Backside calibration chronopotentiometry: using current to perform ion measurements by zeroing the transmembrane ion flux.

Yida Xu1, Wittaya Ngeontae, Ernö Pretsch, Eric Bakker.   

Abstract

A recent new direction in ion-selective electrode (ISE) research utilizes a stir effect to indicate the disappearance of an ion concentration gradient across a thin ion-selective membrane. This zeroing experiment allows one to evaluate the equilibrium relationship between front and backside solutions contacting the membrane by varying the backside solution composition. This method is attractive since the absolute potential during the measurement is not required, thus avoiding standard recalibrations from the sample solution and a careful control of the reference electrode potential. We report here on a new concept to alleviate the need to continuously vary the composition of the backside solution. Instead, transmembrane ion fluxes are counterbalanced at an imposed critical current. A theoretical model illustrates the relationship between the magnitude of this critical current and the concentration of analyte and countertransporting ions and is found to correspond well with experimental results. The approach is demonstrated with lead(II)-selective membranes and protons as dominating interference ions, and the concentration of Pb(2+) was successfully measured in tap water samples. The principle was further evaluated with calcium-selective membranes and magnesium as counterdiffusing species, with good results. Advantages and limitations arising from the kinetic nature of the perturbation technique are discussed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18778039      PMCID: PMC2597783          DOI: 10.1021/ac800774e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  13 in total

1.  Picomolar detection limits with current-polarized Pb2+ ion-selective membranes.

Authors:  E Pergel; R E Gyurcsányi; K Tóth; E Lindner
Journal:  Anal Chem       Date:  2001-09-01       Impact factor: 6.986

2.  Ion-selective supported liquid membranes placed under steady-state diffusion control.

Authors:  Károly Tompa; Karin Birbaum; Adam Malon; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2005-12-01       Impact factor: 6.986

3.  Potentiometric sensors for trace-level analysis.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Trends Analyt Chem       Date:  2005-03       Impact factor: 12.296

4.  Backside calibration potentiometry: ion activity measurements with selective supported liquid membranes by calibrating from the inner side of the membrane.

Authors:  Adam Malon; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2007-01-15       Impact factor: 6.986

5.  Mathematical model of current-polarized ionophore-based ion-selective membranes.

Authors:  Justin M Zook; Richard P Buck; Jan Langmaier; Erno Lindner
Journal:  J Phys Chem B       Date:  2008-01-25       Impact factor: 2.991

6.  Beyond potentiometry: robust electrochemical ion sensor concepts in view of remote chemical sensing.

Authors:  Eric Bakker; Vishnupriya Bhakthavatsalam; Kebede L Gemene
Journal:  Talanta       Date:  2007-10-18       Impact factor: 6.057

7.  Sensitivity and working range of backside calibration potentiometry.

Authors:  Wittaya Ngeontae; Yida Xu; Chao Xu; Wanlapa Aeungmaitrepirom; Thawatchai Tuntulani; Ernö Pretsch; Eric Bakker
Journal:  Anal Chem       Date:  2007-10-12       Impact factor: 6.986

8.  Plasticized poly(vinyl chloride) properties and characteristics of valinomycin electrodes. Current-time responses to voltage steps.

Authors:  M L Iglehart; R P Buck; G Horvai; E Pungor
Journal:  Anal Chem       Date:  1988-05-15       Impact factor: 6.986

9.  Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS.

Authors:  A Ceresa; E Bakker; B Hattendorf; D Günther; E Pretsch
Journal:  Anal Chem       Date:  2001-01-15       Impact factor: 6.986

10.  Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit.

Authors:  Alan Ceresa; Aleksandar Radu; Shane Peper; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

View more
  2 in total

1.  Calibration-free Solid-State Ion-Selective Electrode Based on a Polarized PEDOT/PEDOT-S-Doped Copolymer as Back Contact.

Authors:  Christopher Bahro; Subir Goswami; Sarah Gernhart; Dipankar Koley
Journal:  Anal Chem       Date:  2022-06-03       Impact factor: 8.008

2.  Limitations of current polarization for lowering the detection limit of potentiometric polymeric membrane sensors.

Authors:  Lajos Höfler; Iwona Bedlechowicz; Tamás Vigassy; Róbert E Gyurcsányi; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.