Literature DB >> 12199570

Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit.

Alan Ceresa1, Aleksandar Radu, Shane Peper, Eric Bakker, Ernö Pretsch.   

Abstract

Submicromolar to picomolar lower detection limits have recently been obtained with various polymer membrane ion-selective electrodes by minimizing biases due to ion fluxes through the membrane. For the best performance, the compositions of the membrane and inner solution should be optimized for each application. Given the number of parameters to be adjusted, it has been difficult to find the best parameters for a target sample. In this paper, a much simplified and more practical steady-state model of zero-current ion fluxes is derived, which is based on measurable parameters. The model allows one to predict achievable lower detection limits for a membrane with given selectivities. It can also be used to predict the optimal composition of the inner filling solution for the measurement of samples with a known, typical ionic background. Selectivity coefficients of monovalent and divalent analyte ions required for desired detection limits in drinking water are calculated. As an application of the proposed general recipe, a silver-selective electrode is developed on the basis of the ionophore O,O''-bis[2-(methylthio)ethyl]-tert-butylcalix[4]arene. With the predicted optimal composition of the inner electrolyte, its lower detection limit is found to be 10(-9) M or 100 ppt Ag+ with an ionic background of 10(-5) M LiNO3, which is very close to the expected value.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12199570     DOI: 10.1021/ac025548y

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  29 in total

Review 1.  The new wave of ion-selective.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2002-08-01       Impact factor: 6.986

2.  Theory and Computer Simulation of the Time-Dependent Selectivity Behavior of Polymeric Membrane Ion-Selective Electrodes.

Authors:  W E Morf; E Pretsch; N F De Rooij
Journal:  J Electroanal Chem (Lausanne)       Date:  2008-03-15       Impact factor: 4.464

3.  Computer Simulation of Ion-Selective Membrane Electrodes and Related Systems by Finite-Element Procedures.

Authors:  W E Morf; E Pretsch; N F De Rooij
Journal:  J Electroanal Chem (Lausanne)       Date:  2007-04-01       Impact factor: 4.464

4.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes.

Authors:  Zsófia Szigeti; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Electroanalysis       Date:  2006-07-01       Impact factor: 3.223

5.  Improving the response behavior of Cd-selective polymeric membrane electrodes by incorporated lipophilic particles.

Authors:  Reto Thürer; Tamás Vigassy; Martina Hirayama; Ernö Pretsch
Journal:  Chem Analityczna       Date:  2006

6.  Potentiometry at trace levels in confined samples: ion-selective electrodes with subfemtomole detection limits.

Authors:  Adam Malon; Tamas Vigassy; Eric Bakker; Ernö Pretsch
Journal:  J Am Chem Soc       Date:  2006-06-28       Impact factor: 15.419

7.  Potentiometric sensors for trace-level analysis.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Trends Analyt Chem       Date:  2005-03       Impact factor: 12.296

8.  Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels.

Authors:  Karin Y Chumbimuni-Torres; Zong Dai; Nastassia Rubinova; Yun Xiang; Ernö Pretsch; Joseph Wang; Eric Bakker
Journal:  J Am Chem Soc       Date:  2006-10-25       Impact factor: 15.419

9.  Backside calibration potentiometry: ion activity measurements with selective supported liquid membranes by calibrating from the inner side of the membrane.

Authors:  Adam Malon; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2007-01-15       Impact factor: 6.986

10.  Potentiometric detection of DNA hybridization.

Authors:  Apon Numnuam; Karin Y Chumbimuni-Torres; Yun Xiang; Ralph Bash; Panote Thavarungkul; Proespichaya Kanatharana; Ernö Pretsch; Joseph Wang; Eric Bakker
Journal:  J Am Chem Soc       Date:  2007-12-20       Impact factor: 15.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.