Accuracy of cancellous bone volume fraction measured by micro-CT scanning.

M Ding1, A Odgaard, I Hvid.   

Abstract

Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner supplied algorithm (method I). A significant deviation of volume fraction from method I was found: both the y-intercept and the slope of the regression line were significantly different from those of the Archimedes-based volume fraction (p < 0.001). New individual thresholds were determined based on a calibration of volume fraction to the Archimedes-based volume fractions (method II). The mean thresholds of the two methods were applied to segment 20 randomly selected specimens. The results showed that volume fraction using the mean threshold of method I was underestimated by 4% (p = 0.001), whereas the mean threshold of method II yielded accurate values. The precision of the measurement was excellent. Our data show that care must be taken when applying thresholds in generating 3-D data, and that a fixed threshold may be used to obtain reliable volume fraction data. This fixed threshold may be determined from the Archimedes-based volume fraction of a subgroup of specimens. The threshold may vary between different materials, and so it should be determined whenever a study series is performed.

Entities:  

Mesh:

Year:  1999        PMID: 10093033     DOI: 10.1016/s0021-9290(98)00176-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  39 in total

1.  Effects of a perfusion bioreactor activated novel bone substitute in spine fusion in sheep.

Authors:  Jesper Roed Sørensen; Kariatta Ester Koroma; Ming Ding; David Wendt; Stig Jespersen; Maria Vinther Juhl; Naseem Theilgaard; Ivan Martin; Søren Overgaard
Journal:  Eur Spine J       Date:  2012-07-10       Impact factor: 3.134

2.  Total and intercondylar notch bone resection in posterior stabilized knee arthroplasty: analysis of five manufacturer designs.

Authors:  Murat Bozkurt; Mesut Tahta; Safa Gursoy; Mustafa Akkaya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-14       Impact factor: 4.342

3.  Study of subchondral bone adaptations in a rodent surgical model of OA using in vivo micro-computed tomography.

Authors:  D D McErlain; C T G Appleton; R B Litchfield; V Pitelka; J L Henry; S M Bernier; F Beier; D W Holdsworth
Journal:  Osteoarthritis Cartilage       Date:  2007-09-27       Impact factor: 6.576

4.  Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: comparison with synchrotron radiation microcomputed tomography and ash measurements.

Authors:  G J Kazakia; A J Burghardt; S Cheung; S Majumdar
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

5.  Anticipating bipedalism: trabecular organization in the newborn ilium.

Authors:  Craig A Cunningham; Sue M Black
Journal:  J Anat       Date:  2009-06       Impact factor: 2.610

6.  Effect of intraspecimen spatial variation in tissue mineral density on the apparent stiffness of trabecular bone.

Authors:  Narges Kaynia; Elaine Soohoo; Tony M Keaveny; Galateia J Kazakia
Journal:  J Biomech Eng       Date:  2015-01       Impact factor: 2.097

7.  Technical note: early post-mortem changes of human bone in taphonomy with μCT.

Authors:  Erwan Le Garff; Vadim Mesli; Yann Delannoy; Thomas Colard; Xavier Demondion; Anne Becart; Valéry Hedouin
Journal:  Int J Legal Med       Date:  2016-12-29       Impact factor: 2.686

8.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

9.  Use of carboxymethyl cellulose and collagen carrier with equine bone lyophilisate suggests late onset bone regenerative effect in a humerus drill defect - a pilot study in six sheep.

Authors:  Jonas Jensen; Casper Bindzus Foldager; Thomas Vestergaard Jakobsen; Kjeld Søballe; Cody Bünger; Jorgen Baas
Journal:  Open Orthop J       Date:  2010-05-11

10.  Stiffness and strength of bone in osteoporotic patients treated with varying durations of oral bisphosphonates.

Authors:  J Ward; C Wood; K Rouch; D Pienkowski; H H Malluche
Journal:  Osteoporos Int       Date:  2016-07-22       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.