Literature DB >> 1428562

Self-tonometry: technical aspects of calibration and clinical application.

S Groenhoff1, J Draeger, C Deutsch, R Wiezorrek, B Hock.   

Abstract

Self-tonometry could be established as an important diagnostic tool in the early diagnosis and follow-up of glaucoma provided that a self-tonometer is precise, safe and easy to use. Furthermore, it has to comply with the legal standards for tonometer calibration. A new software-controlled detection system for the self-tonometer permits the evaluation of external factors during the measurement which influence the precision of the tonometric readings. The updated version of the self-tonometer (ST) was compared to the Draeger hand-held applanation tonometer (HAT) in a clinical study with 82 patients (151 eyes). The results show a regression line characterized by a slope of 0.99, an y interception of 1.41, a correlation coefficient of 0.96 and a standard deviation for the ST readings of +/- 1.78 mmHg. Self-tonometry improves the IOP monitoring as well as patient compliance and therefore is a potential diagnostic tool in the management of glaucoma.

Entities:  

Mesh:

Year:  1992        PMID: 1428562     DOI: 10.1007/bf00917980

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  17 in total

1.  The intraocular pressure: clinical aspects.

Authors:  W Leydhecker
Journal:  Ann Ophthalmol       Date:  1976-04

2.  The phasic variations in the ocular tension in primary glaucoma.

Authors:  S DUKE-ELDER
Journal:  Am J Ophthalmol       Date:  1952-01       Impact factor: 5.258

3.  [Progress in early detection and follow up of glaucoma].

Authors:  J Draeger
Journal:  Klin Monbl Augenheilkd       Date:  1989-11       Impact factor: 0.700

4.  Self-measurement of blood pressure. World Hypertension League.

Authors: 
Journal:  Bull World Health Organ       Date:  1988       Impact factor: 9.408

5.  [Optimizing the automatic self-tonometer by an acoustic control signal and changed fixation optics].

Authors:  J Draeger; S Groenhoff; B Hock; M Klemm
Journal:  Ophthalmologe       Date:  1993-02       Impact factor: 1.059

6.  An instrument for self-measurement of intraocular pressure.

Authors:  R C Zeimer; J T Wilensky
Journal:  IEEE Trans Biomed Eng       Date:  1982-03       Impact factor: 4.538

7.  [Tonometer calibration (author's transl)].

Authors:  E Weigelin; K Jessen
Journal:  Klin Monbl Augenheilkd       Date:  1981-07       Impact factor: 0.700

8.  [On a position-independent applanation tonometer].

Authors:  J Draeger
Journal:  Klin Monbl Augenheilkd       Date:  1966       Impact factor: 0.700

9.  [Self-tonometry--technical possibilities and clinical significance].

Authors:  J Draeger; S Groenhoff
Journal:  Fortschr Ophthalmol       Date:  1990

10.  [Clinical and experimental results with a new fully automatic self-tonometer].

Authors:  J Draeger; R Schwartz; C Deutsch; S Groenhoff
Journal:  Fortschr Ophthalmol       Date:  1991
View more
  2 in total

1.  Self-tonometry under microgravity conditions.

Authors:  J Draeger; R Schwartz; S Groenhoff; C Stern
Journal:  Clin Investig       Date:  1993-09

2.  Glaucoma screening.

Authors:  R A Hitchings
Journal:  Br J Ophthalmol       Date:  1993-06       Impact factor: 4.638

  2 in total