Literature DB >> 18983275

Detection of raised intracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children.

Nicholas A V Beare1, Sam Kampondeni, Simon J Glover, Elizabeth Molyneux, Terrie E Taylor, Simon P Harding, Malcolm E Molyneux.   

Abstract

OBJECTIVE: To evaluate optic nerve sheath (ONS) ultrasound as a non-invasive method of detecting raised intracranial pressure (ICP) and to establish normal ONS diameter data for African children.
METHOD: Children with acute neurological disease admitted to the Paediatric Department of Queen Elizabeth Central Hospital, Malawi had ultrasound measurements of ONS diameter. Controls were children admitted to the same department with non-neurological disease. The mean of three measurements of the ONS diameter was used for analysis. Children were assessed for clinical signs of raised ICP. Patients had CT brain scans if required for their normal clinical care.
RESULTS: In 14 children with neurological disease and clinical signs suggestive of raised ICP, the mean ONS diameter was 5.4 mm (range 4.3-6.2 mm). Radiological signs on CT scans substantiated the presence of raised ICP in eight (all those scanned). In seven children with neurological disease but no specific signs of raised ICP the mean ONS diameter was 3.6 mm (range 2.8-4.4 mm). None of four of these patients examined by CT scan had signs of elevated ICP. The mean ONS diameter in 30 controls without neurological disease was 3.5 mm (range 2.5-4.1 mm). If 4.2 mm is taken as the upper limit of normal the sensitivity and specificity of this test for elevated ICP is 100% and 86%, respectively.
CONCLUSION: ONS ultrasound is an accurate method for detecting raised ICP that can be applied in a broad range of settings. It has the advantages of being a non-invasive, bedside test, which can be repeated multiple times for re-evaluation.

Entities:  

Mesh:

Year:  2008        PMID: 18983275      PMCID: PMC3776606          DOI: 10.1111/j.1365-3156.2008.02153.x

Source DB:  PubMed          Journal:  Trop Med Int Health        ISSN: 1360-2276            Impact factor:   2.622


  9 in total

1.  Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults.

Authors:  S A Ballantyne; G O'Neill; R Hamilton; A S Hollman
Journal:  Eur J Ultrasound       Date:  2002-10

2.  Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests.

Authors:  H C Hansen; K Helmke
Journal:  J Neurosurg       Date:  1997-07       Impact factor: 5.115

3.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study.

Authors:  K Helmke; H C Hansen
Journal:  Pediatr Radiol       Date:  1996-10

4.  Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath.

Authors:  Michael Blaivas; Daniel Theodoro; Paul R Sierzenski
Journal:  Acad Emerg Med       Date:  2003-04       Impact factor: 3.451

5.  Transorbital optic nerve sheath ultrasonography in normal children.

Authors:  J Ballantyne; A S Hollman; R Hamilton; M S Bradnam; R Carachi; D G Young; G N Dutton
Journal:  Clin Radiol       Date:  1999-11       Impact factor: 2.350

6.  Sonographic evaluation of optic nerve diameter in children with raised intracranial pressure.

Authors:  Ashkan Akhavan Malayeri; Shirin Bavarian; Mehrzad Mehdizadeh
Journal:  J Ultrasound Med       Date:  2005-02       Impact factor: 2.153

7.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study.

Authors:  K Helmke; H C Hansen
Journal:  Pediatr Radiol       Date:  1996-10

8.  A rapid noninvasive method of detecting elevated intracranial pressure using bedside ocular ultrasound: application to 3 cases of head trauma in the pediatric emergency department.

Authors:  James W Tsung; Michael Blaivas; Arthur Cooper; Nadine R Levick
Journal:  Pediatr Emerg Care       Date:  2005-02       Impact factor: 1.454

9.  Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.

Authors:  W D Newman; A S Hollman; G N Dutton; R Carachi
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

  9 in total
  21 in total

1.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 2.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

3.  Diagnostic value of neuro-ophthalmological signs in cases of Chiari I malformation.

Authors:  Inessa Bekerman; Tal Sigal; Itzhak Kimiagar; Zina Evy Almer; Michael Vaiman
Journal:  Childs Nerv Syst       Date:  2016-11-08       Impact factor: 1.475

4.  Dynamic Optic Nerve Sheath Diameter (ONSD) guided management of raised intracranial pressure in pediatric acute liver failure.

Authors:  Priti Vijay; Bikrant Bihari Lal; Vikrant Sood; Rajeev Khanna; Yashwant Patidar; Seema Alam
Journal:  Hepatol Int       Date:  2021-02-24       Impact factor: 6.047

5.  Cerebral biometry at birth and at 4 and 8 months of age. A prospective study using US.

Authors:  Joost Gravendeel; Karen Rosendahl
Journal:  Pediatr Radiol       Date:  2010-07-30

6.  Prevalence of raised intracranial pressure in cerebral malaria detected by optic nerve sheath ultrasound.

Authors:  Nicholas A V Beare; Simon J Glover; Susan Lewallen; Terrie E Taylor; Simon P Harding; Malcolm E Molyneux
Journal:  Am J Trop Med Hyg       Date:  2012-10-01       Impact factor: 2.345

Review 7.  Non-invasive intracranial pressure assessment.

Authors:  Llewellyn C Padayachy
Journal:  Childs Nerv Syst       Date:  2016-07-21       Impact factor: 1.475

8.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Travis Pollock; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

9.  Optic nerve sheath diameter on MR imaging: establishment of norms and comparison of pediatric patients with idiopathic intracranial hypertension with healthy controls.

Authors:  B Shofty; L Ben-Sira; S Constantini; S Freedman; A Kesler
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-24       Impact factor: 3.825

10.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.