Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience.

Bernhard A Herzog1, Lars Husmann, Nina Burkhard, Oliver Gaemperli, Ines Valenta, Fuminari Tatsugami, Christophe A Wyss, Ulf Landmesser, Philipp A Kaufmann.   

Abstract

AIMS: To evaluate the accuracy of low-dose computed tomography coronary angiography (CTCA) using prospective ECG-triggering for the assessment of coronary artery disease (CAD). METHODS AND
RESULTS: A total of 30 patients (19 males, 11 females, mean age 58.8 +/- 9.9 years) underwent low-dose CTCA and invasive coronary angiography (CA) [median 2 days (0, 41)]. Before CT scanning, intravenous beta-blocker was administered in 18 of 30 patients as heart rate (HR) was >65 b.p.m., achieving a mean HR of 55.7 +/- 7.9 b.p.m. CAD was defined as coronary artery narrowing > or =50%, using CA as standard of reference. The estimated mean effective radiation dose was 2.1 +/- 0.7 mSv (range: 1.0-3.3), yielding 96.0% (383/399) of evaluable segments. On an intention-to-diagnose-base, all non-evaluative segments were included in the analysis. Vessels with a non-evaluative segment and no further finding were censored as false positive. Patient-based analysis revealed sensitivity, specificity, positive predictive value, and negative predictive value of 100, 83.3, 90.0, and 100%, respectively. The respective values per vessel were 100, 88.9, 85.7, and 100%, respectively.
CONCLUSION: Prospective ECG-triggering allows low-dose CTCA and provides high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rate.

Entities:  

Mesh:

Year:  2008        PMID: 18996954     DOI: 10.1093/eurheartj/ehn485

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  42 in total

1.  Prognostic value of CT coronary angiography: focus on obstructive vs. nonobstructive disease and on the presence of left main disease.

Authors:  E Maffei; S Seitun; C Martini; A Aldrovandi; T Arcadi; A Clemente; G Messalli; R Malagò; A Weustink; N Mollet; K Nieman; D Ardissino; P de Feyter; G Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

2.  Downstream resource utilization following hybrid cardiac imaging with an integrated cadmium-zinc-telluride/64-slice CT device.

Authors:  Michael Fiechter; Jelena R Ghadri; Mathias Wolfrum; Silke M Kuest; Aju P Pazhenkottil; Rene N Nkoulou; Bernhard A Herzog; Cathérine Gebhard; Tobias A Fuchs; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-12-06       Impact factor: 9.236

Review 3.  Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-04       Impact factor: 2.357

4.  320-detector CT coronary angiography with prospective and retrospective electrocardiogram gating in a single heartbeat: comparison of image quality and radiation dose.

Authors:  J Qin; L-Y Liu; Y Fang; J-M Zhu; Z Wu; K-S Zhu; J-S Zhang; H Shan
Journal:  Br J Radiol       Date:  2012-07       Impact factor: 3.039

5.  Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography.

Authors:  M A Kuefner; S Grudzenski; J Hamann; S Achenbach; Michael Lell; K Anders; S A Schwab; L Häberle; M Löbrich; M Uder
Journal:  Eur Radiol       Date:  2010-07-13       Impact factor: 5.315

Review 6.  Recent developments in wide-detector cardiac computed tomography.

Authors:  Sang Il Choi; Richard T George; Karl H Schuleri; Eun Ju Chun; Joao A C Lima; Albert C Lardo
Journal:  Int J Cardiovasc Imaging       Date:  2009-03-03       Impact factor: 2.357

Review 7.  Coronary CT angiography: Dose reduction strategies.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

8.  Signal density of left ventricular myocardial segments and impact of beam hardening artifact: implications for myocardial perfusion assessment by multidetector CT coronary angiography.

Authors:  Gastón A Rodríguez-Granillo; Miguel A Rosales; Elina Degrossi; Alfredo E Rodriguez
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-12       Impact factor: 2.357

9.  Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients.

Authors:  Ming-Li Sun; Bin Lu; Run-Ze Wu; Laura Johnson; Lei Han; Gang Liu; Fang-Fang Yu; Zhi-Hui Hou; Yang Gao; Hong-Yu Wang; Shiliang Jiang; Yue-Jin Yang; Shu-Bin Qiao
Journal:  Eur Radiol       Date:  2011-04-12       Impact factor: 5.315

10.  Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Authors:  Lars Husmann; Bernhard A Herzog; Nina Burkhard; Fuminari Tatsugami; Ines Valenta; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.