Alyse Fm Cameron1, Keith Rome, Wayne A Hing.
Abstract
BACKGROUND: The Abductor hallucis muscle (AbdH) plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults.Entities:
Year: 2008 PMID: 18822116 PMCID: PMC2565658 DOI: 10.1186/1757-1146-1-12
Source DB: PubMed Journal: J Foot Ankle Res ISSN: 1757-1146 Impact factor: 2.303
Figure 1Ultrasound image of abductor hallucis muscle.
Figure 2Abductor hallucis muscle with dorso-plantar thickness and medio-lateral width points marked.
Figure 3Abductor hallucis muscle with cross-sectional area outlined.
Descriptive statistics of abductor hallucis muscle parameters.
| Parameter | Day | Mean ± SD | ICC (95% CI) |
| Dorso-Plantar Thickness (mm) | 1 | 11.55 ± 1.09 | 0.97 (0.98–0.99) |
| 2 | 11.52 ± 1.03 | 0.97 (0.98–0.99) | |
| Medio-lateral Width (mm) | 1 | 28.98 ± 2.69 | 0.97 (0.95–0.98) |
| 2 | 29.03 ± 2.54 | 0.97 (0.95–0.98) | |
| Cross-sectional Area (mm2) | 1 | 269.23 ± 35.47 | 0.98 (0.96–0.99) |
| 2 | 276.55 ± 33.98 | 0.95 (0.92–0.97) |
Intratester within session reliability ICC values.
| Parameter | Day | ICC (95% CI) |
| Dorso-Plantar Thickness (mm) | 1 | 0.97 (0.98–0.99) |
| 2 | 0.97 (0.98–0.99) | |
| Medio-lateral Width (mm) | 1 | 0.97 (0.95–0.98) |
| 2 | 0.97 (0.95–0.98) | |
| Cross-sectional Area (mm2) | 1 | 0.98 (0.96–0.99) |
| 2 | 0.95 (0.92–0.97) |
Intratester between-session reliability ICC values.
| Parameter | ICC (95% CI) |
| Dorso-Plantar Thickness (mm) | 0.97 (0.95–0.98) |
| Medio-lateral Width (mm) | 0.94 (0.90–0.96) |
| Cross-sectional Area (mm2) | 0.79 (0.65–0.88) |
Figure 495% Limits of agreement for the measurement of abductor hallucis medio-lateral width (mm).
Figure 595% Limits of agreement for the measurement of dorso-planter thickness (mm).
Figure 695% Limits of agreement for the measurement of cross-sectional area (mm2).
Comparison of results gained from other ultrasound studies measuring muscle parameters.
| Study | Parameter | Results |
| Severinsen & Andersen (2007) 25 | Cross sectional area: extensor digitorum brevis | |
| Reeves et al (2004) 21 | Cross sectional area: vastus lateralis | ICC = 0.99 |
| Wallwork et al (2007) 29 | Width: L2–L3 Multifidus | ICC = 0.96 |
| Width: L4–L5 Multifidus | ICC = 0.97 |