Literature DB >> 35657169

Calibration-free Solid-State Ion-Selective Electrode Based on a Polarized PEDOT/PEDOT-S-Doped Copolymer as Back Contact.

Christopher Bahro1, Subir Goswami1, Sarah Gernhart1, Dipankar Koley1.   

Abstract

Solid-contact ion-selective electrodes (ISEs) have the inherent advantage of being miniaturized in addition to maintaining high selectivity and sensitivity of the ionophore-based ISE. The major disadvantage of ISEs is the necessity of performing a calibration curve (varying the intercept in the linear calibration curve equation) each time before running experiments, which limits their application as one-time disposable sensors or for use in remote water sample analysis. To overcome these challenges, we designed a unique back contact made of 3,4-ethylenedioxythiophene (EDOT) and 4-(2,3-dihydrothieno[3,4-b][1,4]dioxin-2-yl-methoxy)-1-butanesulfonic acid, sodium salt (EDOT-S). The calibration-free ISEs showed near Nernstian responses of 57.2 ± 0.2 mV/log [K+] and 28.5 ± 0.3 mV/log [Ca2+], while maintaining their respective selectivity against major interfering ions. The detection limits for Ca2+ and K+ ISEs were 0.45 ± 0.01 and 1.68 ± 0.18 μM, respectively. The charging cycles of the PEDOT: PEDOT-S back contact allowed us to fix the background potential at a desired fixed intercept value across different ionophores (K+, Ca2+). This protocol was used to determine the K+ and Ca2+ contents in creek water samples. The activity and concentration of [Ca2+] and [K+] in a local creek was found to be 257 ± 7.3 and 28.1 ± 1.1 μM, respectively.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35657169      PMCID: PMC9213238          DOI: 10.1021/acs.analchem.2c00748

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   8.008


  20 in total

1.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors.

Authors:  Philippe Bühlmann; Ernö Pretsch; Eric Bakker
Journal:  Chem Rev       Date:  1998-06-18       Impact factor: 60.622

2.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics.

Authors:  Eric Bakker; Philippe Bühlmann; Ernö Pretsch
Journal:  Chem Rev       Date:  1997-12-18       Impact factor: 60.622

3.  Ionophore-based ion-selective potentiometric and optical sensors.

Authors:  R Daniel Johnson; Leonidas G Bachas
Journal:  Anal Bioanal Chem       Date:  2003-05-07       Impact factor: 4.142

4.  A Chemical Approach to Optimizing Bioactive Glass Dental Composites.

Authors:  S Aponso; J G Ummadi; H Davis; J Ferracane; D Koley
Journal:  J Dent Res       Date:  2018-11-21       Impact factor: 6.116

5.  Advantages and limitations of reference electrodes with an ionic liquid junction and three-dimensionally ordered macroporous carbon as solid contact.

Authors:  Tiantian Zhang; Chun-Ze Lai; Melissa A Fierke; Andreas Stein; Philippe Bühlmann
Journal:  Anal Chem       Date:  2012-08-28       Impact factor: 6.986

6.  Calibration-free ionophore-based ion-selective electrodes with a Co(II)/Co(III) redox couple-based solid contact.

Authors:  Xu U Zou; Xue V Zhen; Jia H Cheong; Philippe Bühlmann
Journal:  Anal Chem       Date:  2014-08-20       Impact factor: 6.986

7.  Real-Time Metabolic Interactions between Two Bacterial Species Using a Carbon-Based pH Microsensor as a Scanning Electrochemical Microscopy Probe.

Authors:  Vrushali S Joshi; Partha S Sheet; Nyssa Cullin; Jens Kreth; Dipankar Koley
Journal:  Anal Chem       Date:  2017-09-29       Impact factor: 6.986

8.  Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range.

Authors:  Sergey Makarychev-Mikhailov; Alexey Shvarev; Eric Bakker
Journal:  Anal Chem       Date:  2006-04-15       Impact factor: 6.986

9.  Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 1. Galvanostatic pulse methods with decreased cycle time.

Authors:  Justin M Zook; Erno Lindner
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

10.  Backside calibration chronopotentiometry: using current to perform ion measurements by zeroing the transmembrane ion flux.

Authors:  Yida Xu; Wittaya Ngeontae; Ernö Pretsch; Eric Bakker
Journal:  Anal Chem       Date:  2008-09-06       Impact factor: 6.986

View more
  1 in total

1.  Carbon-Based Transducers for Solid-Contact Calcium Ion-Selective Electrodes: Mesopore and Nitrogen-Doping Effects.

Authors:  Yirong Zhang; Yitian Tang; Rongfeng Liang; Lijie Zhong; Jiexian Xu; Huici Lu; Xiaofeng Xu; Tingting Han; Yu Bao; Yingming Ma; Shiyu Gan; Li Niu
Journal:  Membranes (Basel)       Date:  2022-09-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.