Literature DB >> 19012997

Quantification of cancellous bone-compaction due to DHS Blade insertion and influence upon cut-out resistance.

Markus Windolf1, Raphael Muths, Volker Braunstein, Boyko Gueorguiev, Markus Hänni, Karsten Schwieger.   

Abstract

BACKGROUND: Compaction of cancellous bone is believed to prevent cut-out. This in vitro study quantified the compaction in the femoral head due to insertion of a dynamic hip screw-blade with and without predrilling and investigated the resulting implant anchorage under cyclic loading.
METHODS: Eight pairs of human cadaveric femoral heads were instrumented with a dynamic hip screw-blade made of Polyetheretherketon. Pairwise instrumentation was performed either with or without predrilling the specimens. CT scanning was performed before and after implantation, to measure bone-compaction. Subsequently the implant was removed and a third scan was performed to analyze the relaxation of the bone structure. Commercial implants were reinserted and the specimens were cyclically loaded until onset of cut-out occurred. The bone-implant interface was monitored by means of fluoroscopic imaging throughout the experiment. Paired t-tests were performed to identify differences regarding compaction, relaxation and cycles to failure.
FINDINGS: Bone density in the surrounding of the implant increased about 30% for the non-predrilled and 20% for the predrilled group when inserting the implant. After implant removal the predrilled specimens fully relaxed; the non-predrilled group showed about 10% plastic deformation. No differences were found regarding cycles to failure (P=0.32).
INTERPRETATION: Significant bone-compaction due to blade insertion was verified. Even though compaction was lower when predrilling the specimens, mainly elastic deformation was present, which is believed to primarily enhance the implant anchorage. Cyclic loading tests confirmed this thesis. The importance of the implantation technique with regard to predrilling is therefore decreased.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19012997     DOI: 10.1016/j.clinbiomech.2008.09.005

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  26 in total

1.  The locking attachment plate for proximal fixation of periprosthetic femur fractures--a biomechanical comparison of two techniques.

Authors:  Mark Lenz; Markus Windolf; Thomas Mückley; Gunther O Hofmann; Michael Wagner; Robert G Richards; Karsten Schwieger; Boyko Gueorguiev
Journal:  Int Orthop       Date:  2012-05-27       Impact factor: 3.075

2.  Analysis of sacro-iliac joint screw fixation: does quality of reduction and screw orientation influence joint stability? A biomechanical study.

Authors:  Gaston Camino Willhuber; Ivan Zderic; Florian Gras; Dieter Wahl; Carlos Sancineto; Jorge Barla; Markus Windolf; Robert Geoff Richards; Boyko Gueorguiev
Journal:  Int Orthop       Date:  2015-10-05       Impact factor: 3.075

3.  A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults.

Authors:  Babak Siavashi; Arash Aalirezaei; Mersad Moosavi; Mohammad Reza Golbakhsh; Dariush Savadkoohi; Mohammad Javad Zehtab
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

4.  A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures.

Authors:  Sascha Rausch; Kajetan Klos; Uwe Wolf; Marc Gras; Paul Simons; Steffen Brodt; Markus Windolf; Boyko Gueorguiev
Journal:  Int Orthop       Date:  2014-04-25       Impact factor: 3.075

5.  Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

Authors:  Tim Pohlemann; Boyko Gueorguiev; Yash Agarwal; Dieter Wahl; Christoph Sprecher; Karsten Schwieger; Mark Lenz
Journal:  Int Orthop       Date:  2015-01-28       Impact factor: 3.075

6.  Biomechanical performance of different cable and wire cerclage configurations.

Authors:  Mark Lenz; Stephan Marcel Perren; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Boyko Gueorguiev; Markus Windolf
Journal:  Int Orthop       Date:  2012-11-10       Impact factor: 3.075

7.  Fatigue performance of angle-stable tibial nail interlocking screws.

Authors:  Mark Lenz; Boyko Gueorguiev; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Dankward Höntzsch; Markus Windolf
Journal:  Int Orthop       Date:  2012-08-09       Impact factor: 3.075

8.  Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration.

Authors:  Markus Windolf; Edgardo Ramos Maza; Boyko Gueorguiev; Volker Braunstein; Karsten Schwieger
Journal:  BMC Musculoskelet Disord       Date:  2010-08-04       Impact factor: 2.362

9.  [Augmentation technique on the proximal humerus].

Authors:  A Scola; F Gebhard; G Röderer
Journal:  Unfallchirurg       Date:  2015-09       Impact factor: 1.000

10.  Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.

Authors:  George K Kouvidis; Mark B Sommers; Peter V Giannoudis; Pavlos G Katonis; Michael Bottlang
Journal:  J Orthop Surg Res       Date:  2009-05-18       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.