneas over a median follow-up period of 440 days (approximately 14.5 months) [6]. The same study reported a significantly higher erosion rate of 8.9% for pericardium rates over an 11-month follow-up period. Thus, our study results over a comparable postsurgical follow-up provide support that e-beam irradiated corneal grafts are a comparable and suitable option for GDD surgery. In addition to comparable erosion rates between e-beam irradiated corneas and other graft materials, there are other safety and convenience benefits associated with the use of e-beam corneal grafts for GDD surgery. For example, fresh or glycerin-preserved tissue that can be obtained from eye banks, while screened for infectious diseases, are not sterile and carry with them a higher risk of microbial contamination than sterile grafts [19-21]. In addition, glycerin- and alcohol-preserved grafts require additional washing and rehydration steps in the operating room that are not necessary with irradiated grafts stored in an aqueous solution. The clarity of a corneal graft can also provide long-term benefits over an opaque material such as sclera or pericardium. A previous study reports that e-beam treated corneas retained about 90% optical clarity relative to fresh corneas even after extended storage at room temperature [15]. In situations when the device is assessible, the clear cornea offers the surgeon the ability to visualize and inspect the device placement and sutures under the grafts (Fig. 1i, ii). Improved cosmesis can also be achieved with a clear corneal graft depending on the position of the implanted drainage device (Fig. 1ii, iii).
Fig. 1

Representative photographs of e-beam irradiated cornea and gamma irradiated sclera for glaucoma drainage device (GDD) patch grafts. i Intraoperative photograph of an e-beam irradiated corneal graft used to cover the GDD tube. Note the visible suture viewable under the clear corneal patch graft. ii Postoperative slit lamp photograph of an irradiated corneal graft covered by conjunctiva, 5 weeks after GDD surgery. The outlined area indicates the approximate position of the graft and the arrowheads point out sub-graft sutures which can be seen and inspected through the clear graft. iii A slit lamp photograph of a sclera patch graft used to cover a GDD

Representative photographs of e-beam irradiated cornea and gamma irradiated sclera for glaucoma drainage device (GDD) patch grafts. i Intraoperative photograph of an e-beam irradiated corneal graft used to cover the GDD tube. Note the visible suture viewable under the clear corneal patch graft. ii Postoperative slit lamp photograph of an irradiated corneal graft covered by conjunctiva, 5 weeks after GDD surgery. The outlined area indicates the approximate position of the graft and the arrowheads point out sub-graft sutures which can be seen and inspected through the clear graft. iii A slit lamp photograph of a sclera patch graft used to cover a GDD There are several limitations in our study. First, this is a retrospective analysis with a relatively short follow-up period. Loss of follow-up and incomplete electronic health record documentation may have underestimated erosion rates in our analysis. Additionally, our follow-up period may have been too short to detect erosions as this complication can occur well past our follow-up period. However, prior studies have found erosions as early as the first postoperative month [17] and 6.4 months [18] following GDD surgery. Lastly, if an erosion event occurred but was not surgically corrected, then the erosion would not have even been captured in our study. However, this would be highly unlikely, as the standard of care for an eroded graft and exposed GDD implant is surgical correction to avoid infection and endophthalmitis. Further studies with longer follow-up periods are underway to better characterize graft erosion rates in GDD surgery. Future prospective studies investigating surgical indications, complications other than erosion, and visual acuity, among other items, will further contribute to this area of research.

Conclusions

The comparable performance of e-beam irradiated corneas relative to scleral patch grafts for GDD surgery provides surgeons with another viable alternative to scleral tissue, while the sterile grafts provide an additional level of safety over fresh tissue or those preserved in glycerin.
  18 in total

1.  Tube erosion following insertion of a glaucoma drainage device with a pericardial patch graft.

Authors:  P J Lama; R D Fechtner
Journal:  Arch Ophthalmol       Date:  1999-09

Review 2.  Complications of glaucoma drainage device surgery: a review.

Authors:  Michael Giovingo
Journal:  Semin Ophthalmol       Date:  2014 Sep-Nov       Impact factor: 1.975

3.  Use of amniotic membrane graft in glaucoma shunt surgery.

Authors:  Aashish Anand; Hosam Sheha; Christopher C Teng; Jeffrey M Liebmann; Robert Ritch; Celso Tello
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011 May-Jun

Review 4.  Endophthalmitis associated with the Ahmed glaucoma valve implant.

Authors:  A A Al-Torbak; S Al-Shahwan; I Al-Jadaan; A Al-Hommadi; D P Edward
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

5.  Inactivation Effect of Standard and Fractionated Electron Beam Irradiation on Enveloped and Non-Enveloped Viruses in a Tendon Transplant Model.

Authors:  Tanja Schmidt; Arnd T Hoburg; Uwe Gohs; Wolfgang Schumann; Jung-Won Sim-Brandenburg; Andreas Nitsche; Sven Scheffler; Axel Pruss
Journal:  Transfus Med Hemother       Date:  2012-01-20       Impact factor: 3.747

6.  The Ahmed Baerveldt Comparison Study methodology, baseline patient characteristics, and intraoperative complications.

Authors:  Keith Barton; Steven J Gedde; Donald L Budenz; William J Feuer; Joyce Schiffman
Journal:  Ophthalmology       Date:  2010-10-08       Impact factor: 12.079

7.  Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery.

Authors:  E Gutiérrez-Díaz; M Montero-Rodríguez; E Mencía-Gutiérrez; A Cabello; J Monescillo
Journal:  Eur J Ophthalmol       Date:  2005 May-Jun       Impact factor: 2.597

8.  Corneal patch graft repair of exposed glaucoma drainage implants.

Authors:  Mandeep Singh; Paul T K Chew; Donald Tan
Journal:  Cornea       Date:  2008-12       Impact factor: 2.651

9.  Outcomes of shunt tube coverage with glycerol preserved cornea versus pericardium.

Authors:  Eric Wigton; Jason C Swanner; Wade Joiner; Alex Feldman; Gerald McGwin; Carrie Huisingh; Christine A Curcio; Christopher A Girkin
Journal:  J Glaucoma       Date:  2014 Apr-May       Impact factor: 2.503

10.  Sutureless human sclera donor patch graft for Ahmed glaucoma valve.

Authors:  Lucio Zeppa; Mario R Romano; Luigi Capasso; Achille Tortori; Mara A Majorana; Ciro Costagliola
Journal:  Eur J Ophthalmol       Date:  2010 May-Jun       Impact factor: 2.597

View more
  1 in total

1.  Preserved Corneal Lamellar Grafting Reduces Inflammation and Promotes Wound Healing in a Scleral Defect Rabbit Model.

Authors:  Kyoung Woo Kim; Jin Suk Ryu; Jun Yeob Kim; Mee Kum Kim
Journal:  Transl Vis Sci Technol       Date:  2020-06-29       Impact factor: 3.283

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.