Literature DB >> 18820306

Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: a literature review.

Gero S M Kinzinger1, Mert Eren, Peter R Diedrich.   

Abstract

Since the end of the 1970s, various appliances with intramaxillary anchorage for distalization of the upper molars have been described as an alternative to headgear. The major advantages of these innovative appliances are that they act permanently and are independent of patient compliance. The purpose of this study was to compare the efficiency, both quantitatively and qualitatively, of various appliance types with intramaxillary anchorage for non-compliance molar distalization. Eighty-five papers were reviewed, and 22 were identified as being suitable for inclusion. The selection was based on compliance with the following criteria: treatment group with at least 10 non-syndromal patients, conventional intraoral anchorage design using a palatal button and anchorage teeth, consistent cephalometric measurements in clinical-epidemiological studies, exact data on the course of treatment, and statistical presentation of the measured outcomes and their standard deviations. The results show that non-compliance molar distalization is possible with numerous different appliances. While molar distalization with standard pendulum appliances exhibited the largest values for dental-linear distalization, it also resulted in concurrent, substantial therapeutically undesirable distal tipping. However, specific modifications to the pendulum appliance allow achievement of almost bodily molar distalization. Different outcomes are quoted in the studies for the efficiency of loaded spring systems for distal molar movement, but it seems that the first class appliance and the palatal distal jet are more efficient than the vestibular Jones Jig. The studies identify anchorage loss as being found in the area of the incisors rather than the area of the first premolars. There was a trend for more substantial reciprocal side-effects to occur when only two teeth were included in the anchorage unit. Vertical components acting on the molars, premolars, and incisors, such as intrusion and extrusion, tended to be of secondary importance and, therefore, may be disregarded.

Entities:  

Mesh:

Year:  2008        PMID: 18820306     DOI: 10.1093/ejo/cjn047

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  17 in total

1.  Class II subdivision with skeletal transverse maxillary deficit treated by single-sitting bone-borne appliance.

Authors:  Luca Lombardo; Mario Palone; Giuliano Maino; Emanuele Paoletto; Antonella Carlucci; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2021-01-01       Impact factor: 2.079

2.  Effects of conventional anchorage on premolar root development during treatment with a pendulum appliance.

Authors:  Gero Kinzinger; Cora Pantel; Björn Ludwig; Norbert Gülden; Bettina Glasl; Jörg Lisson
Journal:  J Orofac Orthop       Date:  2010-07-30       Impact factor: 1.938

3.  Long-term stability of miniscrew anchored maxillary molar distalization in Class II treatment.

Authors:  Till Edward Bechtold; Young-Chel Park; Kyung-Ho Kim; Heekyu Jung; Ju-Young Kang; Yoon Jeong Choi
Journal:  Angle Orthod       Date:  2020-05-01       Impact factor: 2.079

4.  Upper molar distalization with skeletally anchored TopJet appliance.

Authors:  Bernhard C Pseiner; Anne Wunderlich; Josef W Freudenthaler
Journal:  J Orofac Orthop       Date:  2014-01-19       Impact factor: 1.938

5.  Maxillary molar distalization with miniscrew-supported appliances in Class II malocclusion: A systematic review.

Authors:  Roshan Noor Mohamed; Sakeenabi Basha; Yousef Al-Thomali
Journal:  Angle Orthod       Date:  2018-04-17       Impact factor: 2.079

6.  Evaluation of palatal bone density in adults and adolescents for application of skeletal anchorage devices.

Authors:  Seong Han; Mohamed Bayome; Jeongwon Lee; Yoon-Jin Lee; Hae-Hiang Song; Yoon-Ah Kook
Journal:  Angle Orthod       Date:  2011-11-11       Impact factor: 2.079

7.  Occlusal Plane Changes After Molar Distalization With a Pendulum Appliance in Growing Patients with Class II Malocclusion: A Retrospective Cephalometric Study.

Authors:  Marco Serafin; Rosamaria Fastuca; Elisabetta Castellani; Alberto Caprioglio
Journal:  Turk J Orthod       Date:  2021-02-23

8.  Fabrication and evaluation of a noncompliant molar distalizing appliance: bonded molar distalizer.

Authors:  A Sodagar; M S Ahmad Akhoundi; A Rafighii; S Arab
Journal:  J Dent (Tehran)       Date:  2011-09-30

9.  Evaluation of the palatal soft tissue thickness by cone-beam computed tomography.

Authors:  Trang Vu; Mohamed Bayome; Yoon-Ah Kook; Seong Ho Han
Journal:  Korean J Orthod       Date:  2012-12-28       Impact factor: 1.372

10.  Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches.

Authors:  Amirfarhang Miresmaeili; Ahmad Sajedi; Abbas Moghimbeigi; Nasrin Farhadian
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.