Literature DB >> 17234171

Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents.

Raffick A R Bowen1, Chi Vu, Alan T Remaley, Glen L Hortin, Gyorgy Csako.   

Abstract

BACKGROUND: Besides total triiodothyronine (TT3), total free fatty acids (FFA) concentrations were higher with serum separator tube (SST) than Vacuette tubes.
METHODS: The effects of surfactant, rubber stopper, and separator gel from various tubes were investigated on FFA, beta-hydroxybutyrate (beta-HB), and TT3 with 8 different tube types in blood specimens of apparently healthy volunteers.
RESULTS: Compared to Vacuette tubes, serum FFA and TT3 concentrations were significantly higher in SST than glass tubes. Reformulated SST eliminated the increase in TT3 but not FFA. No significant difference was observed for beta-HB concentration among tube types. Surfactant and rubber stoppers from the different tube types significantly increased TT3 but not FFA and beta-HB concentrations. Agitation of whole blood but not serum or plasma specimens with separator gel from SST, reformulated SST and plasma preparation tube (PPT) tubes compared to Vacuette tubes gave higher FFA but not beta-HB levels.
CONCLUSIONS: Unidentified component(s) from the separator gel in SST, reformulated SST and PPT tubes cause falsely high FFA concentration. In contrast to TT3, falsely high FFA results require exposure of whole blood and not serum to tube constituent(s). The approach employed here may serve as a model for assessing interference(s) from tube constituent(s).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17234171     DOI: 10.1016/j.cca.2006.11.020

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Different collection tubes in cardiac biomarkers detection.

Authors:  Massimo Daves; Diego Trevisan; Roberto Cemin
Journal:  J Clin Lab Anal       Date:  2008       Impact factor: 2.352

2.  Blood collection tube-related alterations in analyte concentrations in quality control material and serum specimens.

Authors:  Raffick A R Bowen; Annie Sattayapiwat; Verena Gounden; Alan T Remaley
Journal:  Clin Biochem       Date:  2013-11-14       Impact factor: 3.281

3.  A comparative study on the effect of blood collection tubes on stress oxidative markers.

Authors:  Alireza Bastin; Saba Fooladi; Amir Hossein Doustimotlagh; Sina Vakili; Amir Hashem Aminizadeh; Sanaz Faramarz; Hamidreza Shiri; Mohammad Hadi Nematollahi
Journal:  PLoS One       Date:  2022-04-06       Impact factor: 3.240

Review 4.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  4 in total