Literature DB >> 18963818

The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone.

M Motoyoshi1, M Inaba, A Ono, S Ueno, N Shimizu.   

Abstract

Cortical bone thickness (CBT) was evaluated at mini-implant placement sites in 65 orthodontic patients and was found to be directly proportional to the success rate of the mini-implant. The success rate of the mini-implant was significantly greater at sites with CBT> or =1.0mm. To examine the biomechanical effects of CBT, finite element models were made for CBT from 0.5 to 1.5mm, at 0.25-mm intervals. Cortical bone models without cancellous bone were constructed to examine the biomechanical influence on cortical bone after cancellous bone resorption. CBT influenced the stresses in the cancellous bone, but could not directly influence the stresses in the cortical bone. For CBT<1mm, the cancellous bone models exhibited von Mises stresses exceeding 6MPa, and the cortical bone models without cancellous bone showed von Mises stresses exceeding 28MPa. Greater CBT values were associated with higher mini-implant success rates. This morphometric study and mathematical simulation verify that a clinical CBT threshold of 1mm improves the success rate of mini-implants.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18963818     DOI: 10.1016/j.ijom.2008.09.006

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  32 in total

1.  Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study.

Authors:  Hemanth Tumkur Lakshmikantha; Naresh Kumar Ravichandran; Mansik Jeon; Jeehyun Kim; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018 Nov.       Impact factor: 3.066

2.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

3.  Three-dimensional finite element analysis of a newly designed onplant miniplate anchorage system.

Authors:  Lin Liu; Yin-Ying Qu; Li-Jun Jiang; Qian Zhou; Tian-Qi Tang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2016-07-05

4.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

5.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

6.  Effects of monocortical and bicortical mini-implant anchorage on bone-borne palatal expansion using finite element analysis.

Authors:  Robert J Lee; Won Moon; Christine Hong
Journal:  Am J Orthod Dentofacial Orthop       Date:  2017-05       Impact factor: 2.650

7.  A CBCT atlas of buccal cortical bone thickness in interradicular spaces.

Authors:  Patrick B Holmes; Bethany J Wolf; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

8.  Investigation of bone conditions for orthodontic anchorage plates in the anterior mandible.

Authors:  Thomas Michael Präger; Hans Georg Brochhagen; Axel Mußler; Robert Mischkowski; Paul-Georg Jost-Brinkmann; Ralf Müller-Hartwich
Journal:  J Orofac Orthop       Date:  2013-08-25       Impact factor: 1.938

9.  An evaluation of insertion sites for mini-implants: a micro - CT study of human autopsy material.

Authors:  Morten G Laursen; Birte Melsen; Paolo M Cattaneo
Journal:  Angle Orthod       Date:  2012-08-27       Impact factor: 2.079

10.  Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study.

Authors:  Ramzi Duaibis; Budi Kusnoto; Raghu Natarajan; Linping Zhao; Carla Evans
Journal:  Angle Orthod       Date:  2012-03-05       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.