Electronic cleansing (EC) is an emerging method for segmentation of fecal material in CT colonography (CTC) that is used for reducing or eliminating the requirement for cathartic bowel preparation and hence for improving patients' adherence to recommendations for colon cancer screening. In EC, feces tagged by an x-ray-opaque oral contrast agent are removed from the CTC images, effectively cleansing the colon after image acquisition. Existing EC approaches tend to suffer from the following cleansing artifacts: degradation of soft-tissue structures because of pseudo-enhancement caused by the surrounding tagged fecal materials, and pseudo soft-tissue structures and false fistulas caused by partial volume effects at the boundary between the air lumen and the tagged regions, called the air-tagging boundary (AT boundary). In this study, we developed a novel EC method, called structure-analysis cleansing, which effectively avoids these cleansing artifacts. In our method, submerged soft-tissue structures are recognized by their local morphologic signatures that are characterized based on the eigenvalues of a three-dimensional Hessian matrix. A structure-enhancement function is formulated for enhancing of the soft-tissue structures. In addition, thin folds sandwiched between the air lumen and tagged regions are enhanced by analysis of the local roughness based on multi-scale volumetric curvedness. Both values of the structure-enhancement function and the local roughness are integrated into the speed function of a level set method for delineating the tagged fecal materials. Thus, submerged soft-tissue structures as well as soft-tissue structures adhering to the tagged regions are preserved, whereas the tagged regions are removed along with the associated AT boundaries from CTC images. Evaluation of the quality of the cleansing based on polyps and folds in a colon phantom, as well as on polyps in clinical cathartic and noncathartic CTC cases with fluid and stool tagging, showed that our structure-analysis cleansing method is significantly superior to that of our previous thresholding-based EC method. It provides a cleansed colon with substantially reduced subtraction artifacts.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18697551      PMCID: PMC2809717          DOI: 10.1118/1.2936413

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images.

Authors:  Y Sato; S Nakajima; N Shiraga; H Atsumi; S Yoshida; T Koller; G Gerig; R Kikinis
Journal:  Med Image Anal       Date:  1998-06       Impact factor: 8.545

2.  Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps.

Authors:  H Yoshida; J Näppi
Journal:  IEEE Trans Med Imaging       Date:  2001-12       Impact factor: 10.048

3.  CT colonography without cathartic preparation: feasibility study.

Authors:  M R Callstrom; C D Johnson; J G Fletcher; J E Reed; D A Ahlquist; W S Harmsen; K Tait; L A Wilson; K E Corcoran
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

Review 4.  Electronic cleansing and stool tagging in CT colonography: advantages and pitfalls with primary three-dimensional evaluation.

Authors:  Perry J Pickhardt; Jong-Ho Richard Choi
Journal:  AJR Am J Roentgenol       Date:  2003-09       Impact factor: 3.959

5.  Digital subtraction bowel cleansing for CT colonography using morphological and linear filtration methods.

Authors:  Michael E Zalis; James Perumpillichira; Peter F Hahn
Journal:  IEEE Trans Med Imaging       Date:  2004-11       Impact factor: 10.048

6.  Dynamic-threshold level set method for volumetry of porcine kidney in CT images in vivo and ex vivo assessment of the accuracy of volume measurement.

Authors:  Wenli Cai; Nagaraj-Setty Holalkere; Gordon Harris; Dushyant Sahani; Hiroyuki Yoshida
Journal:  Acad Radiol       Date:  2007-07       Impact factor: 3.173

7.  A pyramid approach to subpixel registration based on intensity.

Authors:  P Thévenaz; U E Ruttimann; M Unser
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

8.  Polyp size at CT colonography after electronic subtraction cleansing in an anthropomorphic colon phantom.

Authors:  Michael E Zalis; James J Perumpillichira; John Y Kim; Chiara Del Frate; Cordula Magee; Peter F Hahn
Journal:  Radiology       Date:  2005-07       Impact factor: 11.105

9.  Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: prospective assessment of patient perceptions and preferences.

Authors:  Thomas M Gluecker; C Daniel Johnson; William S Harmsen; Kenneth P Offord; Ann M Harris; Lynn A Wilson; David A Ahlquist
Journal:  Radiology       Date:  2003-05       Impact factor: 11.105

10.  Patient preferences for CT colonography, conventional colonoscopy, and bowel preparation.

Authors:  Stephen L Ristvedt; Elizabeth G McFarland; Leonard B Weinstock; Eric P Thyssen
Journal:  Am J Gastroenterol       Date:  2003-03       Impact factor: 10.864

View more
  15 in total

Review 1.  Improving the accuracy of CTC interpretation: computer-aided detection.

Authors:  Ronald M Summers
Journal:  Gastrointest Endosc Clin N Am       Date:  2010-04

2.  Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection.

Authors:  Marius George Linguraru; Neil Panjwani; Joel G Fletcher; Ronald M Summers
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  The elephant in the room: bowel preparation for CT colonography.

Authors:  Ronald Summers
Journal:  Acad Radiol       Date:  2009-07       Impact factor: 3.173

4.  Electronic cleansing for dual-energy CT colonography based on material decomposition and virtual monochromatic imaging.

Authors:  Rie Tachibana; Janne J Näppi; Se Hyung Kim; Hiroyuki Yoshida
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-20

Review 5.  Informatics in radiology: dual-energy electronic cleansing for fecal-tagging CT colonography.

Authors:  Wenli Cai; Se Hyung Kim; June-Goo Lee; Hiroyuki Yoshida
Journal:  Radiographics       Date:  2013-03-11       Impact factor: 5.333

6.  Noncathartic CT colonography: Image quality assessment and performance and in a screening cohort.

Authors:  Joel G Fletcher; Alvin C Silva; Jeff L Fidler; Joseph G Cernigliaro; Armando Manduca; Paul J Limburg; Lynn A Wilson; Trudy A Engelby; Garrett Spencer; W Scott Harmsen; Jay Mandrekar; C Daniel Johnson
Journal:  AJR Am J Roentgenol       Date:  2013-10       Impact factor: 3.959

7.  Informatics in radiology: Electronic cleansing for noncathartic CT colonography: a structure-analysis scheme.

Authors:  Wenli Cai; Hiroyuki Yoshida; Michael E Zalis; Janne Johannes Näppi; Gordon J Harris
Journal:  Radiographics       Date:  2010-03-10       Impact factor: 5.333

8.  Matching 3-D prone and supine CT colonography scans using graphs.

Authors:  Shijun Wang; Nicholas Petrick; Robert L Van Uitert; Senthil Periaswamy; Zhuoshi Wei; Ronald M Summers
Journal:  IEEE Trans Inf Technol Biomed       Date:  2012-04-27

9.  Electronic cleansing for CT colonography: does it help CAD software performance in a high-risk population for colorectal cancer?

Authors:  Jae Yeon Wi; Se Hyung Kim; Jae Young Lee; Sang Gyun Kim; Joon Koo Han; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2010-03-23       Impact factor: 5.315

10.  Virtual tagging for laxative-free CT colonography: pilot evaluation.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.