Literature DB >> 27503550

Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT.

Hye-Joung Eom1, Dong Hyun Yang2, Young-Hak Kim3, Jae-Hyung Roh3, Jihoon Kweon3, Soo-Jin Kang3, Namkug Kim1, Joon-Won Kang1, Tae-Hwan Lim1.   

Abstract

The aim of this study is to analyze post-bifurcation coronary stent morphology in vitro using dual-source CT and validate those findings using micro-CT. Nine silicon coronary artery phantoms simulating main branch (MB) and side branch (SB) were prepared using a 3-D printer. After bifurcation stenting using Crush, Culotte, and T-stenting technique, in vitro CT imaging was conducted using both dual-source CT and micro-CT. Morphological change of the bifurcation stent including crushed segment and floating stent strut were evaluated. Dual-source CT was able to demonstrate morphologic changes of bifurcation stents and was comparable to micro-CT. In stents with Crush and T-stenting methods, crushed segment appeared denser and thicker than other stent parts and was located at MB side in all phantoms. Floating strut was observed in half of the phantoms with Crush technique and all phantoms with T-stenting. Parameters measured in both dual-source CT and micro-CT showed good correlation and high agreement (limits of agreement and correlation for length, perimeter and area, 0.3 ± 3.5, 0.5 ± 2.1 mm, and 0.0 ± 1.5 mm², r = 0.76, 0.92, and 0.91). The morphology of post-bifurcation stent on dual-source CT correlates well with that of micro-CT in the coronary artery phantom. Coronary CT angiography may be a feasible method for the evaluation of stent morphology in patients who underwent bifurcation stenting.

Entities:  

Keywords:  Bifurcation stent; CT; Micro CT

Mesh:

Year:  2016        PMID: 27503550     DOI: 10.1007/s10554-016-0953-6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  22 in total

1.  Kissing balloon or sequential dilation of the side branch and main vessel for provisional stenting of bifurcations: lessons from micro-computed tomography and computational simulations.

Authors:  Nicolas Foin; Ryo Torii; Peter Mortier; Mathieu De Beule; Nicola Viceconte; Pak Hei Chan; Justin E Davies; Xiao Yun Xu; Rob Krams; Carlo Di Mario
Journal:  JACC Cardiovasc Interv       Date:  2012-01       Impact factor: 11.195

2.  Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.

Authors:  Andrew R Williams; Bon-Kwon Koo; Timothy J Gundert; Peter J Fitzgerald; John F LaDisa
Journal:  J Appl Physiol (1985)       Date:  2010-05-27

Review 3.  Comprehensive overview of definitions for optical coherence tomography-based plaque and stent analyses.

Authors:  Luca Di Vito; Joo Heung Yoon; Koji Kato; Taishi Yonetsu; Rocco Vergallo; Marco Costa; Hiram G Bezerra; Eloisa Arbustini; Jagat Narula; Filippo Crea; Francesco Prati; Ik-Kyung Jang
Journal:  Coron Artery Dis       Date:  2014-03       Impact factor: 1.439

Review 4.  Bifurcation stenting: current strategies and new devices.

Authors:  A Latib; A Colombo; G M Sangiorgi
Journal:  Heart       Date:  2008-09-23       Impact factor: 5.994

5.  ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 Appropriate Use Criteria for Cardiac Computed Tomography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance.

Authors:  Allen J Taylor; Manuel Cerqueira; John McB Hodgson; Daniel Mark; James Min; Patrick O'Gara; Geoffrey D Rubin
Journal:  J Cardiovasc Comput Tomogr       Date:  2010-11-23

6.  Computational fluid dynamic simulations of image-based stented coronary bifurcation models.

Authors:  Claudio Chiastra; Stefano Morlacchi; Diego Gallo; Umberto Morbiducci; Rubén Cárdenes; Ignacio Larrabide; Francesco Migliavacca
Journal:  J R Soc Interface       Date:  2013-05-15       Impact factor: 4.118

7.  Optical coherence tomography (OCT) strut-level analysis of drug-eluting stents (DES) in human coronary bifurcations.

Authors:  Hiroyuki Kyono; Giulio Guagliumi; Vasile Sirbu; Noah Rosenthal; Satoko Tahara; Giuseppe Musumeci; Antonio Trivisonno; Hiram G Bezerra; Marco A Costa
Journal:  EuroIntervention       Date:  2010-05       Impact factor: 6.534

8.  Accuracy of in vivo coronary plaque morphology assessment: a validation study of in vivo virtual histology compared with in vitro histopathology.

Authors:  Kenya Nasu; Etsuo Tsuchikane; Osamu Katoh; D Geoffrey Vince; Renu Virmani; Jean-François Surmely; Akira Murata; Yoshihiro Takeda; Tatsuya Ito; Mariko Ehara; Tetsuo Matsubara; Mitsuyasu Terashima; Takahiko Suzuki
Journal:  J Am Coll Cardiol       Date:  2006-05-30       Impact factor: 24.094

9.  Coronary stent fracture: detection with 64-section multidetector CT angiography in patients and in vitro.

Authors:  Han Byeol Lim; Gham Hur; Su Young Kim; Yong Hoon Kim; Sung Uk Kwon; Won Ro Lee; Soon Joo Cha
Journal:  Radiology       Date:  2008-12       Impact factor: 11.105

10.  Location of side branch access critically affects results in bifurcation stenting: Insights from bench modeling and computational flow simulation.

Authors:  N Foin; R Torii; E Alegria; S Sen; R Petraco; S Nijjer; M Ghione; J E Davies; C Di Mario
Journal:  Int J Cardiol       Date:  2013-05-25       Impact factor: 4.164

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.