Literature DB >> 9402197

On the SAR and field inhomogeneity of birdcage coils loaded with the human head.

J Jin1, J Chen.   

Abstract

Birdcage coils are widely used as a radiofrequency (RF) resonator in magnetic resonance imaging (MRI) because of their capability to produce a highly homogeneous B1 field over a large volume within the coil. When they are employed for high-frequency MRI, the interaction between the electromagnetic field and the object to be imaged deteriorates the B1-field homogeneity and increases the specific absorption rate (SAR) in the object. To investigate this problem, a finite-element method (FEM) is developed to analyze the SAR and the B1 field in a two-dimensional (2D) model of a birdcage coil loaded with a 2D model of a human head. The electric field, magnetic field, and SAR distributions are shown, and a comprehensive study is carried out for both linear and quadrature birdcage coils at 64, 128, 171, and 256 MHz. It is shown that to generate the same value of the B1 field, the SAR is increased significantly with the frequency, and for the same imaging method the SAR produced by a quadrature coil is significantly lower than that of a linear coil. It is also shown that the B1-field inhomogeneity is increased significantly with the frequency.

Entities:  

Mesh:

Year:  1997        PMID: 9402197     DOI: 10.1002/mrm.1910380615

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  MR imaging of RF heating using a paramagnetic doped agarose phantom.

Authors:  E M Shapiro; A Borthakur; R Reddy
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Fast MRI of RF heating via phase difference mapping.

Authors:  Erik M Shapiro; Arijitt Borthakur; Michael J Shapiro; Ravinder Reddy; John S Leigh
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

4.  Radiofrequency heating at 9.4T: in vivo temperature measurement results in swine.

Authors:  Devashish Shrivastava; Timothy Hanson; Robert Schlentz; William Gallaghar; Carl Snyder; Lance Delabarre; Surya Prakash; Paul Iaizzo; J Thomas Vaughan
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

5.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

6.  Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

Authors:  Adam C Zelinski; Lawrence L Wald; Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

7.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

8.  IMPULSE: A scalable algorithm for design of minimum specific absorption rate parallel transmit RF pulses.

Authors:  Mihir Pendse; Riccardo Stara; Mohammad Mehdi Khalighi; Brian Rutt
Journal:  Magn Reson Med       Date:  2018-11-13       Impact factor: 4.668

9.  Studies of RF Shimming Techniques with Minimization of RF Power Deposition and Their Associated Temperature Changes.

Authors:  Lin Tang; Yik-Kiong Hue; Tamer S Ibrahim
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-02       Impact factor: 1.176

Review 10.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

View more