Literature DB >> 17929899

Sensitivity and working range of backside calibration potentiometry.

Wittaya Ngeontae1, Yida Xu, Chao Xu, Wanlapa Aeungmaitrepirom, Thawatchai Tuntulani, Ernö Pretsch, Eric Bakker.   

Abstract

A new direction in potentiometric sensing, termed backside calibration potentiometry, was recently introduced. It makes use of the fact that the stir effect disappears in the absence of an ion-ionophore complex concentration gradient across supported liquid ion-selective membranes. This method is especially suitable for measurements in which recalibration in the sample is not feasible, such as in remote monitoring applications. Here, a theoretical model is established to predict the working concentration range of the method. Lead(II)-selective Celgard membranes were used here with H+ as the dominant interfering ions. The emf difference for stirred and unstirred solutions was measured, and the magnitude of this emf change as a function of the sample Pb2+ concentration was found to exhibit a bell shape that spans approximately 3 orders of magnitude. The concentration of interfering ions and the selectivity of the membrane were demonstrated to be important factors that affect the working range. Smaller ratios of primary ion concentrations at both aqueous sides of the membrane gave smaller emf difference values, and emf changes could still be observed with a logarithmic concentration ratio of 0.05. All experimental results correlated satisfactorily with the theoretical model.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17929899      PMCID: PMC2883727          DOI: 10.1021/ac071248a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  15 in total

1.  Tracing the history of selective ion sensors.

Authors:  R P Buck; E Lindner
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

2.  Rotating disk potentiometry for inner solution optimization of low-detection-limit ion-selective electrodes.

Authors:  Aleksandar Radu; Martin Telting-Diaz; Eric Bakker
Journal:  Anal Chem       Date:  2003-12-15       Impact factor: 6.986

3.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes.

Authors:  Zsófia Szigeti; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Electroanalysis       Date:  2006-07-01       Impact factor: 3.223

4.  Ion-selective supported liquid membranes placed under steady-state diffusion control.

Authors:  Károly Tompa; Karin Birbaum; Adam Malon; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2005-12-01       Impact factor: 6.986

5.  Potentiometry at trace levels in confined samples: ion-selective electrodes with subfemtomole detection limits.

Authors:  Adam Malon; Tamas Vigassy; Eric Bakker; Ernö Pretsch
Journal:  J Am Chem Soc       Date:  2006-06-28       Impact factor: 15.419

6.  Backside calibration potentiometry: ion activity measurements with selective supported liquid membranes by calibrating from the inner side of the membrane.

Authors:  Adam Malon; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2007-01-15       Impact factor: 6.986

7.  Selectivity of polymer membrane-based ion-selective electrodes: self-consistent model describing the potentiometric response in mixed ion solutions of different charge.

Authors:  E Bakker; R K Meruva; E Pretsch; M E Meyerhoff
Journal:  Anal Chem       Date:  1994-10-01       Impact factor: 6.986

8.  Neutral carrier based ion-selective electrode for the determination of total calcium in blood serum.

Authors:  P Anker; E Wieland; D Ammann; R E Dohner; R Asper; W Simon
Journal:  Anal Chem       Date:  1981-11       Impact factor: 6.986

9.  Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS.

Authors:  A Ceresa; E Bakker; B Hattendorf; D Günther; E Pretsch
Journal:  Anal Chem       Date:  2001-01-15       Impact factor: 6.986

10.  Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit.

Authors:  Alan Ceresa; Aleksandar Radu; Shane Peper; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

View more
  3 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

2.  Synthesis and Characterization of Organic-Inorganic Nanocomposite Poly-o-anisidine Sn(IV) Arsenophosphate: Its Analytical Applications as Pb(II) Ion-Selective Membrane Electrode.

Authors:  Asif Ali Khan; Umme Habiba; Anish Khan
Journal:  Int J Anal Chem       Date:  2009-08-09       Impact factor: 1.885

3.  Backside calibration chronopotentiometry: using current to perform ion measurements by zeroing the transmembrane ion flux.

Authors:  Yida Xu; Wittaya Ngeontae; Ernö Pretsch; Eric Bakker
Journal:  Anal Chem       Date:  2008-09-06       Impact factor: 6.986

  3 in total