Surgical clips for position verification and correction of non-rigid breast tissue in simultaneously integrated boost (SIB) treatments.

Joan Penninkhof1, Sandra Quint, Hans de Boer, Jan Willem Mens, Ben Heijmen, Maarten Dirkx.   

Abstract

BACKGROUND AND
PURPOSE: The aim of this study is to investigate whether surgical clips in the lumpectomy cavity are representative for position verification of both the tumour bed and the whole breast in simultaneously integrated boost (SIB) treatments.
MATERIALS AND METHODS: For a group of 30 patients treated with a SIB technique, kV and MV planar images were acquired throughout the course of the fractionated treatment. The 3D set-up error for the tumour bed was derived by matching the surgical clips (3-8 per patient) in two almost orthogonal planar kV images. By projecting the 3D set-up error derived from the planar kV images to the (u, v)-plane of the tangential beams, the correlation with the 2D set-up error for the whole breast, derived from the MV EPID images, was determined. The stability of relative clip positions during the fractionated treatment was investigated. In addition, for a subgroup of 15 patients, the impact of breathing was determined from fluoroscopic movies acquired at the linac.
RESULTS: The clip configurations were stable over the course of radiotherapy, showing an inter-fraction variation (1 SD) of 0.5mm on average. Between the start and the end of the treatment, the mean distance between the clips and their center of mass was reduced by 0.9 mm. A decrease larger than 2mm was observed in eight patients (17 clips). The top-top excursion of the clips due to breathing was generally less than 2.5mm in all directions. The population averages of the difference (+/-1 SD) between kV and MV matches in the (u, v)-plane were 0.2+/-1.8mm and 0.9+/-1.5mm, respectively. In 30% of the patients, time trends larger than 3mm were present over the course of the treatment in either or in both kV and MV match results. Application of the NAL protocol based on the clips reduced the population mean systematic error to less than 2mm in all directions, both for the tumour bed and the whole breast. Due to the observed time trends, these systematic errors can be further reduced to about 1mm by using an eNAL protocol instead.
CONCLUSIONS: The relative positions of implanted surgical clips in the lumpectomy cavity after breast-conserving surgery remain stable during the course of radiotherapy treatment. Application of a NAL or eNAL set-up correction protocol based on surgical clips allows for adequate treatment of both the tumour bed and the whole breast with tight CTV-PTV margins.

Entities:  

Mesh:

Year:  2008        PMID: 19010561     DOI: 10.1016/j.radonc.2008.10.009

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  11 in total

1.  Correction of systematic set-up error in breast and head and neck irradiation through a no-action level (NAL) protocol.

Authors:  Eva M Lozano; Luis A Pérez; Javier Torres; Carmen Carrascosa; Miguel Sanz; Fermín Mendicote; Antonio Gil
Journal:  Clin Transl Oncol       Date:  2011-01       Impact factor: 3.405

2.  Impact of a Novel Bioabsorbable Implant on Radiation Treatment Planning for Breast Cancer.

Authors:  Michael J Cross; Gail S Lebovic; Joseph Ross; Scott Jones; Arnold Smith; Steven Harms
Journal:  World J Surg       Date:  2017-02       Impact factor: 3.352

3.  Intensity modulated radiotherapy (IMRT) with simultaneous integrated boost (SIB) in a patient with left breast cancer and pectus excavatum.

Authors:  Ricardo Cendales; Jaider Vasquez; Juan Carlos Arbelaez; Ivan Bobadilla; Ricardo Espanol; Felipe Torres; Armando Gaitan
Journal:  Clin Transl Oncol       Date:  2012-07-19       Impact factor: 3.405

4.  Tumor bed segmentation: first step for partial breast irradiation.

Authors:  Amparo González Sanchis; Luis Brualla González; Carlos Fuster Diana; Jose Carlos Gordo Partearroyo; Andres Garcia-Vilanova Comas; Jose Luis Lopez Torrecilla; Joan Roselló Ferrando
Journal:  Clin Transl Oncol       Date:  2012-07-25       Impact factor: 3.405

5.  Clinical implementation of kilovoltage cone beam CT for the verification of sequential and integrated photon boost treatments for breast cancer patients.

Authors:  E M Donovan; I Castellano; S Eagle; E Harris
Journal:  Br J Radiol       Date:  2012-05-02       Impact factor: 3.039

6.  Evaluation of relative transmitted dose for a step and shoot head and neck intensity modulated radiation therapy using a scanning liquid ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak
Journal:  J Med Phys       Date:  2012-01

7.  Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action-level protocol in whole-breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Correlation between target motion and the dosimetric variance of breast and organ at risk during whole breast radiotherapy using 4DCT.

Authors:  Wei Wang; Jian Bin Li; Hong Guang Hu; Feng Xiang Li; Min Xu; Tao Sun; Jie Lu
Journal:  Radiat Oncol       Date:  2013-05-02       Impact factor: 3.481

9.  Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT.

Authors:  Wei Wang; Jian Bin Li; Hong Guang Hu; Tao Sun; Min Xu; Ting Yong Fan; Qian Shao
Journal:  J Radiat Res       Date:  2013-01-24       Impact factor: 2.724

10.  An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique.

Authors:  Jessica Turley; Elizabeth Claridge Mackonis
Journal:  J Med Radiat Sci       Date:  2015-08-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.