Literature DB >> 18827239

The NexGen LPS-flex to the knee prosthesis at a minimum of three years.

T-H Kim1, D-H Lee, S-I Bin.   

Abstract

We carried out a prospective study to assess the clinical outcome, complications and survival of the NexGen Legacy posterior-stabilised-Flex total knee replacement (TKR) in a consecutive series of 278 knees between May 2003 and February 2005. Mean follow-up for 259 TKRs (98.2%) was 3.8 years (3.0 to 4.8). Annual follow-up showed improvement in the Knee Society scores (paired t-test, p < 0.05). At the last follow-up, the mean maximum flexion was 135 degrees (110 degrees to 150 degrees). Two knees showed radiolucent lines, but revision was not required because the patients were asymptomatic. Revision was required in one case because of infection, but there were no prosthesis-related revisions. There were no other complications. The estimated survival rate at four years with revision for any reason and prosthesis-related problems was 99.6% and 100%, respectively. This relatively large study indicates that the legacy posterior stabilised-Flex design provides excellent short-term outcome but warrants ongoing evaluation to confirm the long-term durability and functioning of the implant.

Entities:  

Mesh:

Year:  2008        PMID: 18827239     DOI: 10.1302/0301-620X.90B10.21050

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  23 in total

1.  A new high-flexion knee scoring system to eliminate the ceiling effect.

Authors:  Sang-Eun Na; Chul-Won Ha; Choong-Hee Lee
Journal:  Clin Orthop Relat Res       Date:  2011-11-29       Impact factor: 4.176

2.  Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?

Authors:  Sung-Do Cho; Yoon-Seok Youm; Ki-Bong Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-29       Impact factor: 4.342

3.  High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-up.

Authors:  Aree Tanavalee; Srihatach Ngarmukos; Saran Tantavisut; Arak Limtrakul
Journal:  Int Orthop       Date:  2010-10-24       Impact factor: 3.075

4.  Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA.

Authors:  Byung June Chung; Yeon Gwi Kang; Chong Bum Chang; Sung Ju Kim; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

5.  In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty.

Authors:  Angela L Moynihan; Kartik M Varadarajan; George R Hanson; Sang-Eun Park; Kyung Wook Nha; Jeremy F Suggs; Todd Johnson; Guoan Li
Journal:  Int Orthop       Date:  2009-04-22       Impact factor: 3.075

Review 6.  Patellar denervation with electrocautery in total knee arthroplasty without patellar resurfacing: a meta-analysis.

Authors:  Tao Cheng; Chen Zhu; Yongyuan Guo; Sifeng Shi; Desheng Chen; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-07       Impact factor: 4.342

7.  Brief followup report: Does high-flexion total knee arthroplasty allow deep flexion safely in Asian patients?

Authors:  Hyuk-Soo Han; Seung-Baik Kang
Journal:  Clin Orthop Relat Res       Date:  2013-05       Impact factor: 4.176

8.  Active Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion.

Authors:  Young Dong Song; Nimash Jain; Yeon Gwi Kang; Tae Yune Kim; Tae Kyun Kim
Journal:  Knee Surg Relat Res       Date:  2016-06-01

9.  Modular tibial plate for minimally invasive total knee arthroplasty.

Authors:  Francesco Benazzo; Stefano Marco Paolo Rossi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-24       Impact factor: 4.342

10.  Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA.

Authors:  Tae Kyun Kim; Chong Bum Chang; Yeon Gwi Kang; Byung June Chung; Hyung Joon Cho; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-28       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.