Literature DB >> 19011182

Coronary stent fracture: detection with 64-section multidetector CT angiography in patients and in vitro.

Han Byeol Lim1, Gham Hur, Su Young Kim, Yong Hoon Kim, Sung Uk Kwon, Won Ro Lee, Soon Joo Cha.   

Abstract

PURPOSE: To evaluate 64-section multidetector coronary computed tomographic (CT) angiography for the depiction of coronary stent fracture in patients and in vitro.
MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and informed patient consent was waived. The coronary CT angiograms obtained in 371 consecutive patients (268 men, 103 women; mean age, 62.9 years) with 545 stents were reviewed. All patients with stent fractures underwent conventional coronary angiography and/or fluoroscopy as part of their medical care. In phantom studies, magnified radiographs of three types of drug-eluting stents in their fully expanded, maximally bent, and unrolled states were obtained. CT angiography and fluoroscopy of a water phantom that contained two drug-eluting stents--Cypher and Taxus devices--with four fractures each were performed, and two radiologists blinded to the fracture information evaluated the images.
RESULTS: Twenty-four stents with fractures were identified. Eighteen fractured stents (13 Cypher, four Taxus, one S670) in 14 patients were detected with CT angiography; six (33%; two Cypher, four Taxus) of these 18 stents in five (36%) patients were not detected on conventional angiograms at the initial readings. Six fractured stents showed significant (>50%) recurrent in-stent stenosis. Of 58 arteries with overlapping stent placements, eight (14%) had fractures involving 11 stents. In the in vitro studies, 57 stent fractures (31 Cypher, 26 Taxus) were detected with CT angiography and 38 (18 Cypher, 20 Taxus) were detected with fluoroscopy.
CONCLUSION: Coronary CT angiography depicts stent fractures in patients and phantoms, even those fractures that are not clearly depicted by conventional angiography. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/249/3/810/DC1. RSNA, 2008

Entities:  

Mesh:

Year:  2008        PMID: 19011182     DOI: 10.1148/radiol.2493088035

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study.

Authors:  Xinghua Zhang; Li Yang; Haiyue Ju; Fan Zhang; Jian Wu; Bin He; Yundai Chen
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

2.  Stent fracture and longitudinal compression detected on coronary CT angiography in the first- and new-generation drug-eluting stents.

Authors:  Mi Sun Chung; Dong Hyun Yang; Young-Hak Kim; Jae-Hyung Roh; Jihyun Song; Joon-Won Kang; Jung-Min Ahn; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Cheol Whan Lee; Seong-Wook Park; Seung-Jung Park; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-26       Impact factor: 2.357

3.  Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography.

Authors:  Yung-Liang Wan; Pei-Kwei Tsay; Chun-Chi Chen; Yu-Hsiang Juan; Yu-Chieh Huang; Wen-Hui Chan; Ming-Shien Wen; I-Chang Hsieh
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-22       Impact factor: 2.357

4.  Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: a multislice computed tomography study.

Authors:  Tsuyoshi Ito; Masashi Kimura; Mariko Ehara; Mitsuyasu Terashima; Kenya Nasu; Yoshihisa Kinoshita; Maoto Habara; Etsuo Tsuchikane; Takahiko Suzuki
Journal:  Eur Radiol       Date:  2014-02-25       Impact factor: 5.315

5.  Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT.

Authors:  Hye-Joung Eom; Dong Hyun Yang; Young-Hak Kim; Jae-Hyung Roh; Jihoon Kweon; Soo-Jin Kang; Namkug Kim; Joon-Won Kang; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-09       Impact factor: 2.357

6.  High-resolution ex vivo magnetic resonance angiography: a feasibility study on biological and medical tissues.

Authors:  Anne S Rasmussen; Henrik Lauridsen; Christoffer Laustsen; Bjarke G Jensen; Steen F Pedersen; Lars Uhrenholt; Lene W T Boel; Niels Uldbjerg; Tobias Wang; Michael Pedersen
Journal:  BMC Physiol       Date:  2010-03-12

7.  Fracture of zotarolimus-eluting stent after implantation.

Authors:  Meng-Chieh Wu; Chen-Chuan Cheng; Tsuei-Yuan Huang
Journal:  Tex Heart Inst J       Date:  2009

8.  CT Imaging of Coronary Stents: Past, Present, and Future.

Authors:  Andreas H Mahnken
Journal:  ISRN Cardiol       Date:  2012-09-11

9.  A case of a zotarolimus-eluting stent fracture in the left anterior descending artery in a patient undergoing hemodialysis.

Authors:  In Hye Cha; Seong Hwan Kim; Sang Yup Lim; Jeong Chun Ahn; Woo Hyuk Song
Journal:  Chonnam Med J       Date:  2011-04-26

10.  Stent fracture: how frequently is it recognized?

Authors:  Mohammed Khalil Mohsen; Awad Alqahtani; Jassim Al Suwaidi
Journal:  Heart Views       Date:  2013-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.