Literature DB >> 18779063

Sparsity-enforced slice-selective MRI RF excitation pulse design.

Adam C Zelinski1, Lawrence L Wald, Kawin Setsompop, Vivek K Goyal, Elfar Adalsteinsson.   

Abstract

We introduce a novel algorithm for the design of fast slice-selective spatially-tailored magnetic resonance imaging (MRI) excitation pulses. This method, based on sparse approximation theory, uses a second-order cone optimization to place and modulate a small number of slice-selective sinc-like radio-frequency (RF) pulse segments ("spokes") in excitation k-space, enforcing sparsity on the number of spokes allowed while simultaneously encouraging those that remain to be placed and modulated in a way that best forms a user-defined in-plane target magnetization. Pulses are designed to mitigate B(1) inhomogeneity in a water phantom at 7 T and to produce highly-structured excitations in an oil phantom on an eight-channel parallel excitation system at 3 T. In each experiment, pulses generated by the sparsity-enforced method outperform those created via conventional Fourier-based techniques, e.g., when attempting to produce a uniform magnetization in the presence of severe B(1) inhomogeneity, a 5.7-ms 15-spoke pulse generated by the sparsity-enforced method produces an excitation with 1.28 times lower root mean square error than conventionally-designed 15-spoke pulses. To achieve this same level of uniformity, the conventional methods need to use 29-spoke pulses that are 7.8 ms long.

Entities:  

Mesh:

Year:  2008        PMID: 18779063      PMCID: PMC2666002          DOI: 10.1109/TMI.2008.920605

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  24 in total

1.  Central brightening due to constructive interference with, without, and despite dielectric resonance.

Authors:  Christopher M Collins; Wanzhan Liu; Weston Schreiber; Qing X Yang; Michael B Smith
Journal:  J Magn Reson Imaging       Date:  2005-02       Impact factor: 4.813

2.  B(1) destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil.

Authors:  Pierre-François Van de Moortele; Can Akgun; Gregor Adriany; Steen Moeller; Johannes Ritter; Christopher M Collins; Michael B Smith; J Thomas Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

3.  Measurement and correction of transmitter and receiver induced nonuniformities in vivo.

Authors:  Jinghua Wang; Maolin Qiu; Qing X Yang; Michael B Smith; R Todd Constable
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  Iterative RF pulse design for multidimensional, small-tip-angle selective excitation.

Authors:  Chun-yu Yip; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

5.  Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels.

Authors:  Peter Ullmann; Sven Junge; Markus Wick; Frank Seifert; Wolfgang Ruhm; Jürgen Hennig
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

6.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

7.  On the SAR and field inhomogeneity of birdcage coils loaded with the human head.

Authors:  J Jin; J Chen
Journal:  Magn Reson Med       Date:  1997-12       Impact factor: 4.668

8.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

9.  Magnetic resonance angiography.

Authors:  C L Dumoulin; H R Hart
Journal:  Radiology       Date:  1986-12       Impact factor: 11.105

10.  Spectroscopy and imaging with a 4 tesla whole-body MR system.

Authors:  H Bomsdorf; T Helzel; D Kunz; P Röschmann; O Tschendel; J Wieland
Journal:  NMR Biomed       Date:  1988-06       Impact factor: 4.044

View more
  16 in total

1.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

2.  Correction of parallel transmission using concurrent RF and gradient field monitoring.

Authors:  Mustafa Çavuşoğlu; Benjamin Emanuel Dietrich; David Otto Brunner; Markus Weiger; Klaas Paul Pruessmann
Journal:  MAGMA       Date:  2017-04-25       Impact factor: 2.310

3.  SIMULTANEOUSLY SPARSE SOLUTIONS TO LINEAR INVERSE PROBLEMS WITH MULTIPLE SYSTEM MATRICES AND A SINGLE OBSERVATION VECTOR.

Authors:  Adam C Zelinski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  SIAM J Sci Comput       Date:  2010-01-20       Impact factor: 2.373

4.  Parallel excitation for B-field insensitive fat-saturation preparation.

Authors:  Jeremiah A Heilman; Jamal D Derakhshan; Matthew J Riffe; Natalia Gudino; Jean Tkach; Chris A Flask; Jeffrey L Duerk; Mark A Griswold
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

5.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

Authors:  Sun Hao; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  IEEE Trans Med Imaging       Date:  2015-09-15       Impact factor: 10.048

Review 6.  Parallel Transmission for Ultrahigh Field MRI.

Authors:  Cem M Deniz
Journal:  Top Magn Reson Imaging       Date:  2019-06

7.  Small-tip-angle spokes pulse design using interleaved greedy and local optimization methods.

Authors:  William A Grissom; Mohammad-Mehdi Khalighi; Laura I Sacolick; Brian K Rutt; Mika W Vogel
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

8.  Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off-resonance.

Authors:  Daehyun Yoon; Jeffrey A Fessler; Anna C Gilbert; Douglas C Noll
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

9.  Four dimensional spectral-spatial fat saturation pulse design.

Authors:  Feng Zhao; Jon-Fredrik Nielsen; Douglas C Noll
Journal:  Magn Reson Med       Date:  2013-12-17       Impact factor: 4.668

10.  Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

Authors:  Sydney N Williams; Jon-Fredrik Nielsen; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2017-07-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.