Literature DB >> 29296304

Evaluation of motion measurement using cine MRI for image guided stereotactic body radiotherapy on a new phantom platform.

Zheng Chang1, Jing Cai1, Ziheng Wang1, Fang-Fang Yin1.   

Abstract

The objective of this study is to investigate accuracy of motion tracking of cine magnetic resonance imaging (MRI) for image-guided stereotactic body radiotherapy. A phantom platform was developed in this work to fulfill the goal. The motion phantom consisted of a platform, a solid thread, a motor and a control system that can simulate motion in various modes. To validate its reproducibility, the phantom platform was setup three times and imaged with fluoroscopy using an electronic portal imaging device (EPID) for the same motion profile. After the validation test, the phantom platform was evaluated using cine MRI at 2.5 frames/second on a 1.5T GE scanner using five different artificial profiles and five patient profiles. The above profiles were again measured with EPID fluoroscopy and used as references. Discrepancies between measured profiles from cine MRI and EPID were quantified using root-mean-square (RMS) and standard deviation (SD). Pearson's product moment correlational analysis was used to test correlation. The standard deviation for the reproducibility test was 0.28 mm. The discrepancies (RMS) between all profiles measured by cine MRI and EPID fluoroscopy ranged from 0.30 to 0.49 mm for artificial profiles and ranged from 0.75 to 0.91 mm for five patient profiles. The cine MRI sequence could precisely track phantom motion and the proposed motion phantom was feasible to evaluate cine MRI accuracy.

Entities:  

Keywords:  IGRT; cine MRI; fluoroscopy; motion phantom; motion tracking

Year:  2011        PMID: 29296304      PMCID: PMC5675467     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  25 in total

1.  An analysis of chest wall and diaphragm motions in patients with idiopathic scoliosis using dynamic breathing MRI.

Authors:  Toshiaki Kotani; Shohei Minami; Kazuhisa Takahashi; Keijiro Isobe; Yoshinori Nakata; Masashi Takaso; Masatoshi Inoue; Tetsuro Maruta; Tsutomu Akazawa; Takuya Ueda; Hideshige Moriya
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-01       Impact factor: 3.468

2.  The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator.

Authors:  Chen-Shou Chui; Ellen Yorke; Linda Hong
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

3.  Acquiring 4D thoracic CT scans using a multislice helical method.

Authors:  P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

4.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI.

Authors:  Christian Plathow; Sebastian Ley; Christian Fink; Michael Puderbach; Waldemar Hosch; Astrid Schmähl; Jürgen Debus; Hans-Ulrich Kauczor
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-07-15       Impact factor: 7.038

5.  Ultrasound-guided MRI: preliminary results using a motion phantom.

Authors:  Matthias Günther; David A Feinberg
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

6.  4D-Imaging of the lung: reproducibility of lesion size and displacement on helical CT, MRI, and cone beam CT in a ventilated ex vivo system.

Authors:  Juergen Biederer; Julien Dinkel; Gregor Remmert; Siri Jetter; Simeon Nill; Torsten Moser; Rolf Bendl; Carsten Thierfelder; Michael Fabel; Uwe Oelfke; Michael Bock; Christian Plathow; Hendrik Bolte; Thomas Welzel; Beata Hoffmann; Günter Hartmann; Wolfgang Schlegel; Jürgen Debus; Martin Heller; Hans-Ulrich Kauczor
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-01       Impact factor: 7.038

7.  Quantification of lung tumor volume and rotation at 3D dynamic parallel MR imaging with view sharing: preliminary results.

Authors:  Christian Plathow; Max Schoebinger; Christian Fink; Holger Hof; Jürgen Debus; Hans-Peter Meinzer; Hans-Ulrich Kauczor
Journal:  Radiology       Date:  2006-06-26       Impact factor: 11.105

8.  Ex-vivo injection technique for implanting solid pulmonary nodules into porcine lungs for multi-slice CT.

Authors:  H Bolte; S Müller-Hülsbeck; C Riedel; T Jahnke; N Inan; M Heller; J Biederer
Journal:  Rofo       Date:  2004-10

9.  Predicting respiratory motion for four-dimensional radiotherapy.

Authors:  S S Vedam; P J Keall; A Docef; D A Todor; V R Kini; R Mohan
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

10.  Phantom investigation of 3D motion-dependent volume aliasing during CT simulation for radiation therapy planning.

Authors:  James A Tanyi; Martin Fuss; Vladimir Varchena; Jack L Lancaster; Bill J Salter
Journal:  Radiat Oncol       Date:  2007-02-24       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.