Literature DB >> 19021266

Different collection tubes in cardiac biomarkers detection.

Massimo Daves1, Diego Trevisan, Roberto Cemin.   

Abstract

The role played by different collection tubes is one of the more frequently forgotten parameters, which influences the quality of laboratory results.We aimed to determine whether there is a significant difference in assay of myoglobin, cardiac troponin I, and CK-MB depending on the presence of anticoagulant and gel separator in the collecting tubes.Blood samples were collected in 40 consecutive patients admitted for acute coronary syndrome. The samples were taken at the same moment in three different tubes (tubes without anticoagulant and with gel separator, heparin tubes with gel separator and heparin tubes without gelseparator;Venosafe, Terumo Europe, Leuven Belgium). Myoglobin, CK-MB and cardiac troponin I were measured with a double side (sandwich) chemiluminescent immuenzymatic assay (Access Myoglobin, Access CK-MB, Access AccuTnI).Cardiac troponin I was not influenced by the type of collection tube used. On the contrary, myoglobin and CK-MB showed a statistical difference depending on the test tube. In particular, there was a significant difference between tubes without anticoagulant and with gel separator and tubes with heparin and without gel.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19021266      PMCID: PMC6648962          DOI: 10.1002/jcla.20277

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  15 in total

1.  Troponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.

Authors:  W Gerhardt; G Nordin; A K Herbert; B L Burzell; A Isaksson; E Gustavsson; S Haglund; M Müller-Bardorff; H A Katus
Journal:  Clin Chem       Date:  2000-06       Impact factor: 8.327

2.  Elevated results in a vitamin B12 assay when using serum separator blood collection tubes.

Authors:  I Lowrey; G Smith
Journal:  Ann Clin Biochem       Date:  2003-09       Impact factor: 2.057

3.  Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis.

Authors:  Jean-Marie Boeynaems; Anne De Leener; Barbara Dessars; Hector Rodriguez Villa-Lobos; Jean-Claude Aubry; Frédéric Cotton; Philippe Thiry
Journal:  Clin Chem Lab Med       Date:  2004-01       Impact factor: 3.694

4.  Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations.

Authors:  B M Hill; R H Laessig; D D Koch; D J Hassemer
Journal:  Clin Chem       Date:  1992-08       Impact factor: 8.327

5.  False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma.

Authors:  L A Cole; K M Rinne; S Shahabi; A Omrani
Journal:  Clin Chem       Date:  1999-02       Impact factor: 8.327

6.  Comparison of cardiac troponin I levels in serum and sodium-citrate plasma using the ACCESS 2 immunoassay.

Authors:  Yu-Sin Wang; Chen-Fen Feng; Tze-Kiong Er; Li-Yu Tsai; Chian-Yu Chen; Shun-Jen Chang; Bai-Hsiun Chen
Journal:  Ann Clin Lab Sci       Date:  2005       Impact factor: 1.256

Review 7.  Acute coronary syndromes. The diagnostic role of troponins.

Authors:  C W Hamm
Journal:  Thromb Res       Date:  2001-09-30       Impact factor: 3.944

8.  Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents.

Authors:  Raffick A R Bowen; Chi Vu; Alan T Remaley; Glen L Hortin; Gyorgy Csako
Journal:  Clin Chim Acta       Date:  2006-11-28       Impact factor: 3.786

Review 9.  The increasing impact of laboratory medicine on clinical cardiology.

Authors:  Aldo Clerico
Journal:  Clin Chem Lab Med       Date:  2003-07       Impact factor: 3.694

10.  Collection tubes with or without gel separator did not interfere with detection of rubella virus antibodies IgM and IgG.

Authors:  L C Oliveira; K H Kawasato; M S Otta; L P Lima; T S Okay
Journal:  J Clin Lab Anal       Date:  2007       Impact factor: 2.352

View more
  2 in total

Review 1.  Pre-analytic variability in cardiovascular biomarker testing.

Authors:  Roberto Cemin; Massimo Daves
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

Review 2.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.