Literature DB >> 18838269

Motor adaptation during dorsiflexion-assisted walking with a powered orthosis.

Pei-Chun Kao1, Daniel P Ferris.   

Abstract

A robotic ankle-foot orthosis (AFO) that provides powered assistance could adjust to varying gait dynamics much better than a rigid AFO. To provide insight into how humans would adapt to a powered AFO, we studied the response of neurologically intact subjects walking with an active dorsiflexion assist orthosis proportionally controlled by tibialis anterior electromyography (EMG). We examined the two mechanical functions of ankle dorsiflexors in gait (power absorption at heel strike and power generation at toe-off) by recruiting two groups of healthy subjects: Group One, called Continuous Control (n=5), had dorsiflexion assistance both at the initial heel contact and during swing; Group Two, called Swing Control (n=5), had the assistance only during swing. We hypothesized both groups of subjects would reduce tibialis anterior EMG amplitude with practice walking with the powered dorsiflexion assist. Ten healthy subjects were fitted with custom-made orthoses that included an artificial pneumatic muscle providing dorsiflexor torque. We collected lower body kinematics, EMG, and artificial muscle force while subjects walked on a treadmill for two 30-min training sessions. We found that subjects walked with increased ankle dorsiflexion by 9 degrees but showed different adaptation responses of the two tibialis anterior EMG bursts. The first EMG burst around heel strike had approximately 28% lower amplitudes (p<0.05) but the second EMG burst during swing had similar amplitudes. These results provide baseline data of EMG controlled dorsiflexion assist in neurologically intact humans that can be used to guide future studies on neurologically impaired individuals.

Entities:  

Mesh:

Year:  2008        PMID: 18838269      PMCID: PMC2663810          DOI: 10.1016/j.gaitpost.2008.08.014

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  21 in total

1.  Ankle plantar flexor force production is an important determinant of the preferred walk-to-run transition speed.

Authors:  Richard R Neptune; Kotaro Sasaki
Journal:  J Exp Biol       Date:  2005-03       Impact factor: 3.312

Review 2.  Energetic consequences of walking like an inverted pendulum: step-to-step transitions.

Authors:  Arthur D Kuo; J Maxwell Donelan; Andy Ruina
Journal:  Exerc Sport Sci Rev       Date:  2005-04       Impact factor: 6.230

3.  Powered lower limb orthoses for gait rehabilitation.

Authors:  Daniel P Ferris; Gregory S Sawicki; Antoinette Domingo
Journal:  Top Spinal Cord Inj Rehabil       Date:  2005

4.  Custom-designed haptic training for restoring reaching ability to individuals with poststroke hemiparesis.

Authors:  James L Patton; Mark Kovic; Ferdinando A Mussa-Ivaldi
Journal:  J Rehabil Res Dev       Date:  2006 Aug-Sep

5.  Robot-enhanced motor learning: accelerating internal model formation during locomotion by transient dynamic amplification.

Authors:  Jeremy L Emken; David J Reinkensmeyer
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2005-03       Impact factor: 3.802

6.  The role of ankle plantar flexor muscle work during walking.

Authors:  M Meinders; A Gitter; J M Czerniecki
Journal:  Scand J Rehabil Med       Date:  1998-03

7.  Mechanics and energetics of level walking with powered ankle exoskeletons.

Authors:  Gregory S Sawicki; Daniel P Ferris
Journal:  J Exp Biol       Date:  2008-05       Impact factor: 3.312

8.  Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait.

Authors:  Joaquin A Blaya; Hugh Herr
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2004-03       Impact factor: 3.802

9.  Mechanical work for step-to-step transitions is a major determinant of the metabolic cost of human walking.

Authors:  J Maxwell Donelan; Rodger Kram; Arthur D Kuo
Journal:  J Exp Biol       Date:  2002-12       Impact factor: 3.312

10.  Interacting adaptive processes with different timescales underlie short-term motor learning.

Authors:  Maurice A Smith; Ali Ghazizadeh; Reza Shadmehr
Journal:  PLoS Biol       Date:  2006-05-23       Impact factor: 8.029

View more
  20 in total

1.  Muscle recruitment and coordination with an ankle exoskeleton.

Authors:  Katherine M Steele; Rachel W Jackson; Benjamin R Shuman; Steven H Collins
Journal:  J Biomech       Date:  2017-05-18       Impact factor: 2.712

2.  Invariant hip moment pattern while walking with a robotic hip exoskeleton.

Authors:  Cara L Lewis; Daniel P Ferris
Journal:  J Biomech       Date:  2011-02-18       Impact factor: 2.712

3.  Robotic lower limb exoskeletons using proportional myoelectric control.

Authors:  Daniel P Ferris; Cara L Lewis
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

4.  Transtibial amputee joint motion has increased attractor divergence during walking compared to non-amputee gait.

Authors:  Shane R Wurdeman; Sara A Myers; Nicholas Stergiou
Journal:  Ann Biomed Eng       Date:  2012-11-22       Impact factor: 3.934

5.  Automatic identification of gait events using an instrumented sock.

Authors:  Stephen J Preece; Laurence P J Kenney; Matthew J Major; Tilak Dias; Edward Lay; Bosco T Fernandes
Journal:  J Neuroeng Rehabil       Date:  2011-05-27       Impact factor: 4.262

6.  Sensing pressure distribution on a lower-limb exoskeleton physical human-machine interface.

Authors:  Stefano Marco Maria De Rossi; Nicola Vitiello; Tommaso Lenzi; Renaud Ronsse; Bram Koopman; Alessandro Persichetti; Fabrizio Vecchi; Auke Jan Ijspeert; Herman van der Kooij; Maria Chiara Carrozza
Journal:  Sensors (Basel)       Date:  2010-12-28       Impact factor: 3.576

7.  Effect of pneumatic compressing powered orthosis in stroke patients: preliminary study.

Authors:  Eun Sil Kim; Yong-Soon Yoon; Min Kyun Sohn; Soo-Hyun Kwak; Jong Ho Choi; Ji Sun Oh
Journal:  Ann Rehabil Med       Date:  2015-04-24

8.  A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition.

Authors:  Gregory S Sawicki; Daniel P Ferris
Journal:  J Neuroeng Rehabil       Date:  2009-06-23       Impact factor: 4.262

9.  Muscle activation patterns during walking from transtibial amputees recorded within the residual limb-prosthetic interface.

Authors:  Stephanie Huang; Daniel P Ferris
Journal:  J Neuroeng Rehabil       Date:  2012-08-10       Impact factor: 4.262

10.  A flexible sensor technology for the distributed measurement of interaction pressure.

Authors:  Marco Donati; Nicola Vitiello; Stefano Marco Maria De Rossi; Tommaso Lenzi; Simona Crea; Alessandro Persichetti; Francesco Giovacchini; Bram Koopman; Janez Podobnik; Marko Munih; Maria Chiara Carrozza
Journal:  Sensors (Basel)       Date:  2013-01-15       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.