Literature DB >> 18719885

[On the biomechanics of the hip: relevance of femoral anteversion for hip contact force and loading using a short-stemmed prostheses].

S W Tohtz1, M O Heller, W R Taylor, C Perka, G N Duda.   

Abstract

Short-stemmed hip implants were established in total hip arthroplasty in the last years. Also patients with secondary osteoarthritis of the hip with pathological anteversion of the femoral neck are treated increasingly using this method. Therefore an investigation was performed to analyze the resulting hip contact force and femoral loading in the proximal femur at the solid model of the "standardized femur". Two different situations of femoral component anteversion were simulated. Increased hip contact forces and an increase of medial and lateral cortex loads result in the anteverted model. With present level of knowledge about the influence of the hip contact force the use of short-stemmed implants is not uncritically in patients with degenerative osteoarthritis of the hip combined with rotational disorders of the proximal femur. The selection of the tribological pairing is to be considered more strongly regarding the wear behavior.

Entities:  

Mesh:

Year:  2008        PMID: 18719885     DOI: 10.1007/s00132-008-1318-1

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  20 in total

1.  [Short-stemmed endoprostheses in total hip arthroplasty].

Authors:  J Gulow; R Scholz; G Freiherr von Salis-Soglio
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

2.  Modular short-stem prosthesis in total hip arthroplasty: implant positioning and the influence of navigation.

Authors:  Arnim Braun; Djordje Lazovic; Rasmus Zigan
Journal:  Orthopedics       Date:  2007-10       Impact factor: 1.390

3.  Variability of femoral muscle attachments.

Authors:  G N Duda; D Brand; S Freitag; W Lierse; E Schneider
Journal:  J Biomech       Date:  1996-09       Impact factor: 2.712

4.  The sensitivity of muscle force predictions to changes in physiologic cross-sectional area.

Authors:  R A Brand; D R Pedersen; J A Friederich
Journal:  J Biomech       Date:  1986       Impact factor: 2.712

5.  The tradeoffs associated with modular hip prostheses.

Authors:  J P Collier; M B Mayor; I R Williams; V A Surprenant; H P Surprenant; B H Currier
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

6.  A conservative femoral replacement for total hip arthroplasty. A prospective study.

Authors:  B F Morrey; R A Adams; M Kessler
Journal:  J Bone Joint Surg Br       Date:  2000-09

7.  THA loading arising from increased femoral anteversion and offset may lead to critical cement stresses.

Authors:  Ralf U Kleemann; Markus O Heller; Ulrich Stoeckle; William R Taylor; Georg N Duda
Journal:  J Orthop Res       Date:  2003-09       Impact factor: 3.494

8.  Cementless CUT femoral neck prosthesis: increased rate of aseptic loosening after 5 years.

Authors:  Stephan Albrecht Ender; Andreas Machner; Geza Pap; Johannes Hubbe; Henning Grashoff; Hans-Wolfram Neumann
Journal:  Acta Orthop       Date:  2007-10       Impact factor: 3.717

9.  Tibio-femoral loading during human gait and stair climbing.

Authors:  William R Taylor; Markus O Heller; Georg Bergmann; Georg N Duda
Journal:  J Orthop Res       Date:  2004-05       Impact factor: 3.494

10.  Three-dimensional shape of the dysplastic femur: implications for THR.

Authors:  Philip C Noble; Emir Kamaric; Nobuhiko Sugano; Masaaki Matsubara; Yoshitada Harada; Kenji Ohzono; Vibor Paravic
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

View more
  1 in total

1.  The History of Biomechanics in Total Hip Arthroplasty.

Authors:  Jan Van Houcke; Vikas Khanduja; Christophe Pattyn; Emmanuel Audenaert
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.