[Clinical and experimental results with a new fully automatic self-tonometer].

J Draeger1, R Schwartz, C Deutsch, S Groenhoff.   

Abstract

In a clinical study 25 patients being treated at the Department of Ophthalmology in the Hamburg University were instructed in self-tonometry using a new automatic tonometer. In a first sequence, three self-measurements were taken by the patients within 1 min; then a control measurement with a motor-driven hand applanation tonometer (HAT) was taken by a physician. The procedure was repeated 6-10 min afterwards without new local anesthesia. In addition, a dynamometer was applied to 5 healthy eyes in order to test the self-tonometer at higher pressure levels. The correlation of repetitive measurements of the self-tonometer showed good results for the patient measurements (r1 = 0.97, SD1 = 1.66 mmHg, r2 = 0.96, SD2 = 1.47 mmHg) and slightly worse values for the measurements with the dynamometer (r3 = 0.97, SD3 = 2.02 mmHg), probably due to the non-physiological deformation of the eye induced by the dynamometer. To establish accuracy, the results were compared to the HAT. The following results were achieved: (r1 = 0.97, s1 = 1.71 mmHg, r2 = 0.96, s2 = 1.49 mmHg, r3 = 0.97, s3 = 2.69 mmHg). Other studies with the self-tonometer will follow in order to optimize its accuracy and design. Self-tonometry under conditions of microgravity is planned for the 2nd German Spacelab Mission and the Russian Space station MIR. In the future, self-tonometry will play an important part in the management of glaucoma.

Entities:  

Mesh:

Year:  1991        PMID: 1889784

Source DB:  PubMed          Journal:  Fortschr Ophthalmol        ISSN: 0723-8045


  6 in total

Review 1.  [Technical options and prospects for telemedical devices in ophthalmology].

Authors:  R Grossjohann; C Jürgens; F Tost
Journal:  Ophthalmologe       Date:  2009-09       Impact factor: 1.059

2.  [Evaluation of the self-tonometer Icare ONE in comparison to Goldmann applanation tonometry].

Authors:  V Witte; Ä Glass; R Beck; R Guthoff
Journal:  Ophthalmologe       Date:  2012-10       Impact factor: 1.059

3.  Self-tonometry under microgravity conditions.

Authors:  J Draeger; R Schwartz; S Groenhoff; C Stern
Journal:  Clin Investig       Date:  1993-09

4.  A new rebound tonometer for home monitoring of intraocular pressure.

Authors:  André Rosentreter; Kerstin S Jablonski; Anne C Mellein; Stergiani Gaki; Arno Hueber; Thomas S Dietlein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-14       Impact factor: 3.117

5.  [Telematic-assisted self-tonometry (TAS)].

Authors:  R Lämmer; M E M Groh; G Michelson
Journal:  Ophthalmologe       Date:  2004-08       Impact factor: 1.059

6.  Self-tonometry: technical aspects of calibration and clinical application.

Authors:  S Groenhoff; J Draeger; C Deutsch; R Wiezorrek; B Hock
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.