Literature DB >> 17966020

Cementless CUT femoral neck prosthesis: increased rate of aseptic loosening after 5 years.

Stephan Albrecht Ender1, Andreas Machner, Geza Pap, Johannes Hubbe, Henning Grashoff, Hans-Wolfram Neumann.   

Abstract

BACKGROUND: Bone-saving hip arthroplasty techniques, which facilitate revision, are gaining importance as the number of hip replacements in younger patients increases. PATIENTS AND METHODS: 123 CUT femoral neck prostheses (ESKA Implants, Lübeck, Germany) were implanted in 113 patients (average age 53 years) between 1999 and 2002. After a mean follow-up of 5 (3-7) years, we determined the state of 120 prostheses; 3 patients could not be located. 97 patients with 107 prostheses, none of which had been revised, were evaluated clinically and radiographically.
RESULTS: The median Harris hip score improved from 51 points to 92 points in the unrevised hips. 13 CUT prostheses (11%) had been revised, 7 because of aseptic loosening, 3 because of persisting thigh pain, 1 because of immediate vertical migration, and 2 because of septic loosening. The 5-year survival rate of the CUT prosthesis was 89%.
INTERPRETATION: The medium-term survival with this type of femoral component is unsatisfactory, with a high rate of aseptic loosening. The surviving prostheses had a good clinical outcome.

Entities:  

Mesh:

Year:  2007        PMID: 17966020     DOI: 10.1080/17453670710014301

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  19 in total

1.  Two- to 4-Year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern.

Authors:  Richard L Amendola; Devon D Goetz; Steve S Liu; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

2.  CORR Insights®: Two- to 4-year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern.

Authors:  Christophe Nich
Journal:  Clin Orthop Relat Res       Date:  2016-08-09       Impact factor: 4.176

3.  [Periprosthetic femoral bone reaction after total hip arthroplasty with preservation of the collum femoris : CT-assisted osteodensitometry 1 and 3 years postoperatively].

Authors:  R Schmidt; S Gollwitzer; T E Nowak; M Nowak; L Häberle; A Kress; R Forst; L A Müller
Journal:  Orthopade       Date:  2011-07       Impact factor: 1.087

4.  Is mid-head resection a durable conservative option in the presence of poor femoral bone quality and distorted anatomy?

Authors:  Derek J W McMinn; Chandra Pradhan; Hena Ziaee; Joseph Daniel
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

5.  [Long-term results of thrust plate prostheses: comparison of patients younger than and older than 50 years].

Authors:  S Wienbeck; N Osada; E Basad; H Stürz; B A Ishaque
Journal:  Orthopade       Date:  2011-03       Impact factor: 1.087

6.  Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

Authors:  David Merschin; Richard Häne; Mersedeh Tohidnezhad; Thomas Pufe; Wolf Drescher
Journal:  Int Orthop       Date:  2018-03-22       Impact factor: 3.075

7.  Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients.

Authors:  Jonathan Hutt; Ziad Harb; Ian Gill; Fadhil Kashif; John Miller; Matthew Dodd
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

8.  [On the biomechanics of the hip: relevance of femoral anteversion for hip contact force and loading using a short-stemmed prostheses].

Authors:  S W Tohtz; M O Heller; W R Taylor; C Perka; G N Duda
Journal:  Orthopade       Date:  2008-09       Impact factor: 1.087

9.  [Total hip arthroplasty with the cementless spiron femoral neck prosthesis].

Authors:  A Lugeder; E Häring; A Müller; P Droste; P Dorste; J Zeichen
Journal:  Oper Orthop Traumatol       Date:  2013-08       Impact factor: 1.154

10.  5-year clinical and radiostereometric analysis (RSA) follow-up of 39 CUT femoral neck total hip prostheses in young osteoarthritis patients.

Authors:  Marc J Nieuwenhuijse; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717