PURPOSE: The purpose of this study was to investigate whether cement-augmented screw osteosynthesis results in stability comparable to conventional fixed-angle locking plate osteosynthesis using cadaveric bones to model a Sanders type 2B fracture. METHODS: Seven pairs of fresh frozen human calcanei and the corresponding tali were used. The specimens were assigned pairwise to two study groups in a randomised manner. In order to determine the initial quasi-static stiffness of the bone-implant construct, testing commenced with quasi-static compression ramp loading; subsequently, sinusoidal cyclic compression loading at 2 Hz was performed until construct failure occurred. Initial dynamic stiffness (cycle 1), range of motion (ROM), cycles to failure and load to failure were determined from the machine data during the cyclic test. In addition, at 250-cycle intervals, Böhler's angle and the critical angle of Gissane were determined on mediolateral X-rays shot with a triggered C-arm; 5° angle flattening was arbitrarily defined as a failure criterion. RESULTS: Bone mineral density was normally distributed without significant differences between the groups. The augmented screw osteosynthesis resulted in higher stiffness values compared to the fixed-angle locking plate osteosynthesis. The fracture fragment motion in the locking plate group was significantly higher compared to the group with augmented screw osteosynthesis. CONCLUSIONS: The results of this study indicate that in our selected test set-up augmented screw osteosynthesis was significantly superior to the conventional fixed-angle locking plate osteosynthesis with respect to primary stability and ROM during cyclic testing.
PURPOSE: The purpose of this study was to investigate whether cement-augmented screw osteosynthesis results in stability comparable to conventional fixed-angle locking plate osteosynthesis using cadaveric bones to model a Sanders type 2B fracture. METHODS: Seven pairs of fresh frozen human calcanei and the corresponding tali were used. The specimens were assigned pairwise to two study groups in a randomised manner. In order to determine the initial quasi-static stiffness of the bone-implant construct, testing commenced with quasi-static compression ramp loading; subsequently, sinusoidal cyclic compression loading at 2 Hz was performed until construct failure occurred. Initial dynamic stiffness (cycle 1), range of motion (ROM), cycles to failure and load to failure were determined from the machine data during the cyclic test. In addition, at 250-cycle intervals, Böhler's angle and the critical angle of Gissane were determined on mediolateral X-rays shot with a triggered C-arm; 5° angle flattening was arbitrarily defined as a failure criterion. RESULTS: Bone mineral density was normally distributed without significant differences between the groups. The augmented screw osteosynthesis resulted in higher stiffness values compared to the fixed-angle locking plate osteosynthesis. The fracture fragment motion in the locking plate group was significantly higher compared to the group with augmented screw osteosynthesis. CONCLUSIONS: The results of this study indicate that in our selected test set-up augmented screw osteosynthesis was significantly superior to the conventional fixed-angle locking plate osteosynthesis with respect to primary stability and ROM during cyclic testing.
Authors: Martinus Richter; Thomas Gosling; Stefan Zech; Mohamad Allami; Jens Geerling; Patricia Droste; Christian Krettek Journal: Foot Ankle Int Date: 2005-04 Impact factor: 2.827
Authors: D B Thordarson; T P Hedman; D N Yetkinler; E Eskander; T N Lawrence; R D Poser Journal: J Bone Joint Surg Am Date: 1999-02 Impact factor: 5.284
Authors: Jon E Hammarstedt; James T Redshaw; Patrick J Schimoler; Edward R Westrick; Derek Andreini; Alexander Kharlamov; Mark Carl Miller Journal: J Clin Orthop Trauma Date: 2022-08-27
Authors: Robert-Jan O de Muinck Keizer; Manouk Backes; Siem A Dingemans; J Carel Goslings; Tim Schepers Journal: Int Orthop Date: 2016-06-24 Impact factor: 3.075
Authors: Martin Eichinger; Alexander Brunner; Hannes Stofferin; Andreas Bölderl; Michael Blauth; Werner Schmölz Journal: Int Orthop Date: 2018-10-10 Impact factor: 3.075
Authors: Konrad F Fuchs; Philipp Heilig; Miriam McDonogh; Sebastian Boelch; Uwe Gbureck; Rainer H Meffert; Stefanie Hoelscher-Doht; Martin C Jordan Journal: J Orthop Surg Res Date: 2020-11-14 Impact factor: 2.359