Evaluation of quantitative (90)Y SPECT based on experimental phantom studies.

D Minarik1, K Sjögreen Gleisner, M Ljungberg.   

Abstract

In SPECT imaging of pure beta emitters, such as (90)Y, the acquired spectrum is very complex, which increases the demands on the imaging protocol and the reconstruction. In this work, we have evaluated the quantitative accuracy of bremsstrahlung SPECT with focus on the reconstruction algorithm including model-based attenuation, scatter and collimator-detector response (CDR) compensations. The scatter and CDR compensation methods require pre-calculated point-spread functions, which were generated with the SIMIND MC program. The SIMIND program is dedicated for simulation of scintillation camera imaging and only handles photons. The aim of this work was therefore twofold. The first aim was to implement simulation of bremsstrahlung imaging into the SIMIND code and to validate simulations against experimental measurements. The second was to investigate the quality of bremsstrahlung SPECT imaging and to evaluate the possibility of quantifying the activity in differently shaped sources. In addition, a feasibility test was performed on a patient that underwent treatment with (90)Y-Ibritumomab tiuxetan (Zevalin). The MCNPX MC program was used to generate bremsstrahlung photon spectra which were used as source input in the SIMIND program. The obtained bremsstrahlung spectra were separately validated by experimental measurement using a HPGe detector. Validation of the SIMIND generated images was done by a comparison to gamma camera measurements of a syringe containing (90)Y. Results showed a slight deviation between simulations and measurements in image regions outside the source, but the agreement was sufficient for the purpose of generating scatter and CDR kernels. For the bremsstrahlung SPECT experiment, the RSD torso phantom with (90)Y in the liver insert was measured with and without background activities. Projection data were obtained using a GE VH/Hawkeye system. Image reconstruction was performed by using the OSEM algorithm with and without different combinations of model-based attenuation, scatter and CDR compensations. The reconstructed images were then evaluated in terms of the accuracy of the total activity estimate in the liver insert. It was found that the activity in a large source such as the liver was estimated with a bias of around -70%, when no compensations were included in the reconstruction, whereas when compensations were included the bias obtained was between -10 and 16%. It is concluded that although the (90)Y bremsstrahlung spectrum is continuous with no pronounced peak and the count rate is low, it is possible to achieve reasonably accurate activity estimates from bremsstrahlung SPECT images if proper compensations are applied in the reconstruction. This conclusion was also confirmed by the patient study.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18812648     DOI: 10.1088/0031-9155/53/20/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres.

Authors:  Renaud Lhommel; Larry van Elmbt; Pierre Goffette; Marc Van den Eynde; François Jamar; Stanislas Pauwels; Stephan Walrand
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-04-27       Impact factor: 9.236

2.  A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

Authors:  Xing Rong; Yong Du; Eric C Frey
Journal:  Phys Med Biol       Date:  2012-05-23       Impact factor: 3.609

3.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  A collimator optimization method for quantitative imaging: application to Y-90 bremsstrahlung SPECT.

Authors:  Xing Rong; Eric C Frey
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 5.  Dosimetry of yttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging?

Authors:  Stephan Walrand; Glenn D Flux; Mark W Konijnenberg; Roelf Valkema; Eric P Krenning; Renaud Lhommel; Stanislas Pauwels; Francois Jamar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-03-11       Impact factor: 9.236

6.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

Review 7.  The role of SPECT/CT in radioembolization of liver tumours.

Authors:  Hojjat Ahmadzadehfar; Heying Duan; Alexander R Haug; Stephan Walrand; Martha Hoffmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-01-18       Impact factor: 9.236

8.  Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

Authors:  Yuni K Dewaraja; Se Young Chun; Ravi N Srinivasa; Ravi K Kaza; Kyle C Cuneo; Bill S Majdalany; Paula M Novelli; Michael Ljungberg; Jeffrey A Fessler
Journal:  Med Phys       Date:  2017-10-28       Impact factor: 4.071

9.  Molecular optical imaging with radioactive probes.

Authors:  Hongguang Liu; Gang Ren; Zheng Miao; Xiaofen Zhang; Xiaodong Tang; Peizhen Han; Sanjiv S Gambhir; Zhen Cheng
Journal:  PLoS One       Date:  2010-03-01       Impact factor: 3.240

10.  Optimization of energy window for 90Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch.

Authors:  Xing Rong; Michael Ghaly; Eric C Frey
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.