Literature DB >> 22125252

A new high-flexion knee scoring system to eliminate the ceiling effect.

Sang-Eun Na1, Chul-Won Ha, Choong-Hee Lee.   

Abstract

BACKGROUND: Various scoring systems document improvement after TKA, but most are associated with a ceiling effect that may fail to distinguish between patients having different levels of knee function after TKA. We therefore developed a new scoring system for patients with higher levels of flexion to eliminate ceiling effects observed with current systems. QUESTIONS/PURPOSES: The purposes of this study were (1) to determine whether the high-flexion knee score eliminates the ceiling effect, (2) to assess the validity and responsiveness of the high-flexion knee score, and (3) to determine whether the high-flexion knee score can aid in differentiation of the knee status of patients at the ceiling level.
METHODS: We prospectively studied 165 patients with 201 well-functioning knees who had undergone primary TKA. We obtained Knee Society scores, WOMAC scores, Feller scores, SF-36 scores, and high-flexion knee scores for all patients. The high-flexion knee score includes items that reflect knee function in the high functional range, such as sitting on or rising from the floor, squatting, or kneeling. We determined the ceiling effects and score distributions of various scoring systems. We performed a convergent validity test of the high-flexion knee score by correlation analysis with these various scoring systems. Responsiveness of the high-flexion knee score was assessed by correlation analysis of changes in various scoring systems. To determine whether the high-flexion knee score can aid in differentiation of knee status of patients at the ceiling level, relative responsiveness of the various scores in the ceiling versus below the ceiling range was determined.
RESULTS: The high-flexion knee score showed no ceiling effect, whereas the other systems did. Addition of the high-flexion knee score to the other scoring systems eliminated these ceiling effects and resulted in more normalized score distributions. The high-flexion knee score correlated (r = -0.77) with WOMAC in postoperative scores, and it also correlated with the changes in WOMAC (r = -0.69) and SF-36 physical functioning (r = 0.62). The correlation of WOMAC score with SF-36 physical function score was lower in patients at the ceiling level of the Knee Society knee score and Knee Society function score, compared with the correlation at below-ceiling range, whereas the high-flexion knee score maintained a correlation with the SF-36 physical function score, even at the ceiling level of the Knee Society knee score and Knee Society function score.
CONCLUSIONS: Compared with other systems, the high-function knee score appears valid for evaluating the knee status in the high-flexion range. Our data suggest the high-flexion knee score differentiates among the knee status in the high-function range. Furthermore, the high-function knee score eliminates the ceiling effect of the currently used scoring tools, and thus may be useful when combined with other scoring systems. LEVEL OF EVIDENCE: Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2011        PMID: 22125252      PMCID: PMC3254737          DOI: 10.1007/s11999-011-2203-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  29 in total

Review 1.  Methods for assessing responsiveness: a critical review and recommendations.

Authors:  J A Husted; R J Cook; V T Farewell; D D Gladman
Journal:  J Clin Epidemiol       Date:  2000-05       Impact factor: 6.437

2.  Rationale of the Knee Society clinical rating system.

Authors:  J N Insall; L D Dorr; R D Scott; W N Scott
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

3.  Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee.

Authors:  N Bellamy; W W Buchanan; C H Goldsmith; J Campbell; L W Stitt
Journal:  J Rheumatol       Date:  1988-12       Impact factor: 4.666

4.  Rating systems in the evaluation of knee ligament injuries.

Authors:  Y Tegner; J Lysholm
Journal:  Clin Orthop Relat Res       Date:  1985-09       Impact factor: 4.176

5.  Total knee arthroplasty with the kinematic prosthesis. Results after five to nine years: a follow-up note.

Authors:  J Wright; F C Ewald; P S Walker; W H Thomas; R Poss; C B Sledge
Journal:  J Bone Joint Surg Am       Date:  1990-08       Impact factor: 5.284

6.  Responsiveness and sensitivity to change of SLE disease activity measures.

Authors:  M Corzillius; P Fortin; G Stucki
Journal:  Lupus       Date:  1999       Impact factor: 2.911

7.  Long-term results of total joint arthroplasty in elderly patients who are frail.

Authors:  Asit K Shah; James Celestin; Michael L Parks; Roger N Levy
Journal:  Clin Orthop Relat Res       Date:  2004-08       Impact factor: 4.176

Review 8.  Health-related quality of life in total hip and total knee arthroplasty. A qualitative and systematic review of the literature.

Authors:  Olivier Ethgen; Olivier Bruyère; Florent Richy; Charles Dardennes; Jean-Yves Reginster
Journal:  J Bone Joint Surg Am       Date:  2004-05       Impact factor: 5.284

9.  The MOS 36-Item Short-Form Health Survey (SF-36): II. Psychometric and clinical tests of validity in measuring physical and mental health constructs.

Authors:  C A McHorney; J E Ware; A E Raczek
Journal:  Med Care       Date:  1993-03       Impact factor: 2.983

10.  Relative responsiveness of condition-specific and generic health status measures in degenerative lumbar spinal stenosis.

Authors:  G Stucki; M H Liang; A H Fossel; J N Katz
Journal:  J Clin Epidemiol       Date:  1995-11       Impact factor: 6.437

View more
  28 in total

1.  An intraoperative load sensor did not improve the early postoperative results of posterior-stabilized TKA for osteoarthritis with varus deformities.

Authors:  Sang Jun Song; Se Gu Kang; Yeon Je Lee; Kang Il Kim; Cheol Hee Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-12-03       Impact factor: 4.342

Review 2.  Larger range of motion and increased return to activity, but higher revision rates following unicompartmental versus total knee arthroplasty in patients under 65: a systematic review.

Authors:  Laura J Kleeblad; Jelle P van der List; Hendrik A Zuiderbaan; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-28       Impact factor: 4.342

3.  [Total knee arthroplasty in 2014 : Results, expectations, and complications].

Authors:  G Matziolis; E Röhner
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

4.  Midterm clinical and radiographic results of the medial pivot total knee system.

Authors:  Robert Schmidt; Steven Ogden; J David Blaha; Angelia Alexander; David A Fitch; C Lowry Barnes
Journal:  Int Orthop       Date:  2014-07-11       Impact factor: 3.075

5.  Higher physical activity and lower pain levels before surgery predict non-improvement of knee pain 1 year after TKA.

Authors:  Nikolai Kornilov; Maren Falch Lindberg; Caryl Gay; Alexander Saraev; Taras Kuliaba; Leiv Arne Rosseland; Anners Lerdal
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-15       Impact factor: 4.342

6.  Translation and Validation of Forgotten Joint Score for Total Hip Arthroplasty for Indian Population.

Authors:  Siddharth S Sethy; Tarun Goyal; Souvik Paul; S Lakshmana Das; Arghya Kundu Choudhury; Roop Bhushan Kalia
Journal:  Indian J Orthop       Date:  2020-08-17       Impact factor: 1.251

7.  [Comparison of the effectiveness of unicompartmental arthroplasty and total knee arthroplasty based on patient scale data].

Authors:  Xiangyu Zu; Jun Wang; Ming Lu; Zongsheng Yin
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-12-15

Review 8.  Medial Pivot Versus Posterior-Stabilized Prosthesis Design in Primary Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Zihang Xu; Shengyuan Tian; Xiang Zhou; Ya Wei; Changbing Wu; Xianghua Jia; Hong Wang
Journal:  Indian J Orthop       Date:  2022-07-11       Impact factor: 1.033

9.  Kinematic femoral alignment with gap balancing and patient-specific instrumentation in total knee arthroplasty: a randomized clinical trial.

Authors:  Hagen Hommel; Matthew P Abdel; Carsten Perka
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-06

Review 10.  Unicondylar knee replacement versus total knee replacement for the treatment of medial knee osteoarthritis: a systematic review and meta-analysis.

Authors:  Meichao Deng; Yang Hu; Zhongzu Zhang; Hongjun Zhang; Yiming Qu; Gaohai Shao
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-29       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.