Literature DB >> 18848654

Human cancellous bone from T12-L1 vertebrae has unique microstructural and trabecular shear stress properties.

Yener N Yeni1, Do-Gyoon Kim, George W Divine, Evan M Johnson, Dianna D Cody.   

Abstract

Increase of trabecular stress variability with loss of bone mass has been implicated as a mechanism for increased cancellous bone fragility with age and disease. In the current study, a previous observation that trabecular shear stress estimates vary along the human spine such that the cancellous tissue from the thoracic 12 (T12)-lumbar 1 (L1) junction experiences the highest trabecular stresses for a given load was tested as a formal hypothesis using multiple human spines. Thoracic 4, T5, T7, T9, T10, T12, L1, L2, L4 and L5 vertebrae from 10 human cadaver spines were examined. One specimen in the central anterior region was cored in the supero-inferior (SI) direction and another in the postero-lateral region was cored in the transverse (TR) direction from each vertebra. Micro-CT-based large-scale finite element models were constructed for each specimen and compression in the long axis of the cylindrical specimens was simulated. Cancellous bone modulus and the mean, the standard deviation, variability and amplification of trabecular von Mises stresses were computed. Bone volume fraction, trabecular number, trabecular thickness, trabecular separation, connectivity density and degree of anisotropy were calculated using 3D stereology. The results were analyzed using a mixed model in which spine level was modeled using a quadratic polynomial. The maximum of trabecular shear stress amplification and minimum of bone volume fraction were found in the cancellous tissue from the T12-L1 location when results from the samples of the same vertebra were averaged. When groups were separated, microstructure and trabecular stresses varied with spine level, extrema being at the T12-L1 levels, for the TR specimens only. SI/TR ratio of measured parameters also had quadratic relationships with spine level, the extrema being located at T12-L1 levels for most parameters. For microstructural parameters, these ratios approached to a value of one at the T12-L1 level, suggesting that T12-L1 vertebrae have more uniform cancellous tissue properties than other levels. The mean intercept length in the secondary principal direction of trabecular orientation could account for the variation of all mechanical parameters with spine level. Our results support that cancellous tissue from T12-L1 levels is unique and may explain, in part, the higher incidence of vertebral fractures at these levels.

Entities:  

Mesh:

Year:  2008        PMID: 18848654      PMCID: PMC2667817          DOI: 10.1016/j.bone.2008.09.002

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  56 in total

1.  Accuracy of cancellous bone volume fraction measured by micro-CT scanning.

Authors:  M Ding; A Odgaard; I Hvid
Journal:  J Biomech       Date:  1999-03       Impact factor: 2.712

2.  Asymptomatic fractures in osteoporotic spines of the aged.

Authors:  J GERSHON-COHEN; A M RECHTMAN; H SCHRAER; N BLUMBERG
Journal:  J Am Med Assoc       Date:  1953-10-17

3.  Multiple identical stress fractures in monozygotic twins. Case report.

Authors:  A Singer; O Ben-Yehuda; Z Ben-Ezra; S Zaltzman
Journal:  J Bone Joint Surg Am       Date:  1990-03       Impact factor: 5.284

Review 4.  Clinical consequences of vertebral fractures.

Authors:  P D Ross
Journal:  Am J Med       Date:  1997-08-18       Impact factor: 4.965

5.  Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025.

Authors:  Russel Burge; Bess Dawson-Hughes; Daniel H Solomon; John B Wong; Alison King; Anna Tosteson
Journal:  J Bone Miner Res       Date:  2007-03       Impact factor: 6.741

6.  Intervertebral variation in trabecular microarchitecture throughout the normal spine in relation to age.

Authors:  H J Grote; M Amling; M Vogel; M Hahn; M Pösl; G Delling
Journal:  Bone       Date:  1995-03       Impact factor: 4.398

7.  Collapsed vertebrae: a review of 659 autopsies.

Authors:  V L Fornasier; A A Czitrom
Journal:  Clin Orthop Relat Res       Date:  1978 Mar-Apr       Impact factor: 4.176

8.  Human lumbar vertebrae. Quantitative three-dimensional anatomy.

Authors:  M M Panjabi; V Goel; T Oxland; K Takata; J Duranceau; M Krag; M Price
Journal:  Spine (Phila Pa 1976)       Date:  1992-03       Impact factor: 3.468

9.  Incidental vertebral fractures discovered with chest radiography in the emergency department: prevalence, recognition, and osteoporosis management in a cohort of elderly patients.

Authors:  Sumit R Majumdar; Nancy Kim; Ian Colman; Anthony M Chahal; Gregory Raymond; Ho Jen; Kerry G Siminoski; David A Hanley; Brian H Rowe
Journal:  Arch Intern Med       Date:  2005-04-25

10.  Beyond hip: importance of other nonspinal fractures.

Authors:  P D Delmas; F Marin; R Marcus; D A Misurski; B H Mitlak
Journal:  Am J Med       Date:  2007-05       Impact factor: 4.965

View more
  6 in total

1.  Mechanical loading causes detectable changes in morphometric measures of trabecular structure in human cancellous bone.

Authors:  Yener N Yeni; Brenda Wu; Lily Huang; Daniel Oravec
Journal:  J Biomech Eng       Date:  2013-05       Impact factor: 2.097

2.  Variability of trabecular microstructure is age-, gender-, race- and anatomic site-dependent and affects stiffness and stress distribution properties of human vertebral cancellous bone.

Authors:  Yener N Yeni; Matthew J Zinno; Janardhan S Yerramshetty; Roger Zauel; David P Fyhrie
Journal:  Bone       Date:  2011-07-19       Impact factor: 4.398

3.  Stiffness of the endplate boundary layer and endplate surface topography are associated with brittleness of human whole vertebral bodies.

Authors:  Srikant Nekkanty; Janardhan Yerramshetty; Do-Gyoon Kim; Roger Zauel; Evan Johnson; Dianna D Cody; Yener N Yeni
Journal:  Bone       Date:  2010-07-12       Impact factor: 4.398

4.  Increased microstructural variability is associated with decreased structural strength but with increased measures of structural ductility in human vertebrae.

Authors:  Janardhan Yerramshetty; Do-Gyoon Kim; Yener N Yeni
Journal:  J Biomech Eng       Date:  2009-09       Impact factor: 2.097

5.  Photoelastic analisys in the lower region of vertebral body L4.

Authors:  Sarah Fakher Fakhouri; Ariane Zamarioli; Marcos Massao Shimano; Helton Luiz Aparecido Defino; Cleudmar Amaral Araujo; Antonio Carlos Shimano
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

6.  Cancellous bone properties and matrix content of TGF-beta2 and IGF-I in human tibia: a pilot study.

Authors:  Yener N Yeni; X Neil Dong; Bingbing Zhang; Gary J Gibson; David P Fyhrie
Journal:  Clin Orthop Relat Res       Date:  2009-05-27       Impact factor: 4.176

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.