Literature DB >> 18777025

MRI of respiratory dynamics with 2D steady-state free-precession and 2D gradient echo sequences at 1.5 and 3 Tesla: an observer preference study.

M Fabel1, B J Wintersperger, O Dietrich, M Eichinger, C Fink, M Puderbach, H-U Kauczor, S O Schoenberg, J Biederer.   

Abstract

To compare the image quality of dynamic lung MRI with variations of steady-state free-precession (SSFP) and gradient echo (GRE) cine techniques at 1.5 T and 3 T. Ventilated porcine lungs with simulated lesions inside a chest phantom and four healthy human subjects were assessed with SSFP (TR/TE=2.9/1.22 ms; 3 ima/s) and GRE sequences (TR/TE=2.34/0.96 ms; 8 ima/s) as baseline at 1.5 and 3 T. Modified SSFPs were performed with nine to ten images/s (parallel imaging factors 2 and 3). Image quality for representative structures and artifacts was ranked by three observers independently. At 1.5 T, standard SSFP achieved the best image quality with superior spatial resolution and signal, but equal temporal resolution to GRE. SSFP with improved temporal resolution was ranked second best. Further acceleration (PI factor 3) was of no benefit, but increased artifacts. At 3 T, GRE outranged SSFP imaging with high lesion signal intensity, while artifacts on SSFP images increased visibly. At 1.5 T, a modified SSFP with moderate parallel imaging (PI factor 2) was considered the best compromise of temporal and spatial resolution. At 3 T, GRE sequences remain the best choice for dynamic lung MRI.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18777025     DOI: 10.1007/s00330-008-1148-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  MR imaging of pneumonia in immunocompromised patients: comparison with helical CT.

Authors:  C C Leutner; J Gieseke; G Lutterbey; C K Kuhl; A Glasmacher; E Wardelmann; A Theisen; H H Schild
Journal:  AJR Am J Roentgenol       Date:  2000-08       Impact factor: 3.959

2.  [Detection of pulmonary nodules with breath-hold magnetic resonance imaging in comparison with computed tomography].

Authors:  J F Schäfer; J Vollmar; F Schick; M D Seemann; P Kamm; B Erdtmann; C D Claussen
Journal:  Rofo       Date:  2005-01

3.  Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.

Authors:  Matthias Gutberlet; Kerstin Schwinge; Patrick Freyhardt; Birgit Spors; Matthias Grothoff; Timm Denecke; Lutz Lüdemann; Ralph Noeske; Thoralf Niendorf; Roland Felix
Journal:  Eur Radiol       Date:  2005-05-05       Impact factor: 5.315

4.  Therapy monitoring using dynamic MRI: analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy.

Authors:  Christian Plathow; Holger Hof; Sabine Kuhn; Michael Puderbach; Sebastian Ley; Juergen Biederer; Claus D Claussen; Peter E Huber; Juergen Schaefer; Siegfried Tuengerthal; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2006-04-21       Impact factor: 5.315

5.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

6.  [Thoracic real-time MRI: experience from 2200 examinations in acute and ill-defined thoracic diseases].

Authors:  A Kluge; T Gerriets; C Müller; O Ekinci; T Neumann; T Dill; G Bachmann
Journal:  Rofo       Date:  2005-11

7.  Initial experience with lung-MRI at 3.0T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity.

Authors:  G Lutterbey; C Grohé; J Gieseke; M von Falkenhausen; N Morakkabati; M P Wattjes; R Manka; D Trog; H H Schild
Journal:  Eur J Radiol       Date:  2006-10-10       Impact factor: 3.528

8.  Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease.

Authors:  G Lutterbey; J Gieseke; M von Falkenhausen; N Morakkabati; H Schild
Journal:  Eur Radiol       Date:  2004-11-23       Impact factor: 5.315

9.  Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology.

Authors:  Gerald Antoch; Florian M Vogt; Lutz S Freudenberg; Fridun Nazaradeh; Susanne C Goehde; Jörg Barkhausen; Gerlinde Dahmen; Andreas Bockisch; Jörg F Debatin; Stefan G Ruehm
Journal:  JAMA       Date:  2003-12-24       Impact factor: 56.272

10.  Cardiac cine MR-imaging at 3T: FLASH vs SSFP.

Authors:  Damian J Tyler; Lucy E Hudsmith; Steffen E Petersen; Jane M Francis; Peter Weale; Stefan Neubauer; Kieran Clarke; Matthew D Robson
Journal:  J Cardiovasc Magn Reson       Date:  2006       Impact factor: 5.364

View more
  8 in total

1.  Four-dimensional magnetic resonance imaging using axial body area as respiratory surrogate: initial patient results.

Authors:  Juan Yang; Jing Cai; Hongjun Wang; Zheng Chang; Brian G Czito; Mustafa R Bashir; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-01-17       Impact factor: 7.038

2.  Evaluation of motion measurement using cine MRI for image guided stereotactic body radiotherapy on a new phantom platform.

Authors:  Zheng Chang; Jing Cai; Ziheng Wang; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2011

3.  Effects of Incentive Spirometry on Respiratory Motion in Healthy Subjects Using Cine Breathing Magnetic Resonance Imaging.

Authors:  Toshiaki Kotani; Tsutomu Akazawa; Tsuyoshi Sakuma; Shigeyuki Nagaya; Masaru Sonoda; Yuji Tanaka; Takehide Katogi; Tetsuharu Nemoto; Shohei Minami
Journal:  Ann Rehabil Med       Date:  2015-06-30

Review 4.  Assessment of Heterogeneity in Lung Structure and Function During Mechanical Ventilation: A Review of Methodologies.

Authors:  Jacob Herrmann; Michaela Kollisch-Singule; Joshua Satalin; Gary F Nieman; David W Kaczka
Journal:  J Eng Sci Med Diagn Ther       Date:  2022-05-11

Review 5.  [Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI].

Authors:  J Biederer; C Hintze; M Fabel; J Dinkel
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

6.  MRI of the lung (2/3). Why … when … how?

Authors:  J Biederer; M Beer; W Hirsch; J Wild; M Fabel; M Puderbach; E J R Van Beek
Journal:  Insights Imaging       Date:  2012-02-13

7.  Retracted: Reducing motion artifacts in 4D MR images using principal component analysis (PCA) combined with linear polynomial fitting model.

Authors:  Juan Yang; Hongjun Wang; Yong Yin; Dengwang Li
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study.

Authors:  Martin F Fast; Björn Eiben; Martin J Menten; Andreas Wetscherek; David J Hawkes; Jamie R McClelland; Uwe Oelfke
Journal:  Radiother Oncol       Date:  2017-10-10       Impact factor: 6.280

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.